Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.576
Filtrar
1.
PLoS One ; 19(7): e0304860, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38990930

RESUMO

Optimization tasks in diagnostic radiological imaging require objective quantitative metrics that correlate with the subjective perception of observers. However, although one such metric, the structural similarity index (SSIM), is popular, it has limitations across various aspects in its application to medical images. In this study, we introduce a novel image quality evaluation approach based on keypoints and their associated unique image feature values, focusing on developing a framework to address the need for robustness and interpretability that are lacking in conventional methodologies. The proposed index quantifies and visualizes the distance between feature vectors associated with keypoints, which varies depending on changes in the image quality. This metric was validated on images with varying noise levels and resolution characteristics, and its applicability and effectiveness were examined by evaluating images subjected to various affine transformations. In the verification of X-ray computed tomography imaging using a head phantom, the distances between feature descriptors for each keypoint increased as the image quality degraded, exhibiting a strong correlation with the changes in the SSIM. Notably, the proposed index outperformed conventional full-reference metrics in terms of robustness to various transformations which are without changes in the image quality. Overall, the results suggested that image analysis performed using the proposed framework could effectively visualize the corresponding feature points, potentially harnessing lost feature information owing to changes in the image quality. These findings demonstrate the feasibility of applying the novel index to analyze changes in the image quality. This method may overcome limitations inherent in conventional evaluation methodologies and contribute to medical image analysis in the broader domain.


Assuntos
Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Humanos , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
2.
Pediatrics ; 154(1)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38932710

RESUMO

Advanced imaging, including ultrasonography, computed tomography, and magnetic resonance imaging, is an integral component to the evaluation and management of ill and injured children in the emergency department. As with any test or intervention, the benefits and potential impacts on management must be weighed against the risks to ensure that high-value care is being delivered. There are important considerations specific to the pediatric patient related to the ordering and interpretation of advanced imaging. This policy statement provides guidelines for institutions and those who care for children to optimize the use of advanced imaging in the emergency department setting and was coauthored by experts in pediatric and general emergency medicine, pediatric radiology, and pediatric surgery. The intent is to guide decision-making where children may access care.


Assuntos
Serviço Hospitalar de Emergência , Humanos , Serviço Hospitalar de Emergência/normas , Criança , Imageamento por Ressonância Magnética/normas , Diagnóstico por Imagem/normas , Diagnóstico por Imagem/métodos , Tomografia Computadorizada por Raios X/normas , Ultrassonografia/métodos
3.
BMC Med ; 22(1): 267, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926820

RESUMO

BACKGROUND: Evidence from observational studies indicates that lung cancer screening (LCS) guidelines with high rates of lung cancer (LC) underdiagnosis, and although current screening guidelines have been updated and eligibility criteria for screening have been expanded, there are no studies comparing the efficiency of LCS guidelines in Chinese population. METHODS: Between 2005 and 2022, 31,394 asymptomatic individuals were screened using low-dose computed tomography (LDCT) at our institution. Demographic data and relevant LC risk factors were collected. The efficiency of the LCS for each guideline criteria was expressed as the efficiency ratio (ER). The inclusion rates, eligibility rates, LC detection rates, and ER based on the different eligibility criteria of the four guidelines were comparatively analyzed. The four guidelines were as follows: China guideline for the screening and early detection of lung cancer (CGSL), the National Comprehensive Cancer Network (NCCN), the United States Preventive Services Task Force (USPSTF), and International Early Lung Cancer Action Program (I-ELCAP). RESULTS: Of 31,394 participants, 298 (155 women, 143 men) were diagnosed with LC. For CGSL, NCCN, USPSTF, and I-ELCAP guidelines, the eligibility rates for guidelines were 13.92%, 6.97%, 6.81%, and 53.46%; ERe for eligibility criteria were 1.46%, 1.64%, 1.51%, and 1.13%, respectively; and for the inclusion rates, they were 19.0%, 9.5%, 9.3%, and 73.0%, respectively. LCs which met the screening criteria of CGSL, NCCN, USPSTF, and I-ELCAP guidelines were 29.2%, 16.4%, 14.8%, and 86.6%, respectively. The age and smoking criteria for CGSL were stricter, hence resulting in lower rates of LC meeting the screening criteria. The CGSL, NCCN, and USPSTF guidelines showed the highest underdiagnosis in the 45-49 age group (17.4%), while the I-ELCAP guideline displayed the highest missed diagnosis rate (3.0%) in the 35-39 age group. Males and females significantly differed in eligibility based on the criteria of the four guidelines (P < 0.001). CONCLUSIONS: The I-ELCAP guideline has the highest eligibility rate for both males and females. But its actual efficiency ratio for those deemed eligible by the guideline was the lowest. Whereas the NCCN guideline has the highest ERe value for those deemed eligible by the guideline.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico , Masculino , China , Feminino , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Pessoa de Meia-Idade , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/normas , Idoso , Guias de Prática Clínica como Assunto , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Adulto
4.
Intensive Care Med ; 50(7): 1096-1107, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38900283

RESUMO

PURPOSE: Application of standardised and automated assessments of head computed tomography (CT) for neuroprognostication after out-of-hospital cardiac arrest. METHODS: Prospective, international, multicentre, observational study within the Targeted Hypothermia versus Targeted Normothermia after out-of-hospital cardiac arrest (TTM2) trial. Routine CTs from adult unconscious patients obtained > 48 h ≤ 7 days post-arrest were assessed qualitatively and quantitatively by seven international raters blinded to clinical information using a pre-published protocol. Grey-white-matter ratio (GWR) was calculated from four (GWR-4) and eight (GWR-8) regions of interest manually placed at the basal ganglia level. Additionally, GWR was obtained using an automated atlas-based approach. Prognostic accuracies for prediction of poor functional outcome (modified Rankin Scale 4-6) for the qualitative assessment and for the pre-defined GWR cutoff < 1.10 were calculated. RESULTS: 140 unconscious patients were included; median age was 68 years (interquartile range [IQR] 59-76), 76% were male, and 75% had poor outcome. Standardised qualitative assessment and all GWR models predicted poor outcome with 100% specificity (95% confidence interval [CI] 90-100). Sensitivity in median was 37% for the standardised qualitative assessment, 39% for GWR-8, 30% for GWR-4 and 41% for automated GWR. GWR-8 was superior to GWR-4 regarding prognostic accuracies, intra- and interrater agreement. Overall prognostic accuracy for automated GWR (area under the curve [AUC] 0.84, 95% CI 0.77-0.91) did not significantly differ from manually obtained GWR. CONCLUSION: Standardised qualitative and quantitative assessments of CT are reliable and feasible methods to predict poor functional outcome after cardiac arrest. Automated GWR has the potential to make CT quantification for neuroprognostication accessible to all centres treating cardiac arrest patients.


Assuntos
Parada Cardíaca Extra-Hospitalar , Tomografia Computadorizada por Raios X , Humanos , Masculino , Estudos Prospectivos , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Parada Cardíaca Extra-Hospitalar/terapia , Parada Cardíaca Extra-Hospitalar/diagnóstico por imagem , Prognóstico , Hipotermia Induzida/métodos , Hipotermia Induzida/normas , Cabeça/diagnóstico por imagem , Valor Preditivo dos Testes
5.
J Cardiovasc Med (Hagerstown) ; 25(7): 473-487, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38829936

RESUMO

Cardiovascular magnetic resonance (CMR) and computed tomography (CCT) are advanced imaging modalities that recently revolutionized the conventional diagnostic approach to congenital heart diseases (CHD), supporting echocardiography and often replacing cardiac catheterization. This is the second of two complementary documents, endorsed by experts from the Working Group of the Italian Society of Pediatric Cardiology and the Italian College of Cardiac Radiology of the Italian Society of Medical and Interventional Radiology, aimed at giving updated indications on the appropriate use of CMR and CCT in different clinical CHD settings, in both pediatrics and adults. In this article, support is also given to radiologists, pediatricians, cardiologists, and cardiac surgeons for indications and appropriateness criteria for CMR and CCT in the most referred CHD, following the proposed new criteria presented and discussed in the first document. This second document also examines the impact of devices and prostheses for CMR and CCT in CHD and additionally presents some indications for CMR and CCT exams when sedation or narcosis is needed.


Assuntos
Consenso , Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/terapia , Itália , Tomografia Computadorizada por Raios X/normas , Cardiologia/normas , Imageamento por Ressonância Magnética/normas , Criança , Valor Preditivo dos Testes , Adulto , Sociedades Médicas/normas
6.
PLoS One ; 19(6): e0305474, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38875268

RESUMO

Finite element models built from quantitative computed tomography images rely on element-wise mapping of material properties starting from Hounsfield Units (HU), which can be converted into mineral densities upon calibration. While calibration is preferably carried out by scanning a phantom with known-density components, conducting phantom-based calibration may not always be possible. In such cases, a phantomless procedure, where the scanned subject's tissues are used as a phantom, is an interesting alternative. The aim of this study was to compare a phantom-based and a phantomless calibration method on 41 postmenopausal women. The proposed phantomless calibration utilized air, adipose, and muscle tissues, with reference equivalent mineral density values of -797, -95, and 38 mg/cm3, extracted from a previously performed phantom-based calibration. A 9-slice volume of interest (VOI) centred between the femoral head and knee rotation centres was chosen. Reference HU values for air, adipose, and muscle tissues were extracted by identifying HU distribution peaks within the VOI, and patient-specific calibration was performed using linear regression. Comparison of FE models calibrated with the two methods showed average relative differences of 1.99% for Young's modulus1.30% for tensile and 1.34% for compressive principal strains. Excellent correlations (R2 > 0.99) were identified for superficial maximum tensile and minimum compressive strains. Maximum normalised root mean square relative error (RMSRE) values settled at 4.02% for Young's modulus, 2.99% for tensile, and 3.22% for compressive principal strains, respectively. The good agreement found between the two methods supports the adoption of the proposed methodology when phantomless calibration is needed.


Assuntos
Fraturas do Quadril , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Humanos , Calibragem , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Feminino , Idoso , Fraturas do Quadril/diagnóstico por imagem , Densidade Óssea , Análise de Elementos Finitos , Simulação por Computador , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais
7.
Neuroimage ; 294: 120631, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38701993

RESUMO

INTRODUCTION: Spatial normalization is a prerequisite step for the quantitative analysis of SPECT or PET brain images using volume-of-interest (VOI) template or voxel-based analysis. MRI-guided spatial normalization is the gold standard, but the wide use of PET/CT or SPECT/CT in routine clinical practice makes CT-guided spatial normalization a necessary alternative. Ventricular enlargement is observed with aging, and it hampers the spatial normalization of the lateral ventricles and striatal regions, limiting their analysis. The aim of the present study was to propose a robust spatial normalization method based on CT scans that takes into account features of the aging brain to reduce bias in the CT-guided striatal analysis of SPECT images. METHODS: We propose an enhanced CT-guided spatial normalization pipeline based on SPM12. Performance of the proposed pipeline was assessed on visually normal [123I]-FP-CIT SPECT/CT images. SPM12 default CT-guided spatial normalization was used as reference method. The metrics assessed were the overlap between the spatially normalized lateral ventricles and caudate/putamen VOIs, and the computation of caudate and putamen specific binding ratios (SBR). RESULTS: In total 231 subjects (mean age ± SD = 61.9 ± 15.5 years) were included in the statistical analysis. The mean overlap between the spatially normalized lateral ventricles of subjects and the caudate VOI and the mean SBR of caudate were respectively 38.40 % (± SD = 19.48 %) of the VOI and 1.77 (± 0.79) when performing SPM12 default spatial normalization. The mean overlap decreased to 9.13 % (± SD = 1.41 %, P < 0.001) of the VOI and the SBR of caudate increased to 2.38 (± 0.51, P < 0.0001) when performing the proposed pipeline. Spatially normalized lateral ventricles did not overlap with putamen VOI using either method. The mean putamen SBR value derived from the proposed spatial normalization (2.75 ± 0.54) was not significantly different from that derived from the default SPM12 spatial normalization (2.83 ± 0.52, P > 0.05). CONCLUSION: The automatic CT-guided spatial normalization used herein led to a less biased spatial normalization of SPECT images, hence an improved semi-quantitative analysis. The proposed pipeline could be implemented in clinical routine to perform a more robust SBR computation using hybrid imaging.


Assuntos
Corpo Estriado , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Corpo Estriado/diagnóstico por imagem , Corpo Estriado/metabolismo , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Ventrículos Cerebrais/diagnóstico por imagem , Ventrículos Cerebrais/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Tropanos
8.
BMJ Open Qual ; 13(2)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38663928

RESUMO

INTRODUCTION: At Sandwell General Hospital, there was no risk stratification tool or pathway for head injury (HI) patients presenting to the emergency department (ED). This resulted in significant delays in the assessment of HI patients, compromising patient safety and quality of care. AIMS: To employ quality improvement methodology to design an effective adult HI pathway that: ensured >90% of high-risk HI patients being assessed by ED clinicians within 15 min of arrival, reduce CT turnaround times, and aiming to keep the final decision making <4 hours. METHODS: SWOT analysis was performed; driver diagrams were used to set out the aims and objectives. Plan-Do-Study-Act cycle was used to facilitate the change and monitor the outcomes. Process map was designed to identify the areas for improvement. A new HI pathway was introduced, imaging and transporting the patients was modified, and early decisions were made to meet the standards. RESULTS: Data were collected and monitored following the interventions. The new pathway improved the proportion of patients assessed by the ED doctors within 15 min from 31% to 63%. The average time to CT head scan was decreased from 69 min to 53 min. Average CT scan reporting time also improved from 98 min to 71 min. Overall, the average time to decision for admission or discharge decreased from 6 hours 48 min to 4 hours 24 min. CONCLUSIONS: Following implementation of the new HI pathway, an improvement in the patient safety and quality of care was noted. High-risk HI patients were picked up earlier, assessed quicker and had CT head scans performed sooner. Decision time for admission/discharge was improved. The HI pathway continues to be used and will be reviewed and re-audited between 3 and 6 months to ensure the sustained improvement.


Assuntos
Traumatismos Craniocerebrais , Serviço Hospitalar de Emergência , Melhoria de Qualidade , Humanos , Serviço Hospitalar de Emergência/organização & administração , Serviço Hospitalar de Emergência/estatística & dados numéricos , Traumatismos Craniocerebrais/terapia , Adulto , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tomografia Computadorizada por Raios X/normas , Masculino , Feminino
9.
Eur J Radiol ; 175: 111429, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38508091

RESUMO

The escalating use of Computed Tomography (CT) imaging necessitates establishment and periodic revision of Diagnostic Reference Levels (DRLs) to ensure patient protection optimization. This paper presents the outcomes of a national survey conducted from 2019 to 2022, focusing on revising DRLs for adult CT examinations. Dosimetric data from 127 scanners in 120 medical facilities, representing 25% of the country's CT scanners, were collected, emphasizing geographic distribution and technology representation. Τhe parameters used for DRLs were the CTDIvol and the DLP of a typical acquisition of the region of interest (scan DLP). In addition to the 7 CT examination for which the DRL values were revised, establishment of DRLs for neck, cervical spine, pelvic bones-hips, coronary artery calcium (Ca) score and cardiac computed tomography angiography (CCTA) examinations was performed. Revised DRLs exhibited a 15 % average decrease in CTDIvol and a 7 % average decrease in scan DLP from the initial DRLs. This reduction of dosimetric values is relatively low compared to other national studies. The findings revealed wide variations in dosimetric values and scan lengths among scanners, emphasizing the need for standardization and optimization. Incorporation of advanced technologies like Iterative Reconstruction (IR) showcased potential for further dose reduction, yet challenges in uniform implementation persist. The study underscores the importance of ongoing optimisation efforts, particularly in the context of increased CT utilization and evolving technology. The revised DRLs have been officially adopted in Greece, emphasizing the commitment to safe and effective CT practices.


Assuntos
Níveis de Referência de Diagnóstico , Doses de Radiação , Proteção Radiológica , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/normas , Tomografia Computadorizada por Raios X/métodos , Grécia , Proteção Radiológica/normas , Proteção Radiológica/métodos , Adulto
10.
Radiat Prot Dosimetry ; 200(7): 700-706, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38555500

RESUMO

In this study, an evaluation of the compliance test data from 684 computed tomography (CT)-scanners in Indonesia for the 2019-22 test period was carried out. The study was aimed to describe the performance profile of CT-scanners in Indonesia and evaluate the testing protocol. A total of 87.8% of the CT-scanners unconditionally passed the tests, 8.8% passed the tests with conditions and 3.4% failed the tests. Of the devices conditionally passed the tests, the top two causes were water CT number accuracy (45.2%) and laser position accuracy (41.9%). Meanwhile, 75.0% of the failed devices were due to failing to meet the patient dose test criteria. The failure of the test for the water CT number accuracy parameter was caused by variations in the type of phantom used in the test, where several types of phantoms did not use water as material of the homogeneity module. Failures in laser position accuracy test were caused by the passing criteria that adjust to the minimum slice thickness, so that modern CT-scanner with small detector sizes and collimations tend not to pass. On the other hand, the failure on dose aspects was due to the frequent unavailability of baseline values for comparison. Of these top three failure causes, two of them, namely the CT number and dose test parameters, have been accommodated in the latest regulation (BAPETEN Regulation No. 2/2022) with a change in the evaluation method, while for the laser position accuracy test it is recommended to alter the passing criteria to an absolute value, namely 1 mm.


Assuntos
Imagens de Fantasmas , Doses de Radiação , Tomógrafos Computadorizados , Indonésia , Humanos , Tomógrafos Computadorizados/normas , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas
11.
Radiography (Lond) ; 30(3): 821-826, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520958

RESUMO

INTRODUCTION: The National Institute for Health and Care Excellence (NICE) recommends that GPs initially refer patients with suspected lung cancer for a chest X-ray (CXR). The Radiology department has a 'fast track system' to identify those patients who may have lung cancer on CXR and are referred for a CT thorax with contrast to help determine a cancer diagnosis. This fast track system was put in place to ensure the NICE guidelines and NHS England's standards on a faster cancer diagnosis are being met. This audit studied the ability of radiologists and reporting radiographers to identify lung cancer on CXRs and the accuracy of the fast-track system. METHODS: 846 cases with lung alerts were analysed and 545 CXRs were audited. The CXRs were split into images reported by radiologists (168) and those reported by reporting radiographers (377). CT thorax results were collected through PACS and Cerner computer systems to identify if the 'fast track' system had yielded a "positive", "negative", or "other findings" result for lung cancer. RESULTS: 32.8% (179) of CXRs flagged for lung cancer were positive, 40.6% (221) were negative, and 26.6% (145) had other findings. Chi square statistical test showed no significant difference (p = 0.14) between the two reporting groups in their ability to identify lung cancer on CXRs. 27% (38) of CXRs flagged by radiologists and 35% (125) by reporting radiographers were positive for lung cancer. CONCLUSION: This clinical audit indicates, reporting radiographers and radiologists are not statistically significantly different regarding their ability to identify lung cancer on CXRs, when supported by the fast track system. The fast-track system had a 59.4 % accuracy rate, detected by the number of imaging of reports that identified a serious pathology. This concludes that the system is performing well, yet could still be improved. IMPLICATIONS FOR PRACTICE: This audit provides further evidence for the value of developing and deploying reporting radiographers for projection radiography reporting.


Assuntos
Neoplasias Pulmonares , Radiografia Torácica , Radiologistas , Encaminhamento e Consulta , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Radiografia Torácica/normas , Radiologistas/normas , Tomografia Computadorizada por Raios X/normas , Medicina Estatal , Feminino , Masculino , Reino Unido , Competência Clínica , Idoso , Pessoa de Meia-Idade , Inglaterra
12.
Childs Nerv Syst ; 40(6): 1873-1879, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38393384

RESUMO

BACKGROUND: Intracranial volume (ICV) is an important indicator of the development of the brain and skull in children. At present, there is a lack of ICV growth standards based on large infant and children samples. Our aim was to assess the normal range of the ICV variation in Russian children using a modern automatic system for constructing the endocranial cavity (Endex) and to provide growth standards of the ICV for clinical practice. METHODS: High-resolution head CT scans were obtained from 673 apparently healthy children (380 boys and 293 girls) aged 0-17 years and transformed into the ICV estimates using the Endex software. The open-source software RefCurv utilizing R and the GAMLSS add-on package with the LMS method was then used for the construction of smooth centile growth references for ICV according to age and sex. RESULTS: We demonstrated that the ICVs estimates calculated using the Endex software are perfectly comparable with those obtained by a conventional technique (i.e. seed feeling). Sex-specific pediatric growth charts for ICV were constructed. CONCLUSIONS: This study makes available for use in clinical practice ICV growth charts for the age from 0 to 17 based on a sample of 673 high-resolution CT images.


Assuntos
Encéfalo , Tomografia Computadorizada por Raios X , Humanos , Criança , Lactente , Pré-Escolar , Masculino , Feminino , Adolescente , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Recém-Nascido , Valores de Referência , Encéfalo/diagnóstico por imagem , Encéfalo/crescimento & desenvolvimento , Software , Crânio/diagnóstico por imagem , Crânio/anatomia & histologia , Tamanho do Órgão
13.
Neurol Sci ; 45(7): 3245-3253, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38285327

RESUMO

BACKGROUND AND OBJECTIVES: ASPECTs is a widely used marker to identify early stroke signs on non-enhanced computed tomography (NECT), yet it presents interindividual variability and it may be hard to use for non-experts. We introduce an algorithm capable of automatically estimating the NECT volumetric extension of early acute ischemic changes in the 3D space. We compared the power of this marker with ASPECTs evaluated by experienced practitioner in predicting the clinical outcome. METHODS: We analyzed and processed neuroimaging data of 153 patients admitted with acute ischemic stroke. All patients underwent a NECT at admission and on follow-up. The developed algorithm identifies the early ischemic hypodense region based on an automatic comparison of the gray level in the images of the two hemispheres, assumed to be an approximate mirror image of each other in healthy patients. RESULTS: In the two standard axial slices used to estimate the ASPECTs, the regions identified by the algorithm overlap significantly with those identified by experienced practitioners. However, in many patients, the regions identified automatically extend significantly to other slices. In these cases, the volume marker provides supplementary and independent information. Indeed, the clinical outcome of patients with volume marker = 0 can be distinguished with higher statistical confidence than the outcome of patients with ASPECTs = 10. CONCLUSION: The volumetric extension and the location of acute ischemic region in the 3D-space, automatically identified by our algorithm, provide data that are mostly in agreement with the ASPECTs value estimated by expert practitioners, and in some cases complementary and independent.


Assuntos
Algoritmos , AVC Isquêmico , Tomografia Computadorizada por Raios X , Humanos , Masculino , Tomografia Computadorizada por Raios X/normas , Tomografia Computadorizada por Raios X/métodos , Feminino , Idoso , AVC Isquêmico/diagnóstico por imagem , Pessoa de Meia-Idade , Isquemia Encefálica/diagnóstico por imagem , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Acidente Vascular Cerebral/diagnóstico por imagem
14.
J Neurotrauma ; 41(11-12): 1323-1336, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38279813

RESUMO

Computed tomography (CT) is an important imaging modality for guiding prognostication in patients with traumatic brain injury (TBI). However, because of the specialized expertise necessary, timely and dependable TBI prognostication based on CT imaging remains challenging. This study aimed to enhance the efficiency and reliability of TBI prognostication by employing machine learning (ML) techniques on CT images. A retrospective analysis was conducted on the Collaborative European NeuroTrauma Effectiveness Research in TBI (CENTER-TBI) data set (n = 1016). An ML-driven binary classifier was developed to predict favorable or unfavorable outcomes at 6 months post-injury. The prognostic performance was assessed using the area under the curve (AUC) over fivefold cross-validation and compared with conventional models that depend on clinical variables and CT scoring systems. An external validation was performed using the Comparative Indian Neurotrauma Effectiveness Research in Traumatic Brain Injury (CINTER-TBI) data set (n = 348). The developed model achieved superior performance without the necessity for manual CT assessments (AUC = 0.846 [95% CI: 0.843-0.849]) compared with the model based on the clinical and laboratory variables (AUC = 0.817 [95% CI: 0.814-0.820]) and established CT scoring systems requiring manual interpretations (AUC = 0.829 [95% CI: 0.826-0.832] for Marshall and 0.838 [95% CI: 0.835-0.841] for International Mission for Prognosis and Analysis of Clinical Trials in TBI [IMPACT]). The external validation demonstrated the prognostic capacity of the developed model to be significantly better (AUC = 0.859 [95% CI: 0.857-0.862]) than the model using clinical variables (AUC = 0.809 [95% CI: 0.798-0.820]). This study established an ML-based model that provides efficient and reliable TBI prognosis based on CT scans, with potential implications for earlier intervention and improved patient outcomes.


Assuntos
Lesões Encefálicas Traumáticas , Aprendizado de Máquina , Tomografia Computadorizada por Raios X , Humanos , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Masculino , Feminino , Prognóstico , Adulto , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Estudos Retrospectivos , Adulto Jovem , Idoso , Adolescente
15.
J Xray Sci Technol ; 32(3): 725-734, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38189739

RESUMO

BACKGROUND: To reduce radiation dose and subsequent risks, several legislative documents in different countries describe the need for Diagnostic Reference Levels (DRLs). Spinal radiography is a common and high-dose examination. Therefore, the aim of this work was to establish the DRL for Computed Tomography (CT) examinations of the spine in healthcare institutions across Jordan. METHODS: Data was retrieved from the picture archiving and communications system (PACS), which included the CT Dose Index (CTDI (vol) ) and Dose Length Product (DLP). The median radiation dose values of the dosimetric indices were calculated for each site. DRL values were defined as the 75th percentile distribution of the median CTDI (vol)  and DLP values. RESULTS: Data was collected from 659 CT examinations (316 cervical spine and 343 lumbar-sacral spine). Of the participants, 68% were males, and the patients' mean weight was 69.7 kg (minimum = 60; maximum = 80, SD = 8.9). The 75th percentile for the DLP of cervical and LS-spine CT scans in Jordan were 565.2 and 967.7 mGy.cm, respectively. CONCLUSIONS: This research demonstrates a wide range of variability in CTDI (vol)  and DLP values for spinal CT examinations; these variations were associated with the acquisition protocol and highlight the need to optimize radiation dose in spinal CT examinations.


Assuntos
Doses de Radiação , Coluna Vertebral , Tomografia Computadorizada por Raios X , Humanos , Jordânia , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Coluna Vertebral/diagnóstico por imagem , Idoso , Benchmarking , Níveis de Referência de Diagnóstico , Adolescente , Adulto Jovem , Criança , Idoso de 80 Anos ou mais
16.
Diagn Interv Imaging ; 104(7-8): 359-367, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37061392

RESUMO

PURPOSE: The purpose of this study was to assess the performance of quantitative computed tomography (CT) imaging for detecting pancreatic fatty infiltration, using the results of histopathological analysis as reference. MATERIALS AND METHODS: Sixty patients who underwent pancreatic surgery for a pancreatic tumor between 2016 and 2019 were retrospectively included. There were 33 women and 27 men with a mean age of 56 ± 12 (SD) years (age range: 18-79 years). Patients with dilatation of the main pancreatic duct, chronic pancreatitis, or preoperative treatment were excluded to prevent any bias in the radiological-pathological correlation. Pancreatic fatty infiltration was recorded at pathology. Pancreatic surface lobularity, pancreatic attenuation, visceral fat area, and subcutaneous fat area were derived from preoperative CT images. The performance for the prediction of fatty infiltration was assessed using area under receiver operating characteristic curve (AUC) and backward binary logistic regression analysis. Results were validated in a separate cohort of 34 patients (17 women; mean age, 50 ± 14 [SD] years; age range: 18-73). RESULTS: A total of 28/60 (47%) and 17/34 (50%) patients had pancreatic fatty infiltration in the derivation and validation cohorts, respectively. In the derivation cohort, patients with pancreatic fatty infiltration had a significantly higher PSL (P < 0.001) and a lower pancreatic attenuation on both precontrast and portal venous phase images (P = 0.011 and 0.003, respectively), and higher subcutaneous fat area and visceral fat area (P = 0.010 and 0.007, respectively). Multivariable analysis identified pancreatic surface lobularity > 7.6 and pancreatic attenuation on portal venous phase images < 83.5 Hounsfield units as independently associated with fatty infiltration. The combination of these variables resulted in an AUC of 0.85 (95% CI: 0.74-0.95) and 0.83 (95% CI: 0.67-0.99) in the derivation and validation cohorts, respectively. CONCLUSION: CT-based quantitative imaging accurately predicts pancreatic fatty infiltration.


Assuntos
Fibrose Cística , Lipomatose , Pâncreas , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/normas , Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Área Sob a Curva , Fibrose Cística/diagnóstico por imagem , Lipomatose/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Padrões de Referência
17.
Phys Med Biol ; 68(6)2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36854190

RESUMO

Objective. Low-dose computed tomography (LDCT) denoising is an important problem in CT research. Compared to the normal dose CT, LDCT images are subjected to severe noise and artifacts. Recently in many studies, vision transformers have shown superior feature representation ability over the convolutional neural networks (CNNs). However, unlike CNNs, the potential of vision transformers in LDCT denoising was little explored so far. Our paper aims to further explore the power of transformer for the LDCT denoising problem.Approach. In this paper, we propose a Convolution-free Token2Token Dilated Vision Transformer (CTformer) for LDCT denoising. The CTformer uses a more powerful token rearrangement to encompass local contextual information and thus avoids convolution. It also dilates and shifts feature maps to capture longer-range interaction. We interpret the CTformer by statically inspecting patterns of its internal attention maps and dynamically tracing the hierarchical attention flow with an explanatory graph. Furthermore, overlapped inference mechanism is employed to effectively eliminate the boundary artifacts that are common for encoder-decoder-based denoising models.Main results. Experimental results on Mayo dataset suggest that the CTformer outperforms the state-of-the-art denoising methods with a low computational overhead.Significance. The proposed model delivers excellent denoising performance on LDCT. Moreover, low computational cost and interpretability make the CTformer promising for clinical applications.


Assuntos
Redes Neurais de Computação , Tomografia Computadorizada por Raios X , Artefatos , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Humanos
18.
J Comput Assist Tomogr ; 47(2): 199-204, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36790871

RESUMO

PURPOSE: Previous studies have pointed out that magnetic resonance- and fluorodeoxyglucose positron emission tomography-based radiomics had a high predictive value for the response of the neoadjuvant chemotherapy (NAC) in breast cancer by respectively characterizing tumor heterogeneity of the relaxation time and the glucose metabolism. However, it is unclear whether computed tomography (CT)-based radiomics based on density heterogeneity can predict the response of NAC. This study aimed to develop and validate a CT-based radiomics nomogram to predict the response of NAC in breast cancer. METHODS: A total of 162 breast cancer patients (110 in the training cohort and 52 in the validation cohort) who underwent CT scans before receiving NAC and had pathological response results were retrospectively enrolled. Grades 4 to 5 cases were classified as response to NAC. According to the Miller-Payne grading system, grades 1 to 3 cases were classified as nonresponse to NAC. Radiomics features were extracted, and the optimal radiomics features were obtained to construct a radiomics signature. Multivariate logistic regression was used to develop the clinical prediction model and the radiomics nomogram that incorporated clinical characteristics and radiomics score. We assessed the performance of different models, including calibration and clinical usefulness. RESULTS: Eight optimal radiomics features were obtained. Human epidermal growth factor receptor 2 status and molecular subtype showed statistical differences between the response group and the nonresponse group. The radiomics nomogram had more favorable predictive efficacy than the clinical prediction model (areas under the curve, 0.82 vs 0.70 in the training cohort; 0.79 vs 0.71 in the validation cohort). The Delong test showed that there are statistical differences between the clinical prediction model and the radiomics nomogram ( z = 2.811, P = 0.005 in the training cohort). The decision curve analysis showed that the radiomics nomogram had higher overall net benefit than the clinical prediction model. CONCLUSION: The radiomics nomogram based on CT radiomics signature and clinical characteristics has favorable predictive efficacy for the response of NAC in breast cancer.


Assuntos
Neoplasias da Mama , Biologia Computacional , Tomografia Computadorizada por Raios X , Biologia Computacional/normas , Tomografia Computadorizada por Raios X/normas , Terapia Neoadjuvante , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Valor Preditivo dos Testes , Estudos Retrospectivos , Modelos Estatísticos , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
19.
Eur J Radiol ; 161: 110734, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36842273

RESUMO

PURPOSE: To compare liver fat quantification between MRI and photon-counting CT (PCCT). METHOD: A cylindrical phantom with inserts containing six concentrations of oil (0, 10, 20, 30, 50 and 100%) and oil-iodine mixtures (0, 10, 20, 30 and 50% fat +3 mg/mL iodine) was imaged with a PCCT (NAEOTOM Alpha) and a 1.5 T MRI system (MR 450w, IDEAL-IQ sequence), using clinical parameters. An IRB-approved prospective clinical evaluation included 12 obese adult patients with known fatty liver disease (seven women, mean age: 61.5 ± 13 years, mean BMI: 30.3 ± 4.7 kg/m2). Patients underwent a same-day clinical MRI and PCCT of the abdomen. Liver fat fractions were calculated for four segments (I, II, IVa and VII) using in- and opposed-phase on MRI ((Meanin - Meanopp)/2*Meanin) and iodine-fat, tissue decomposition analysis in PCCT (Syngo.Via VB60A). CT and MRI Fat fractions were compared using two-sample t-tests with equal variance. Statistical analysis was performed using RStudio (Version1.4.1717). RESULTS: Phantom results showed no significant differences between the known fat fractions (P = 0.32) or iodine (P = 0.6) in comparison to PCCT-measured concentrations, and no statistically significant difference between known and MRI-measured fat fractions (P = 0.363). In patients, the mean fat signal fraction measured on MRI and PCCT was 13.1 ± 9.9% and 12.0 ± 9.0%, respectively, with an average difference of 1.1 ± 1.9% between the modalities (P = 0.138). CONCLUSION: First experience shows promising accuracy of liver fat fraction quantification for PCCT in obese patients. This method may improve opportunistic screening for CT in the future.


Assuntos
Tecido Adiposo , Fígado , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/normas , Imageamento por Ressonância Magnética/normas , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fígado/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Fígado Gorduroso/diagnóstico por imagem , Reprodutibilidade dos Testes
20.
IEEE Trans Med Imaging ; 42(4): 1210-1224, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36449587

RESUMO

Photoacoustic computed tomography (PACT) images optical absorption contrast by detecting ultrasonic waves induced by optical energy deposition in materials such as biological tissues. An ultrasonic transducer array or its scanning equivalent is used to detect ultrasonic waves. The spatial distribution of the transducer elements must satisfy the spatial Nyquist criterion; otherwise, spatial aliasing occurs and causes artifacts in reconstructed images. The spatial Nyquist criterion poses different requirements on the transducer elements' distributions for different locations in the image domain, which has not been studied previously. In this research, we elaborate on the location dependency through spatiotemporal analysis and propose a location-dependent spatiotemporal antialiasing method. By applying this method to PACT in full-ring array geometry, we effectively mitigate aliasing artifacts with minimal effects on image resolution in both numerical simulations and in vivo experiments.


Assuntos
Técnicas Fotoacústicas , Tomografia Computadorizada por Raios X , Artefatos , Análise Espaço-Temporal , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Mama/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Algoritmos , Técnicas Fotoacústicas/métodos , Técnicas Fotoacústicas/normas , Simulação por Computador , Imagens de Fantasmas , Feminino , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...