Your browser doesn't support javascript.
loading
Techniques and Outcomes of the No-Touch Vein Conduit as a Y-Composite Graft
Kim, Ki-Bong; Hwang, Seong Wook; Kim, Min-Seok.
Affiliation
  • Kim, Ki-Bong; Myongji Hospital. Cardiovascular Center. Goyang-si. KR
  • Hwang, Seong Wook; Myongji Hospital. Cardiovascular Center. Goyang-si. KR
  • Kim, Min-Seok; Myongji Hospital. Cardiovascular Center. Goyang-si. KR
Rev. bras. cir. cardiovasc ; 37(spe1): 38-41, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1407342
Responsible library: BR1.1
ABSTRACT
ABSTRACT Although the saphenous vein is a widely used conduit for coronary artery bypass grafting, revascularization using the saphenous vein as an aortocoronary bypass graft has shown disadvantages of lower long-term graft patency rates and subsequently worse clinical outcomes, compared with revascularization using the internal thoracic artery. Of the various efforts to overcome the limitations of vein conduit that are resulting from structural and functional differences from arterial conduit, recent technical improvement in no-touch vein composite graft construction and outcomes of revascularization using no-touch vein composite grafts based on the left internal thoracic artery will be discussed in this topic.


Full text: Available Collection: International databases Database: LILACS Language: English Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / CIRURGIA GERAL Year: 2022 Document type: Article Affiliation country: South Korea Institution/Affiliation country: Myongji Hospital/KR

Full text: Available Collection: International databases Database: LILACS Language: English Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / CIRURGIA GERAL Year: 2022 Document type: Article Affiliation country: South Korea Institution/Affiliation country: Myongji Hospital/KR
...