Osteossíntese de tibiotarso através de configuração tieinem Gavião Asa-De-Telha (Parabuteo unicinctus) - Relato de Caso / Tibiotarsus osteosynthesis in Harris's hawk using tie-in a case report
Ciênc. Anim. (Impr.)
; 27(2): 50-54, 2017. ilus
Article
in Pt
| VETINDEX
| ID: biblio-1472323
Responsible library:
BR68.1
Localization: BR68.1
ABSTRACT
The method of fixation should be well tolerated and its application must be made in theshortest possible surgery and anesthesia times. This report describes the surgicalmanagement of a Harris's hawk who, on orthopedic examination, had functional impotenceof the pelvic limb right. A transverse complete fracture of the tibiotarsus was observed onradiographic examination. Closed fracture reduction was chosen and osteosynthesis withhybrid external fixator with tied-in intramedullary pin. After 30 days it was bone healingwas confirmed.