Resultados 1 - 20 de 10.253
Filtrar
2.
J Spec Oper Med ; 24(2): 34-38, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38837173

RESUMO

INTRODUCTION: Maximizing the capabilities of available lowflow oxygen is key to providing adequate oxygen to prevent/treat hypoxemia and conserve oxygen. We designed a closed-circuit system that allows rebreathing of gases while scrubbing carbon dioxide (CO2) in conjunction with portable mechanical ventilators in a bench model. METHODS: We evaluated the system using two portable mechanical ventilators currently deployed by the Department of Defense-Zoll 731 and AutoMedx SAVe II-over a range of ventilator settings and lung models, using 1 and 3L/min low-flow oxygen into a reservoir bag. We measured peak inspired oxygen concentration (FiO2), CO2-absorbent life, gas temperature and humidity, and the effect of airway suctioning and ventilator disconnection on FiO2 on ground and at altitude. RESULTS: FiO2 was =0.9 across all ventilator settings and altitudes using both oxygen flows. CO2-absorbent life was >7 hours. Airway humidity range was 87%-97%. Mean airway temperature was 25.4°C (SD 0.5°C). Ten-second suctioning reduced FiO2 22%-48%. Thirtysecond ventilator disconnect reduced FiO2 29%-63% depending on oxygen flow used. CONCLUSION: Use of a rebreathing system with mechanical ventilation has the potential for oxygen conservation but requires diligent monitoring of inspired FiO2 and CO2 to avoid negative consequences.


Assuntos
Dióxido de Carbono , Desenho de Equipamento , Oxigênio , Ventiladores Mecânicos , Humanos , Dióxido de Carbono/análise , Oxigênio/administração & dosagem , Respiração Artificial/instrumentação , Umidade , Temperatura , Altitude
3.
Crit Care Explor ; 6(6): e1102, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38842419

RESUMO

BACKGROUND: Tracheostomy-related acquired pressure injuries (TRPIs) are one of the hospital-acquired conditions. We hypothesize that an uneven ventilator circuit load, leading to non-neutral tracheostomy tube positioning in the immediate post-tracheostomy period, leads to an increased incidence of TRPIs. Does switching the ventilator circuit load daily, in addition to standard post-tracheostomy care, lead to a decreased incidence of TRPIs? METHODS: This is a prospective quality improvement study. Study was conducted at two academic hospital sites within tertiary care hospitals at Emory University in different ICUs. Consecutive patients undergoing bedside percutaneous tracheostomy by the interventional pulmonary service were included. The flip the ventilator circuit (FLIC) protocol was designed and implemented in selected ICUs, with other ICUs as controls. RESULTS: Incidence of TRPI in intervention and control group were recorded at post-tracheostomy day 5. A total of 99 patients were included from October 22, 2019, to May 22, 2020. Overall, the total incidence of any TRPI was 23% at post-tracheostomy day 5. Incidence of stage I, stage II, and stages III-IV TRPIs at postoperative day 5 was 11%, 12%, and 0%, respectively. There was a decrease in the rate of skin breakdown in patients following the FLIC protocol when compared with standard of care (13% vs. 36%; p = 0.01). In a multivariable analysis, interventional group had decreased odds of developing TRPI (odds ratio, 0.32; 95% CI, 0.11-0.92; p = 0.03) after adjusting for age, albumin, body mass index, diabetes mellitus, and days in hospital before tracheostomy. CONCLUSIONS: The incidence of TRPIs within the first week following percutaneous tracheostomy is high. Switching the side of the ventilator circuit to evenly distribute load, in addition to standard bundled tracheostomy care, may decrease the overall incidence of TRPIs.


Assuntos
Úlcera por Pressão , Traqueostomia , Humanos , Traqueostomia/efeitos adversos , Traqueostomia/métodos , Traqueostomia/instrumentação , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Úlcera por Pressão/prevenção & controle , Úlcera por Pressão/etiologia , Úlcera por Pressão/epidemiologia , Incidência , Respiração Artificial/efeitos adversos , Melhoria de Qualidade , Unidades de Terapia Intensiva , Ventiladores Mecânicos/efeitos adversos
4.
Crit Care Explor ; 6(7): e1113, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38916647

RESUMO

CONTEXT: Amid the COVID-19 pandemic, this study delves into ventilator shortages, exploring simple split ventilation (SSV), simple differential ventilation (SDV), and differential multiventilation (DMV). The knowledge gap centers on understanding their performance and safety implications. HYPOTHESIS: Our hypothesis posits that SSV, SDV, and DMV offer solutions to the ventilator crisis. Rigorous testing was anticipated to unveil advantages and limitations, aiding the development of effective ventilation approaches. METHODS AND MODELS: Using a specialized test bed, SSV, SDV, and DMV were compared. Simulated lungs in a controlled setting facilitated measurements with sensors. Statistical analysis honed in on parameters like peak inspiratory pressure (PIP) and positive end-expiratory pressure. RESULTS: Setting target PIP at 15 cm H2O for lung 1 and 12.5 cm H2O for lung 2, SSV revealed a PIP of 15.67 ± 0.2 cm H2O for both lungs, with tidal volume (Vt) at 152.9 ± 9 mL. In SDV, lung 1 had a PIP of 25.69 ± 0.2 cm H2O, lung 2 at 24.73 ± 0.2 cm H2O, and Vts of 464.3 ± 0.9 mL and 453.1 ± 10 mL, respectively. DMV trials showed lung 1's PIP at 13.97 ± 0.06 cm H2O, lung 2 at 12.30 ± 0.04 cm H2O, with Vts of 125.8 ± 0.004 mL and 104.4 ± 0.003 mL, respectively. INTERPRETATION AND CONCLUSIONS: This study enriches understanding of ventilator sharing strategy, emphasizing the need for careful selection. DMV, offering individualization while maintaining circuit continuity, stands out. Findings lay the foundation for robust multiplexing strategies, enhancing ventilator management in crises.


Assuntos
COVID-19 , Respiração Artificial , Ventiladores Mecânicos , Humanos , Respiração Artificial/métodos , Respiração Artificial/instrumentação , Volume de Ventilação Pulmonar , SARS-CoV-2 , Respiração com Pressão Positiva/métodos , Respiração com Pressão Positiva/instrumentação
5.
PLoS One ; 19(5): e0303443, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753734

RESUMO

INTRODUCTION: During the COVID-19 pandemic, ventilator shortages necessitated the development of new, low-cost ventilator designs. The fundamental requirements of a ventilator include precise gas delivery, rapid adjustments, durability, and user-friendliness, often achieved through solenoid valves. However, few solenoid-valve assisted low-cost ventilator (LCV) designs have been published, and gas exchange evaluation during LCV testing is lacking. This study describes the development and performance evaluation of a solenoid-valve assisted low-cost ventilator (SV-LCV) in vitro and in vivo, focusing on gas exchange and respiratory mechanics. METHODS: The SV-LCV, a fully open ventilator device, was developed with comprehensive hardware and design documentation, utilizing solenoid valves for gas delivery regulation. Lung simulator testing calibrated tidal volumes at specified inspiratory and expiratory times, followed by in vivo testing in a porcine model to compare SV-LCV performance with a conventional ventilator. RESULTS: The SV-LCV closely matched the control ventilator's respiratory profile and gas exchange across all test cycles. Lung simulator testing revealed direct effects of compliance and resistance changes on peak pressures and tidal volumes, with no significant changes in respiratory rate. In vivo testing demonstrated comparable gas exchange parameters between SV-LCV and conventional ventilator across all cycles. Specifically, in cycle 1, the SV-LCV showed arterial blood gas (ABG) results of pH 7.54, PCO2 34.5 mmHg, and PO2 91.7 mmHg, compared to the control ventilator's ABG of pH 7.53, PCO2 37.1 mmHg, and PO2 134 mmHg. Cycle 2 exhibited ABG results of pH 7.53, PCO2 33.6 mmHg, and PO2 84.3 mmHg for SV-LCV, and pH 7.5, PCO2 34.2 mmHg, and PO2 93.5 mmHg for the control ventilator. Similarly, cycle 3 showed ABG results of pH 7.53, PCO2 32.1 mmHg, and PO2 127 mmHg for SV-LCV, and pH 7.5, PCO2 35.5 mmHg, and PO2 91.3 mmHg for the control ventilator. CONCLUSION: The SV-LCV provides similar gas exchange and respiratory mechanic profiles compared to a conventional ventilator. With a streamlined design and performance akin to commercially available ventilators, the SV-LCV presents a viable, readily available, and reliable short-term solution for overcoming ventilator supply shortages during crises.


Assuntos
COVID-19 , Troca Gasosa Pulmonar , Mecânica Respiratória , Ventiladores Mecânicos , Animais , Suínos , Desenho de Equipamento , Respiração Artificial/instrumentação , Respiração Artificial/métodos , SARS-CoV-2 , Volume de Ventilação Pulmonar
6.
PLoS One ; 19(5): e0297880, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38768181

RESUMO

INTRODUCTION: Hyperinflation is a common procedure to clear secretion, increase lung compliance and enhance oxygenation in mechanically ventilated patients. Hyperinflation can be provided as manual hyperinflation (MHI) or ventilator hyperinflation (VHI), where outcomes depend upon the methods of application. Hence it is crucial to assess the application of techniques employed in Sri Lanka due to observed variations from recommended practices. OBJECTIVE: This study is aimed to evaluate the application and parameters used for MHI and VHI by physiotherapists in intensive care units (ICUs) in Sri Lanka. METHODOLOGY: An online survey was conducted among physiotherapists who are working in ICUs in Sri Lanka using WhatsApp groups and other social media platforms. RESULTS: A total of 96 physiotherapists responded. The survey comprised of three sections to obtain information about socio-demographic data, MHI practices and VHI practices. Most of the respondents (47%) worked in general hospitals and 74% of participants had a bachelor's degree in physiotherapy; 31.3% had 3-6 years of experience; 93.8% used hyperinflation, and 78.9% used MHI. MHI was performed routinely and as needed to treat low oxygen levels, abnormal breath sounds, and per physician orders while avoiding contraindications. Self-inflation bags are frequently used for MHI (40.6%). Only a few participants (26%) used a manometer or tracked PIP. In addition to the supine position, some participants (37.5%) used the side-lying position. Most physiotherapists followed the recommended MHI technique: slow squeeze (57.3%), inspiratory pause (45.8%), and quick release (70.8%). VHI was practised by 19.8%, with medical approval and it was frequently performed by medical staff compared to physiotherapists. Treatment time, number of breaths, and patient positioning varied, and parameters were not well-defined. CONCLUSION: The study found that MHI was not applied with the recommended PIP, and VHI parameters were not identified. The study indicates a need to educate physiotherapists about current VHI and MHI practice guidelines.


Assuntos
Fisioterapeutas , Respiração Artificial , Humanos , Sri Lanka , Inquéritos e Questionários , Respiração Artificial/métodos , Masculino , Feminino , Adulto , Unidades de Terapia Intensiva , Cuidados Críticos/métodos , Ventiladores Mecânicos/estatística & dados numéricos
8.
J Clin Monit Comput ; 38(3): 679-690, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38557919

RESUMO

This study aims to resolve the unmet need for ventilator surge capacity by developing a prototype device that can alter patient-specific flow in a shared ventilator setup. The device is designed to deliver a predictable tidal volume (VT), requiring minimal additional monitoring and workload. The prototyped device was tested in an in vitro bench setup for its performance against the intended use and design criteria. The ventilation parameters: VT and airway pressures, and ventilation profiles: pressure, flow and volume were measured for different ventilator and device settings for a healthy and ARDS simulated lung pathology. We obtained VTs with a linear correlation with valve openings from 10 to 100% across set inspiratory pressures (IPs) of 20 to 30 cmH2O. Airway pressure varied with valve opening and lung elastance but did not exceed set IPs. Performance was consistent in both healthy and ARDS-simulated lung conditions. The ventilation profile diverged from traditional pressure-controlled profiles. We present the design a flow modulator to titrate VTs in a shared ventilator setup. Application of the flow modulator resulted in a characteristic flow profile that differs from pressure- or volume controlled ventilation. The development of the flow modulator enables further validation of the Individualized Shared Ventilation (ISV) technology with individualization of delivered VTs and the development of a clinical protocol facilitating its clinical use during a ventilator surge capacity problem.


Assuntos
Desenho de Equipamento , Pulmão , Respiração Artificial , Síndrome do Desconforto Respiratório , Volume de Ventilação Pulmonar , Ventiladores Mecânicos , Humanos , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/terapia , Síndrome do Desconforto Respiratório/fisiopatologia , Pulmão/fisiopatologia , Pressão
9.
Crit Care Med ; 52(7): 1021-1031, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38563609

RESUMO

OBJECTIVES: Nonconventional ventilators (NCVs), defined here as transport ventilators and certain noninvasive positive pressure devices, were used extensively as crisis-time ventilators for intubated patients with COVID-19. We assessed whether there was an association between the use of NCV and higher mortality, independent of other factors. DESIGN: This is a multicenter retrospective observational study. SETTING: The sample was recruited from a single healthcare system in New York. The recruitment period spanned from March 1, 2020, to April 30, 2020. PATIENTS: The sample includes patients who were intubated for COVID-19 acute respiratory distress syndrome (ARDS). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary outcome was 28-day in-hospital mortality. Multivariable logistic regression was used to derive the odds of mortality among patients managed exclusively with NCV throughout their ventilation period compared with the remainder of the sample while adjusting for other factors. A secondary analysis was also done, in which the mortality of a subset of the sample exclusively ventilated with NCV was compared with that of a propensity score-matched subset of the control group. Exclusive use of NCV was associated with a higher 28-day in-hospital mortality while adjusting for confounders in the regression analysis (odds ratio, 1.41; 95% CI [1.07-1.86]). In the propensity score matching analysis, the mortality of patients exclusively ventilated with NCV was 68.9%, and that of the control was 60.7% ( p = 0.02). CONCLUSIONS: Use of NCV was associated with increased mortality among patients with COVID-19 ARDS. More lives may be saved during future ventilator shortages if more full-feature ICU ventilators, rather than NCVs, are reserved in national and local stockpiles.


Assuntos
COVID-19 , Mortalidade Hospitalar , Síndrome do Desconforto Respiratório , Ventiladores Mecânicos , Humanos , COVID-19/terapia , COVID-19/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Síndrome do Desconforto Respiratório/terapia , Síndrome do Desconforto Respiratório/mortalidade , Ventiladores Mecânicos/provisão & distribuição , Ventiladores Mecânicos/estatística & dados numéricos , New York/epidemiologia , Respiração Artificial/estatística & dados numéricos
10.
Crit Care ; 28(1): 107, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566126

RESUMO

BACKGROUND: Pre-clinical studies suggest that dyssynchronous diaphragm contractions during mechanical ventilation may cause acute diaphragm dysfunction. We aimed to describe the variability in diaphragm contractile loading conditions during mechanical ventilation and to establish whether dyssynchronous diaphragm contractions are associated with the development of impaired diaphragm dysfunction. METHODS: In patients receiving invasive mechanical ventilation for pneumonia, septic shock, acute respiratory distress syndrome, or acute brain injury, airway flow and pressure and diaphragm electrical activity (Edi) were recorded hourly around the clock for up to 7 days. Dyssynchronous post-inspiratory diaphragm loading was defined based on the duration of neural inspiration after expiratory cycling of the ventilator. Diaphragm function was assessed on a daily basis by neuromuscular coupling (NMC, the ratio of transdiaphragmatic pressure to diaphragm electrical activity). RESULTS: A total of 4508 hourly recordings were collected in 45 patients. Edi was low or absent (≤ 5 µV) in 51% of study hours (median 71 h per patient, interquartile range 39-101 h). Dyssynchronous post-inspiratory loading was present in 13% of study hours (median 7 h per patient, interquartile range 2-22 h). The probability of dyssynchronous post-inspiratory loading was increased with reverse triggering (odds ratio 15, 95% CI 8-35) and premature cycling (odds ratio 8, 95% CI 6-10). The duration and magnitude of dyssynchronous post-inspiratory loading were associated with a progressive decline in diaphragm NMC (p < 0.01 for interaction with time). CONCLUSIONS: Dyssynchronous diaphragm contractions may impair diaphragm function during mechanical ventilation. TRIAL REGISTRATION: MYOTRAUMA, ClinicalTrials.gov NCT03108118. Registered 04 April 2017 (retrospectively registered).


Assuntos
Respiração Artificial , Síndrome do Desconforto Respiratório , Humanos , Diafragma , Respiração Artificial/efeitos adversos , Tórax , Ventiladores Mecânicos
11.
Cardiol Clin ; 42(2): 253-271, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38631793

RESUMO

This review aims to enhance the comprehension and management of cardiopulmonary interactions in critically ill patients with cardiovascular disease undergoing mechanical ventilation. Highlighting the significance of maintaining a delicate balance, this article emphasizes the crucial role of adjusting ventilation parameters based on both invasive and noninvasive monitoring. It provides recommendations for the induction and liberation from mechanical ventilation. Special attention is given to the identification of auto-PEEP (positive end-expiratory pressure) and other situations that may impact hemodynamics and patients' outcomes.


Assuntos
Emergências , Respiração Artificial , Humanos , Respiração com Pressão Positiva , Ventiladores Mecânicos , Pulmão
13.
Disaster Med Public Health Prep ; 18: e65, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38606429

RESUMO

OBJECTIVES: Future pandemics may cause more severe respiratory illness in younger age groups than COVID-19, requiring many more mechanical ventilators. This publication synthesizes the experiences of diverse contributors to Medtronic's mechanical ventilator supply chain during the pandemic, serving as a record of what worked and what didn't, while identifying key factors affecting production ramp-up in this healthcare crisis. METHOD: In-depth, one-on-one interviews (n = 17) were held with key Medtronic personnel and suppliers. Template analysis was used, and interview content was analyzed for signals, initiatives, actions, and outcomes, as well as influencing forces. RESULTS: Key findings revealed many factors limiting ventilator production ramp-up. Supply chain strengths and weaknesses were identified. Political factors played a role in allocating ventilators and also supported production. Commercial considerations were not priority, but economic awareness was essential to support suppliers. Workers were motivated and flexible. Component shortages, space, production processes, and logistics were challenges. Legally based pressures were reported e.g., import and export restrictions. CONCLUSION: Crisis response alone is not enough; preparation is essential. Coordinated international strategies are more effective than individual country responses. Supply chain resilience based on visibility and flexibility is key. This research can help public health planners and the medical device industry prepare for future healthcare crises.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias/prevenção & controle , Preparação para Pandemia , Saúde Pública , Ventiladores Mecânicos
14.
Nursing ; 54(5): 17-25, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38640027

RESUMO

ABSTRACT: Mechanical ventilation is rarely a simple matter. Skill and knowledge are required to operate the ventilator modes, choose the optimal settings, and understand many monitored variables. Supporting the patient safely and effectively is the top priority in providing mechanical ventilation. This article discusses mechanical ventilation in adults.


Assuntos
Respiração Artificial , Ventiladores Mecânicos , Adulto , Humanos
15.
Crit Care ; 28(1): 75, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38486268

RESUMO

BACKGROUND: Flow starvation is a type of patient-ventilator asynchrony that occurs when gas delivery does not fully meet the patients' ventilatory demand due to an insufficient airflow and/or a high inspiratory effort, and it is usually identified by visual inspection of airway pressure waveform. Clinical diagnosis is cumbersome and prone to underdiagnosis, being an opportunity for artificial intelligence. Our objective is to develop a supervised artificial intelligence algorithm for identifying airway pressure deformation during square-flow assisted ventilation and patient-triggered breaths. METHODS: Multicenter, observational study. Adult critically ill patients under mechanical ventilation > 24 h on square-flow assisted ventilation were included. As the reference, 5 intensive care experts classified airway pressure deformation severity. Convolutional neural network and recurrent neural network models were trained and evaluated using accuracy, precision, recall and F1 score. In a subgroup of patients with esophageal pressure measurement (ΔPes), we analyzed the association between the intensity of the inspiratory effort and the airway pressure deformation. RESULTS: 6428 breaths from 28 patients were analyzed, 42% were classified as having normal-mild, 23% moderate, and 34% severe airway pressure deformation. The accuracy of recurrent neural network algorithm and convolutional neural network were 87.9% [87.6-88.3], and 86.8% [86.6-87.4], respectively. Double triggering appeared in 8.8% of breaths, always in the presence of severe airway pressure deformation. The subgroup analysis demonstrated that 74.4% of breaths classified as severe airway pressure deformation had a ΔPes > 10 cmH2O and 37.2% a ΔPes > 15 cmH2O. CONCLUSIONS: Recurrent neural network model appears excellent to identify airway pressure deformation due to flow starvation. It could be used as a real-time, 24-h bedside monitoring tool to minimize unrecognized periods of inappropriate patient-ventilator interaction.


Assuntos
Aprendizado Profundo , Respiração Artificial , Adulto , Humanos , Inteligência Artificial , Pulmão , Respiração Artificial/métodos , Ventiladores Mecânicos
16.
Anaesth Crit Care Pain Med ; 43(3): 101363, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38432476

RESUMO

BACKGROUND: Ventilator-associated events (VAE) is a tier implemented for surveillance by the CDC in the USA. Implementation usefulness for clinical decisions is unknown. METHODS: We conducted a secondary analysis from a prospective, multicentre, international study, to assess the impact on outcomes of using tiers with shorter follow-up (VAE24), lower oxygenation requirements (light-VAE) or both (light VAE24). RESULTS: A cohort of 261 adults with 2706 ventilator-days were included. The median (IQR) duration of mechanical ventilation (MV) was 9 days (5-21), and the median (IQR) length of stay in the intensive care unit (ICU) was 14 days (8-26). A VAE tier was associated with a trend to increase from 32% to 44% in the ICU mortality rates. VAE Incidence was 24 per 1,000 ventilator-days, being increased when reduced the oxygenation settings requirement (35 per 1,000 ventilator-days), follow-up (41 per 1,000 ventilator-days) or both (55 per 1,000 ventilator-days). A VAE tier was associated with 13 extra (21 vs. 8) days of ventilation, 11 (23 vs. 12) ICU days and 7 (31 vs. 14) hospitalization days, outperforming the modified tiers' performance. CONCLUSIONS: The modification of ventilator settings (consistent with ventilator-associated events) was associated with worse outcomes among adults with prolonged mechanical ventilation. Monitoring ventilator-associated events at the bedside represents a new tool for quality improvement.


Assuntos
Unidades de Terapia Intensiva , Tempo de Internação , Respiração Artificial , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Adulto , Tempo de Internação/estatística & dados numéricos , Monitorização Fisiológica/métodos , Ventiladores Mecânicos/efeitos adversos , Mortalidade Hospitalar , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Pneumonia Associada à Ventilação Mecânica/prevenção & controle , Pneumonia Associada à Ventilação Mecânica/etiologia , Resultado do Tratamento , Estudos de Coortes , Incidência
17.
Respir Care ; 69(4): 449-462, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538014

RESUMO

BACKGROUND: In recent years, mechanical power (MP) has emerged as an important concept that can significantly impact outcomes from mechanical ventilation. Several individual components of ventilatory support such as tidal volume (VT), breathing frequency, and PEEP have been shown to contribute to the extent of MP delivered from a mechanical ventilator to patients in respiratory distress/failure. The aim of this study was to identify which common individual setting of mechanical ventilation is more efficient in maintaining safe and protective levels of MP using different modes of ventilation in simulated subjects with ARDS. METHODS: We used an interactive mathematical model of ventilator output during volume control ventilation (VCV) with either constant inspiratory flow (VCV-CF) or descending ramp inspiratory flow, as well as pressure control ventilation (PCV). MP values were determined for simulated subjects with mild, moderate, and severe ARDS; and whenever MP > 17 J/min, VT, breathing frequency, or PEEP was manipulated independently to bring back MP to ≤ 17 J/min. Finally, the optimum VT-breathing frequency combinations for MP = 17 J/min were determined with all 3 modes of ventilation. RESULTS: VCV-CF always resulted in the lowest MPs while PCV resulted in highest MPs. Reductions in VT were the most efficient for maintaining safer and protective MP. At targeted MPs of 17 J/min and maximized minute ventilation, the optimum VT-breathing frequency combinations were 250-350 mL for VT and 32-35 breaths/min for breathing frequency in mild ARDS, 200-350 mL for VT and 34-40 breaths/min for breathing frequency in moderate ARDS, and 200-300 mL for VT and 37-45 breaths/min for breathing frequency for severe ARDS. CONCLUSIONS: VCV-CF resulted in the lowest MP. VT was the most efficient for maintaining safe and protective MP in a mathematical simulation of subjects with ARDS. In the context of maintaining low and safe MPs, ventilatory strategies with lower-than-normal VT and higher-than-normal breathing frequency will need to be implemented in patients with ARDS.


Assuntos
Respiração Artificial , Síndrome do Desconforto Respiratório , Humanos , Respiração Artificial/métodos , Ventiladores Mecânicos , Pulmão , Volume de Ventilação Pulmonar , Síndrome do Desconforto Respiratório/terapia
18.
Pediatr Pulmonol ; 59(5): 1380-1387, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38426806

RESUMO

BACKGROUND/OBJECTIVE: Infants who survive prematurity and other critical illnesses and require continued invasive mechanical ventilation (IMV) postdischarge (at home) are at high risk of developmental delays and disabilities. Studies of extremely preterm cohorts (<28-week gestation) demonstrate rates of 25% for intellectual disability (ID) and 7% for autism spectrum disorder (ASD). Rates of ASD and ID in children with IMV are unknown. This study aimed to determine neurodevelopmental disability risk in a cohort of children with postdischarge IMV. DESIGN/METHODS: A consecutive series of children with IMV were assessed 1 month, 6 months, and 1 year after discharge. Cognitive, social, and communicative domains were assessed by a Developmental and Behavioral Pediatrician using (1) clinical adaptive test/clinical linguistic and auditory milestone scale (CAT/CLAMS) of the capute scales; (2) pediatric evaluation of disability inventory computer adaptive test (PEDI-CAT); and (3) modified checklist for autism in toddlers, revised (MCHAT-R). Red flag signs and symptoms of ASD using DSM-V criteria were noted. Longitudinal testing was reviewed. Expert consensus impressions of evolving ASD and/or ID were determined. RESULTS: Eighteen children were followed for 1 year; at 1 year, the median age (range) was 23 (17-42) months. Children were 44% male, 33% non-Hispanic White, 39% non-Hispanic Black, and 28% Hispanic. Fifteen (83%) children were prematurity survivors. Median (range) developmental quotients (DQs): full-scale DQ 59 (11-86), CAT DQ 66.5 (8-96), and CLAMS DQ 49.5 (13-100). Twelve (67%) children were highly suspicious for ASD and/or evolving ID. CONCLUSIONS/SIGNIFICANCE: This cohort of children with at-home IMV demonstrates a higher risk of ASD and ID than prior premature cohorts. Larger investigations with longer follow-up are needed.


Assuntos
Traqueostomia , Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Recém-Nascido , Respiração Artificial/estatística & dados numéricos , Transtorno do Espectro Autista , Ventiladores Mecânicos , Deficiência Intelectual , Transtornos do Neurodesenvolvimento/etiologia , Transtornos do Neurodesenvolvimento/epidemiologia , Deficiências do Desenvolvimento/etiologia , Recém-Nascido Prematuro
20.
Respir Res ; 25(1): 142, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528524

RESUMO

BACKGROUND: The underlying pathophysiological pathways how reverse triggering is being caused are not fully understood. Respiratory entrainment may be one of these mechanisms, but both terms are used interchangeably. We sought to characterize reverse triggering and the relationship with respiratory entrainment among mechanically ventilated children with and without acute lung injury. METHODS: We performed a secondary phyiology analysis of two previously published data sets of invasively mechanically ventilated children < 18 years with and without lung injury mechanically ventilated in a continuous or intermittent mandatory ventilation mode. Ventilator waveforms, electrical activity of the diaphragm measured with surface electromyography and oesophageal tracings were analyzed for entrained and non-entrained reverse triggered breaths. RESULTS: In total 102 measurements (3110 min) from 67 patients (median age 4.9 [1.8 ; 19,1] months) were analyzed. Entrained RT was identified in 12 (12%) and non-entrained RT in 39 (38%) recordings. Breathing variability for entrained RT breaths was lower compared to non-entrained RT breaths. We did not observe breath stacking during entrained RT. Double triggering often occurred during non-entrained RT and led to an increased tidal volume. Patients with respiratory entrainment related RT had a shorter duration of MV and length of PICU stay. CONCLUSIONS: Reverse triggering is not one entity but a clinical spectrum with different mechanisms and consequences. TRIAL REGISTRATION: Not applicable.


Assuntos
Lesão Pulmonar Aguda , Respiração Artificial , Criança , Humanos , Pré-Escolar , Respiração Artificial/efeitos adversos , Estudos Prospectivos , Respiração , Ventiladores Mecânicos