Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Acta Radiol ; 62(3): 322-328, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32493033

RESUMO

BACKGROUND: Vascular cooling effects are a well-known source for tumor recurrence in thermal in situ ablation techniques for hepatic malignancies. Microwave ablation (MWA) is an ablation technique to be considered in the treatment of malignant liver tumors. The impact of vascular cooling in MWA is still controversial. PURPOSE: To evaluate the influence of different intrahepatic vessel types, vessel sizes, and vessel-to-antenna-distances on MWA geometry in vivo. MATERIAL AND METHODS: Five MWAs (902-928 MHz) were performed with an energy input of 24.0 kJ in three porcine livers in vivo. MWA lesions were cut into 2-mm slices. The minimum and maximum radius of the ablation area was measured for each slice. Distances were measured from ablation center toward all adjacent hepatic vessels with a diameter of ≥1 mm and within a perimeter of 20 mm around the antenna. The respective vascular cooling effect relative to the maximum ablation radius was calculated. RESULTS: In total, 707 vessels (489 veins, 218 portal fields) were detected; 370 (76%) hepatic veins and 185 (85%) portal fields caused a cooling effect. Portal fields resulted in higher cooling effects (37%) than hepatic veins (26%, P < 0.01). No cooling effect could be observed in close proximity of vessels within the central ablation zone. CONCLUSION: Hepatic vessels influenced MWA zones and caused a distinct cooling effect. Portal fields resulted in more pronounced cooling effect than hepatic veins. No cooling effect was observed around vessels situated within the central white zone.


Assuntos
Artéria Hepática/efeitos da radiação , Veias Hepáticas/efeitos da radiação , Neoplasias Hepáticas/terapia , Micro-Ondas/uso terapêutico , Ablação por Radiofrequência , Animais , Modelos Animais de Doenças , Feminino , Neoplasias Hepáticas/patologia , Suínos
2.
Oncology ; 96(4): 192-199, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30650415

RESUMO

AIM: Prognosis of hepatocellular carcinoma (HCC) with macrovascular invasion (MVI) is extremely poor. However, proper therapeutic strategies have not been established yet. The purpose of this study is to identify the effects of external beam radiation therapy (EBRT) for MVI of HCC. METHODS: We have analyzed and evaluated 80 consecutive patients with HCC with MVI who underwent EBRT, and factors associated with enhanced survival in EBRT were evaluated by univariate and multivariate analysis. RESULTS: The local response rate of radiotherapy for the irradiated MVI was 66.2%. The time to progression of the irradiated MVI was 5.8 months. Univariate and multivariate analyses showed that the higher irradiation dose (over 45 Gy) and the irradiation location (hepatic vein tumor thrombus - HVTT) were significant factors associated with survival benefits of EBRT. The response of EBRT for HVTT was significantly superior to that for portal vein or bile duct tumor thrombus. CONCLUSION: We conclude that a multidisciplinary therapeutic strategy based on EBRT should be proactively selected in the treatment of advanced HCC with MVI.


Assuntos
Ductos Biliares Intra-Hepáticos/efeitos da radiação , Carcinoma Hepatocelular/radioterapia , Veias Hepáticas/efeitos da radiação , Neoplasias Hepáticas/radioterapia , Veia Porta/efeitos da radiação , Dosagem Radioterapêutica , Adulto , Idoso , Idoso de 80 Anos ou mais , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/patologia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Feminino , Veias Hepáticas/diagnóstico por imagem , Veias Hepáticas/patologia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Veia Porta/diagnóstico por imagem , Veia Porta/patologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Semin Radiat Oncol ; 21(4): 256-63, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21939854

RESUMO

The refinement of radiation therapy and radioembolization techniques has led to a resurgent interest in radiation-induced liver disease (RILD). The awareness of technical and clinical parameters that influence the chance of RILD is important to guide patient selection and toxicity minimization strategies. "Classic" RILD is characterized by anicteric ascites and hepatomegaly and is unlikely to occur after a mean liver dose of approximately 30 Gy in conventional fractionation. By maintaining a low mean liver dose and sparing a "critical volume" of liver from radiation, stereotactic delivery techniques allow for the safe administration of higher tumor doses. Caution must be exercised for patients with hepatocellular carcinoma or pre-existing liver disease (eg, Child-Pugh score of B or C) because they are more susceptible to RILD that can manifest in a nonclassic pattern. Although no pharmacologic interventions have yet been proven to mitigate RILD, preclinical research shows the potential for therapies targeting transforming growth factor-ß and for the transplantation of stem cells, hepatocytes, and liver progenitor cells as strategies that may restore liver function. Also, in the clinical setting of veno-occlusive liver disease after high-dose chemotherapy, agents with fibrinolytic and antithrombotic properties can reverse liver failure, suggesting a possible role in the setting of RILD.


Assuntos
Fígado/efeitos da radiação , Lesões por Radiação/fisiopatologia , Radioterapia/efeitos adversos , Relação Dose-Resposta à Radiação , Veias Hepáticas/fisiopatologia , Veias Hepáticas/efeitos da radiação , Humanos , Fígado/fisiopatologia , Lesões por Radiação/diagnóstico , Lesões por Radiação/prevenção & controle , Lesões por Radiação/terapia
5.
Cancer Radiother ; 14(4-5): 344-9, 2010 Jul.
Artigo em Francês | MEDLINE | ID: mdl-20598611

RESUMO

The liver is a large abdominal organ in the right hypondrium. Because of its anatomical situation, it is near many abdominal PTVs as well as some lower thoracic PVTs. The liver could also be at the same time the target (for irradiation of liver metastases or primary liver tumours) and organ at risk (OAR). Radiation-induced liver disease (RILD) is radiobiologically the normal tissue complication probability (NTCP), i.e., the clinical event limiting the total dose that could be delivered. This review describes radiobiological criteria justifying the NTCP data, and recommendations for conformal 3D radiotherapy and stereotactic liver irradiation.


Assuntos
Fígado/efeitos da radiação , Lesões por Radiação/epidemiologia , Tolerância a Radiação , Radioterapia/efeitos adversos , Colesterol/metabolismo , Glucose/metabolismo , Veias Hepáticas/anatomia & histologia , Veias Hepáticas/efeitos da radiação , Humanos , Lipídeos/fisiologia , Fígado/anatomia & histologia , Fígado/fisiologia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Metástase Neoplásica/radioterapia , Veia Porta/anatomia & histologia , Veia Porta/efeitos da radiação , Proteínas/metabolismo , Lesões por Radiação/diagnóstico por imagem , Cintilografia , Radiocirurgia/efeitos adversos , Radioterapia/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Veia Cava Inferior/anatomia & histologia , Veia Cava Inferior/efeitos da radiação
6.
J Gastrointest Surg ; 13(2): 334-40, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18937016

RESUMO

BACKGROUND: Microwave ablation (MWA) is postulated to have several advantages over other thermoablative modalities in the treatment of hepatic tumors. Herein, we use an in vivo porcine model to determine the effect of hepatic blood flow on a novel MWA applicator. METHODS: Four 100-kg pigs underwent hepatic MWA (2,450 MHz, 100 W, 4 min) using a 5.7-mm diameter applicator (Microsulis Americas, Sulis V) inserted near large intrahepatic blood vessels. Real-time monitoring was performed using 3, 5, and 12 MHz diagnostic ultrasound transducers. The ablated zones were sectioned for gross and histological processing. RESULTS: Ablation zones were uniform in shape and size (3-4 cm) and related to power deliver only. Gross and microscopic examination revealed direct extension of ablation zones to the margin of major hepatic blood vessels and occasionally beyond the intended target. Of note, a momentary acoustic white-out occurred around the probe at 25 +/- -1 s in every ablation. DISCUSSION: The Sulis V MWA applicator produced uniform zones of ablation that remain unaffected by convective heat loss. The applicator induced a reproducible but temporary event as seen by ultrasound. Further study is warranted to define the physics, benefits, limits, and clinical safety of this new MWA technology.


Assuntos
Ablação por Cateter/instrumentação , Artéria Hepática/efeitos da radiação , Veias Hepáticas/efeitos da radiação , Circulação Hepática/efeitos da radiação , Fígado/efeitos da radiação , Micro-Ondas , Animais , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/patologia , Veias Hepáticas/diagnóstico por imagem , Veias Hepáticas/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Modelos Animais , Monitorização Intraoperatória , Processamento de Sinais Assistido por Computador , Suínos , Ultrassonografia
7.
Hepatogastroenterology ; 51(58): 1148-50, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15239264

RESUMO

A 54-year-old man had received low anterior resection for rectal carcinoma and extended right hepatectomy for a metastatic liver tumor. One year later, imaging studies disclosed a metastatic liver tumor in segment 2 of the liver. The residual left hepatic vein was completely invaded by the tumor from the root of the hepatic vein to the confluence of several branches by intraoperative ultrasonography. To resect partial liver with the involved hepatic vein was deemed impossible. Microwave coagulation therapy was performed on the tumor and the involved hepatic vein, as we had established the safety of microwave irradiation to the main hepatic vein without interference of the hepatic venous flow in an experimental study. The patient remains well 40 months after the surgery without recurrent signs. The hepatic venous flow of the irradiated hepatic vein is maintained well according to serial examination of Doppler ultrasonography.


Assuntos
Carcinoma/radioterapia , Veias Hepáticas/efeitos da radiação , Neoplasias Hepáticas/radioterapia , Micro-Ondas/uso terapêutico , Carcinoma/diagnóstico por imagem , Carcinoma/secundário , Carcinoma/cirurgia , Hepatectomia , Veias Hepáticas/diagnóstico por imagem , Humanos , Período Intraoperatório , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Complicações Pós-Operatórias , Neoplasias Retais/patologia , Neoplasias Retais/cirurgia , Cirurgia Assistida por Computador , Resultado do Tratamento , Ultrassonografia
8.
J Am Coll Surg ; 191(2): 164-74, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10945360

RESUMO

BACKGROUND: Intratumoral ablative therapy is being used increasingly for the treatment of primary and secondary hepatic malignancies. The interstitial point-source photon radiosurgery system (PRS) is a novel ablative technique that uses radiation therapy similar in dosimetry to interstitial brachytherapy. STUDY DESIGN: To determine the feasibility, toxicity, and local tissue destructive capabilities of the PRS in the liver, preliminary studies in a nontumor-bearing canine model were examined. A 6-month survival study was conducted. Each animal received three radiation treatments, in the right, central, and left hepatic regions. Three low-dose treatments were delivered to each of six animals (group A), generating a 2.0-cm-diameter radiated sphere with a dose of 20 Gy at the lesion edge. Three high-dose treatments were delivered to each of six animals (group B), generating a 3.0-cm-diameter radiated sphere with 20 Gy at the lesion edge. RESULTS: The treatment reproducibly generated sharply demarcated hepatic ablative lesions proportional to the administered dose. Mean lesion diameter at 1 month was 1.6+/-0.2 cm in group A and 3.4+/-1.0 cm in group B. Lesion size was independent of intrahepatic location, including near vascular structures. PRS therapy, when applied to portal structures, resulted in hilar damage. Hilar damage appeared to be associated with arteriolar thrombosis and bile duct injury. Treatment of regions adjacent to large hepatic veins and the IVC was not associated with vessel thrombosis or stricture. CONCLUSIONS: PRS ablation is a generally well-tolerated method that results in consistent, well-demarcated, symmetric lesions of complete necrosis with minimal adjacent parenchymal injury. Application of such an approach for the treatment of liver tumors is promising.


Assuntos
Fígado/cirurgia , Radiocirurgia/métodos , Animais , Arteríolas/efeitos da radiação , Ductos Biliares Intra-Hepáticos/efeitos da radiação , Modelos Animais de Doenças , Cães , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Veias Hepáticas/efeitos da radiação , Fígado/irrigação sanguínea , Fígado/efeitos da radiação , Neoplasias Hepáticas/cirurgia , Fótons , Lesões Experimentais por Radiação/etiologia , Radiocirurgia/efeitos adversos , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Taxa de Sobrevida , Trombose/etiologia , Veia Cava Inferior/efeitos da radiação
9.
J Vasc Interv Radiol ; 10(7): 899-906, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10435708

RESUMO

PURPOSE: To evaluate the ability of 32phosphorus intraluminal irradiation to reduce pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt (TIPS). MATERIALS AND METHODS: TIPS were successfully placed in 11 swine with normal portal pressures. Six animals received 15.2 Gy intraluminal irradiation to the hepatic parenchyma and venous outflow tract at the time of TIPS placement with use of a NA32P-filled balloon angioplasty catheter. Five control animals underwent TIPS and balloon angioplasty with saline. All animals were followed up for 28 days, at which time percutaneous portography was performed, the animals were killed, and the tissue around the TIPS stent was processed for histologic analysis. Maximum pseudointimal hyperplasia as a percentage of estimated TIPS diameter was calculated for each animal. RESULTS: At the time of euthanasia, all five control TIPS and all but one irradiated TIPS were occluded. Histologic analysis demonstrated considerable variability in the degree of pseudointimal hyperplasia within each TIPS and between animals. No statistically significant difference was found in the maximum pseudointimal hyperplasia, measured as a percentage of stent radius, between control (80.2%+/-17.4%) and irradiated animals (69.2%+/-25.2%). CONCLUSIONS: Irradiation of TIPS with 15.2 Gy 32P delivered at the time of TIPS placement did not significantly improve TIPS patency or reduce the degree of pseudointimal hyperplasia in swine with normal portal pressures.


Assuntos
Veias Hepáticas/efeitos da radiação , Radioisótopos de Fósforo/uso terapêutico , Veia Porta/efeitos da radiação , Derivação Portossistêmica Transjugular Intra-Hepática , Angioplastia com Balão , Animais , Constrição Patológica/radioterapia , Veias Hepáticas/patologia , Hiperplasia , Fígado/patologia , Fígado/efeitos da radiação , Radioisótopos de Fósforo/administração & dosagem , Veia Porta/patologia , Portografia , Dosagem Radioterapêutica , Stents , Suínos , Túnica Íntima/patologia , Túnica Íntima/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...