Your browser doesn't support javascript.
loading
Erosión muy tardía de la aurícula derecha con dispositivo Amplatzer®; reporte de un caso / Very late erosion of the right atrium with Amplatzer® device
Zuñiga Luna, Mauricio; Gallego Muñoz, Catalina; Vásquez Villegas, Sara; Rendón Isaza, Juan Camilo; Uribe, Carlos Esteban.
Affiliation
  • Zuñiga Luna, Mauricio; Universidad Pontificia Bolivariana. Medellín. CO
  • Gallego Muñoz, Catalina; Universidad Pontificia Bolivariana. Medellín. CO
  • Vásquez Villegas, Sara; Universidad Pontificia Bolivariana. Medellín. CO
  • Rendón Isaza, Juan Camilo; Universidad Pontificia Bolivariana. Medellín. CO
  • Uribe, Carlos Esteban; Universidad Pontificia Bolivariana. Medellín. CO
Arch. cardiol. Méx ; 86(3): 271-275, jul.-sep. 2016. graf
Article in Spanish | LILACS | ID: biblio-838384
Responsible library: BR1.1
RESUMEN
Resumen La erosión tardía de la pared auricular y de la aorta es una causa infrecuente, pero potencialmente mortal en los pacientes que han sido sometidos al cierre percutáneo de un defecto del septum auricular, en especial cuando existe una alta relación entre el tamaño del dispositivo escogido con el tamaño del defecto y la presencia de bordes insuficientes. Presentamos el caso de un hombre de 70 años con un episodio de colapso hemodinámico secundario a taponamiento cardiaco debido a erosión muy tardía de la aurícula derecha por un Amplatzer® implantado 4 años atrás para el cierre de un defecto septal auricular. Conclusión La erosión tardía de los dispositivos de cierre percutáneo para los defectos atriales, aunque infrecuente, deberá ser tenida en cuenta en los pacientes que presentan colapso hemodinámico.
ABSTRACT
Abstract Late atrial wall and aorta erosion is a rare cause of potential fatallity in patients who have undergone percutaneous closure of an atrial septal defect, especially when a high ratio device to defect is chosen, and an insufficient aortic rim is present. We report the case of a 70 year old male with an episode of hemodinamic collapse secondary to cardiac tamponade due to a late erosion of a 4 years ago implanted Amplatzer® used to close an atrial septal defect. Conclusion Very late wall erosion of an atrial septal closure device, although uncommon, should be suspected in patients presenting with hemodynamic collapse.
Subject(s)


Full text: Available Collection: International databases Database: LILACS Main subject: Postoperative Complications / Septal Occluder Device / Heart Atria / Heart Septal Defects, Atrial Limits: Aged / Humans / Male Language: Spanish Journal: Arch. cardiol. Méx Journal subject: Cardiology Year: 2016 Document type: Article Affiliation country: Colombia Institution/Affiliation country: Universidad Pontificia Bolivariana/CO

Full text: Available Collection: International databases Database: LILACS Main subject: Postoperative Complications / Septal Occluder Device / Heart Atria / Heart Septal Defects, Atrial Limits: Aged / Humans / Male Language: Spanish Journal: Arch. cardiol. Méx Journal subject: Cardiology Year: 2016 Document type: Article Affiliation country: Colombia Institution/Affiliation country: Universidad Pontificia Bolivariana/CO
...