Migración de un dispositivo intrauterino a vejiga con litiasis vesical secundaria y cistitis recurrente como forma clínica de presentación. Reporte de caso / Migration of an intrauterine device to the bladder with secondary bladder lithiasis and recurrent cystitis as a clinical presentation. Case report
Marín Valle, Katia; Castillo-Quintana, María del Pilar; Peña Frías, Luis Miguel; González Martínez, Miguel Alejandro; Hernández Francisco, Alberto Alian.
Affiliation
  • Marín Valle, Katia; Hospital General Provincial Camilo Cienfuegos. Sancti Spíritus. CU
  • Castillo-Quintana, María del Pilar; Hospital General Provincial Camilo Cienfuegos. Sancti Spíritus. CU
  • Peña Frías, Luis Miguel; Universidad de Ciencias Médicas. Sancti Spíritus. CU
  • González Martínez, Miguel Alejandro; Universidad de Ciencias Médicas. Sancti Spíritus. CU
  • Hernández Francisco, Alberto Alian; Universidad de Ciencias Médicas. Sancti Spíritus. CU
Gac. méd. espirit ; 23(2): 107-114, 2021. graf
Article in Spanish | LILACS | ID: biblio-1339939
Responsible library: CU420.1
RESUMEN
RESUMEN Fundamento El dispositivo intrauterino ha sido utilizado durante muchos años como método anticonceptivo; una complicación infrecuente posterior a su inserción es la migración fuera del útero. La localización vesical y la formación de vesicolitiasis, son complicaciones asociadas a la migración.

Objetivo:

Presentar un caso de migración de un dispositivo intrauterino a vejiga con litiasis sobreañadida como inusual etiología de una cistitis recurrente. Presentación del caso Caso clínico de un dispositivo intrauterino en vejiga en una paciente de 43 años, cuyo diagnóstico se realizó incidentalmente en estudio de cistitis recurrente; se diagnosticó imagenológica y endoscópicamente en consulta de Urología; se decidió tratamiento quirúrgico mediante cistolitotomía a cielo abierto y se extrajo un cálculo de 4x5 cm de diámetro. La paciente evolucionó satisfactoriamente.

Conclusiones:

Considérese la posibilidad de migración del dispositivo intrauterino a la vejiga con litiasis sobreañadida como causa de cistitis recurrente, en pacientes femeninas que tengan antecedente de uso de este método anticonceptivo, lo que constituye un elemento importante en el diagnóstico y tratamiento de la infección urinaria baja.
ABSTRACT
ABSTRACT

Background:

The intrauterine device has been used for years as a contraceptive method; a non-frequent complication after its insertion is migration out of the uterus. The bladder location and the formation of vesicolithiasis are complications associated with migration.

Objective:

To present a migration case from an intrauterine device to the bladder with overadded lithiasis as an unusual etiology of recurrent cystitis. Case report Clinical case of an intrauterine device in the bladder in a 43-year-old patient, whose diagnosis was made incidentally in a recurrent cystitis study, it was diagnosed by imaging and endoscopy in the Urology consultation; surgical treatment was decided by means of open cystolithotomy and a stone 4x5 cm in diameter was extracted. The patient evolved satisfactorily.

Conclusions:

To consider the possibility of migration of the intrauterine device to the bladder with overadded lithiasis as a cause of recurrent cystitis in female patients who have a preceding use of this contraceptive method, thus it constitutes an important element in the diagnosis and treatment of urinary lower infection.
Subject(s)

Full text: Available Collection: International databases Database: LILACS Main subject: Uterine Perforation / Urinary Bladder Calculi / Cystitis / Intrauterine Device Migration / Intrauterine Devices Language: Spanish Journal: Gac. méd. espirit Journal subject: Medicine Year: 2021 Document type: Article Affiliation country: Cuba Institution/Affiliation country: Hospital General Provincial Camilo Cienfuegos/CU / Universidad de Ciencias Médicas/CU
Full text: Available Collection: International databases Database: LILACS Main subject: Uterine Perforation / Urinary Bladder Calculi / Cystitis / Intrauterine Device Migration / Intrauterine Devices Language: Spanish Journal: Gac. méd. espirit Journal subject: Medicine Year: 2021 Document type: Article Affiliation country: Cuba Institution/Affiliation country: Hospital General Provincial Camilo Cienfuegos/CU / Universidad de Ciencias Médicas/CU
...