Desfechos Intra-Hospitalares no Registro Brasileiro de Implante de Bioprótese Aórtica por Cateter - 14 Anos em Análise / In-Hospital Outcomes in the Brazilian Registry of Transcatheter Aortic Valve Implantation - 14-Year Analysis
Arq. bras. cardiol
; Arq. bras. cardiol;121(5): e20230551, 2024. tab, graf
Article
in Pt
|
LILACS-Express
| LILACS
| ID: biblio-1573927
Responsible library:
BR1.1
RESUMO
Resumo Fundamento O implante valvar aórtico transcateter (TAVI) apresenta crescimento exponencial de suas indicações e foi incorporado ao Sistema Único de Saúde em 2022, sendo necessário avaliar seu uso no Brasil. Objetivo Conhecer os fatores associados a mortalidade e complicações não fatais intra-hospitalares, em ambos os gêneros, na população do Registro Brasileiro de Implante de Bioprótese Aórtica por Cateter e Novas Tecnologias (RIBAC-NT). Método Análise do banco de dados RIBAC-NT de 2008 a 2022. Aplicados modelos logísticos e machine learning na avaliação estatística da associação das variáveis com os desfechos, empregando o software R e nível de significância de 5%. Resultados Analisados 2.588 pacientes (mulheres, 51,2%; óbito intra-hospitalar, 8,2%). Mortalidade associou-se a complicações do procedimento, dentre elas destacam-se complicações vasculares (CV) maiores e insuficiência renal aguda (IRA) (p< 0,001). A CV maior ocorreu em 6%, com 34% de mortalidade; IRA ocorreu em 8,8%, com 13% de mortalidade, que aumentou até 8 vezes quando IRA coexistiu com outras complicações. Complicações não fatais ocorreram em 50,5% do total de pacientes, acometendo 63% daqueles com bioprótese de 1a geração (1G) e 39% daqueles com bioprótese de 2a geração (2G) p<0,001. O acesso não femoral e o ritmo cardíaco influenciaram as complicações não fatais nas próteses 1G, enquanto complicações das próteses 2G associaram-se ao gênero feminino (39,6% vs. 30,4%, p= 0,003). Conclusão A mortalidade intra-hospitalar na população do RIBAC-NT associou-se diretamente a complicações do procedimento, principalmente CV maior e IRA. A ocorrência de complicações não fatais diferiu conforme o gênero e o tipo da bioprótese.
ABSTRACT
Abstract Background Transcatheter aortic valve implantation (TAVI) has had an exponential increase of its indication, being incorporated into the Brazilian Unified Public Health System in 2022, thus requiring assessment of its use in Brazil. Objeticve To assess the factors associated with in-hospital mortality and non-fatal complications in both genders in the Brazilian Registry of Transcatheter Aortic Valve Implantation and New Technologies (RIBAC-NT) population. Method Analysis of the RIBAC-NT database from 2008 to 2022 was performed. Logistic models and machine learning were used for statistical assessment of the association between variables and outcomes. The software R was used and a 5% significance level, adopted. Results Analysis of 2588 patients (women, 51.2%; in-hospital death, 8.2%). Mortality was associated with procedural complications, of which major vascular complication (VC) and acute kidney injury (AKI) stood out (p<0.001). Major VC occurred in 6% of the patients, with 34% mortality; AKI occurred in 8.8%, with 13% mortality, which increased up to 8 times when AKI coexisted with other complications. Non-fatal complications occurred in 50.5% of all patients, affecting 63% of those with 1st generation (1G) bioprosthesis and 39% of those with 2nd generation (2G) bioprosthesis (p<0,001). Non-femoral access and heart rhythm influenced non-fatal complications in patients with 1G prostheses, while complications in patients with 2G prosthesis associated with the female gender (39.6% vs. 30.4%, p=0.003). Conclusion In-hospital mortality in the RIBAC-NT population was directly associated with procedural complications, mainly major VC and AKI. The occurrence of non-fatal complications differed according to gender and bioprosthesis type.
Aortic Valve Disease; Aortic Valve Stenosis; Estenose da Valva Aórtica; Heart Valve Prosthesis Implantation; Heart Valve Prosthesis; Implante de Prótese de Valva Cardíaca; Próteses Valvulares Cardíacas; Substituição da Valva Aórtica Transcateter; Transcatheter Aortic Valve Replacement; Valvopatia Aórtica
Full text:
1
Collection:
01-internacional
Database:
LILACS
Country/Region as subject:
America do sul
/
Brasil
Language:
Pt
Journal:
Arq. bras. cardiol
Journal subject:
CARDIOLOGIA
Year:
2024
Document type:
Article
Affiliation country:
Brazil
Country of publication:
Brazil