Efeito da conexão protética, da altura óssea e do material restaurador da coroa, na distribuição das microdeformações em implantes unitários / Effect of prosthetic connection, bone height, and restorative material in the distribution of stress in posterior unitary implant
São Josè dos campos; s.n; 2023. 112 p. ilus, tab.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1512827
Responsible library: BR243.1
Localization: BR243.1
RESUMO

Objetivo:

O presente estudo avaliou, por meio da extensometria, as microdeformações geradas ao redor de implantes, em duas conexões protéticas hexágono externo(HE) e cone morse(CM), em duas diferentes níveis ósseos sem perda e com perda de 5 milímetros, em coroas unitárias implantossuportada, confeccionadas em diferentes materiais restauradores resina acrílica, totalmente metálica, metalocerâmica e cerâmica pura. Material e

Métodos:

Sete blocos retangulares de 95 x 45 x 30 mm foram utilizados para simular o tecido ósseo, possuindo um degrau de 5 mm, que simulou uma perda óssea. Foram utilizados 28 implantes (3,75 x 13 mm) de mesmo desenho externo, mas diferentes plataformas protéticas, o pilar protético selecionado para o HE foi o UCLA e para o CM o CMN. O ensaio mecânico foi realizado por meio de um dispositivo de aplicação de carga (DAC) com carregamentos estáticos axiais sobre a superfície oclusal das coroas, com carga de 31,5 kgf por 10 segundos, sob três repetições. Os dados foram avaliados por teste ANOVA e Tukey com nível de significância 5% (P - 0,05).

Resultados:

Os resultados obtidos pela extensômetros demonstraram que em relação ao nível ósseo e a conexão protética, houve diferença estatística entre os grupos de implantes à nível ósseo (HE - 308,6793 µÎµ e CM - 457,0536 µÎµ), contudo com a simulação de perda óssea de 5mm não registraram diferença estatística ( HE - 563,0707 µÎµ e CM - 522,8788 ). Em relação ao material da coroa, não houve diferença estatística independente da conexão protética e do nível ósseo ( Co-cr 528,99µÎµ, metalocerâmica420,57µÎµ, resina 435,33µÎµ e cerâmica pura 462,92µÎµ).

Conclusão:

O estudo concluiu que os implantes à nível ósseo com a conexão protética HE registrou valores de microdeformações estatisticamente menores que o CM, mas com 5 mm de perda o comportamento foi semelhante. Os diferentes materiais das coroas avaliados, não foram capazes de reduzir os valores de microdeformação, independente do nível ósseo do implante. (AU)
ABSTRACT

Objective:

The present study evaluated, by means of extensometry, the microdeformations generated around implants, in different systems External Hexagon (EH) and Cone Morse (CM), in two different bone heights No bone loss and 5mm bone loss, in unitary crown implant, of different restorative materials (acrylic resin, metallic, metal-ceramic or all-ceramic). Material and

Methods:

Seven rectangular block with dimensions of 95 x 45 x 30 mm was used to simulate bone tissue, containing a 5 mm step, which simulated bone loss. 28 implants (3.75 x 13 mm) with the same geometry and different prosthetic platforms were used, the abutment of choice for the EH was the UCLA and for the CM the CMN. The mechanical test was performed using a load application device (DAC) with axial static loads on the occlusal surface of the crowns, the load used was 31.5 kgf for 10 seconds, with three repetitions. Data were evaluated by ANOVA and Tukey tests with significance level 5% (P - 0.05).

Results:

The results obtained by the strain gauges showed that in relation to the bone level and the prosthetic connection, there was a statistical difference between the groups of implants at the bone level (EH - 308.6793 µÎµ and CM - 457.0536 µÎµ), however, with the simulation of 5mm bone loss, there was no statistical difference (EH - 563.0707 µÎµ and CM - 522.8788). Regarding crown material, there was no statistical difference regardless of the prosthetic connection and bone level. (Co-Cr 528.99µ).

Conclusion:

The study concluded that bone-level implants with the HE prosthetic connection registered statistically lower microdeformation values than the CM, but with 5 mm of loss the behavior was similar. The different crown materials evaluated were not able to reduce the microdeformation values, regardless of the bone level of the implant. (AU)