Your browser doesn't support javascript.
loading
Fórmula Barrett True K en pacientes con catarata operados de cirugía refractiva corneal / The Barrett True-K formula in cataract patients undergoing corneal refractive surgery
Pérez Candelaria, Eneida de la C; Cangrejo Forero, Edgar Iván; Veitía Rovirosa, Zucell Ana; Álvarez Pérez, Melany; Cárdenas Díaz, Taimi.
Affiliation
  • Pérez Candelaria, Eneida de la C; Instituto Cubano de Oftalmología Ramón Pando Ferrer. CU
  • Cangrejo Forero, Edgar Iván; Instituto Cubano de Oftalmología Ramón Pando Ferrer. CU
  • Veitía Rovirosa, Zucell Ana; Instituto Cubano de Oftalmología Ramón Pando Ferrer. CU
  • Álvarez Pérez, Melany; Instituto Cubano de Oftalmología Ramón Pando Ferrer. CU
  • Cárdenas Díaz, Taimi; Instituto Cubano de Oftalmología Ramón Pando Ferrer. CU
Rev. cuba. oftalmol ; 34(2): e1046, 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1341451
Responsible library: CU1.1
RESUMEN

Objetivo:

Determinar los resultados refractivos en pacientes operados de catarata con cirugía refractiva corneal, según el cálculo del poder dióptrico de la lente intraocular con la fórmula Barrett True K.

Métodos:

Se realizó un estudio pre-experimental, del tipo antes y después, en el cual fueron incluidos 18 pacientes (31 ojos). En ellos se analizaron variables demográficas y clínicas. La principal variable de salida fue la predictibilidad del componente esférico ± 0,50 D, ± 1,0 D según la longitud axial.

Resultados:

Fueron estudiados pacientes con un promedio de edad de 59,4 años, predominantemente del sexo femenino (66,7 por ciento). El 77,4 por ciento fue operado con queratotomía radial. Con la cirugía de catarata se produjo una mejora ostensible de la agudeza visual no corregida (mediana preoperatoria 0,12 y mediana posoperatoria 0,60). Solo el 9,7 por ciento de los ojos analizados presentó una agudeza visual sin corregir de 20/20 y el 90,3 por ciento de 20/40 o más. La cantidad de ojos con un equivalente esférico de ± 0,50 disminuyó en la medida en que aumentó la longitud axial (corta 100 por ciento; normal 57,1 por ciento; larga 22,7 por ciento), no así la predictibilidad del componente esférico de ± 0,50, que aumentó (corta 50,0 por ciento; normal 57,1 por ciento; larga 63,6 por ciento).

Conclusiones:

La fórmula Barrett True K resulta útil para el cálculo de la lente intraocular en pacientes operados de catarata y cirugía refractiva corneal previa(AU)
ABSTRACT

Objective:

Determine refractive outcomes in patients undergoing cataract corneal refractive surgery based on intraocular lens dioptric power calculation with the Barrett True-K formula.

Methods:

A pre-experimental before/after study was conducted of 18 patients (31 eyes). Demographic and clinical variables were analyzed. The main output variable was spherical component predictability ± 0.50 D, ± 1.0 D according to axial length.

Results:

Mean age was 59.4 years; female sex prevailed (66.7 percent). Of the patients studied, 77.4 percent underwent radial keratotomy. Cataract surgery led to notable uncorrected visual acuity improvement (preoperative mean 0.12; postoperative mean 0.60). Only 9.7 percent of the eyes examined had an uncorrected visual acuity of 20/20, whereas 90.3 percent had 20/40 or more. The number of eyes with a spherical equivalent of ± 0.50 fell as axial length rose (near 100 percent; normal 57.1 percent; far 22.7 percent), unlike ± 0.50 spherical component predictability, which rose from near 50.0 percent; normal 57.1 percent; far 63.6 percent.

Conclusions:

The Barrett True-K formula is useful for intraocular lens calculation in patients undergoing previous cataract and corneal refractive surgery(AU)
Subject(s)

Full text: Available Collection: International databases Database: CUMED / LILACS Main subject: Lens Implantation, Intraocular / Refractive Surgical Procedures Type of study: Prognostic study Limits: Female / Humans Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2021 Document type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU
Full text: Available Collection: International databases Database: CUMED / LILACS Main subject: Lens Implantation, Intraocular / Refractive Surgical Procedures Type of study: Prognostic study Limits: Female / Humans Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2021 Document type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU
...