RESUMO
A busca pelo correto assentamento entre as estruturas metálicas e os intermediários protéticos das próteses implantossuportadas tornou-se um desafio entre os clínicos que trabalham com a osseointegração. Este objetivo se constitui em um importante fator de sucesso no tratamento, pois proporciona uma passividade entre os componentes do sistema prótese, implante e tecidos peri-implantares. No entanto, deve-se considerar que atingir esta meta é extremamente difícil, devido às possíveis distorções sofridas no trabalho, através das várias fases clínicas e laboratoriais. Este estudo visou, através de um ensaio laboratorial, avaliar as imperfeições sofridas, a partir da fase de ciclagem de cocção da porcelana, em seis estruturas de arco total em Ni-Cr. As mesmas foram divididas em 3 em monobloco e 3 com 4 soldas. Foram avaliadas a distorção vertical na interface cilindro protético/intermediário e na distorção horizontal. Nesse sentido procurou-se direcionar a observação das distorções ocorridas através de 3 pontos de referência. Acrescenta-se a esta situação a instalação de uma barra estabilizadora, para se verificar a influência da mesma no procedimento de ciclagem de cocção. A leitura se procedeu em microscópio óptico e os dados foram trabalhados através de uma metodologia estatística com nível de significância de p<0,05. A análise de variância (ANOVA) mostrou diferenças estatisticamente significantes nas medidas no sentido vertical nas fases antes e depois. No grupo de estruturas com 4 soldas, houve diferença estatisticamente significante nas fases antes, depois, barra antes e barra depois e após o corte. O resultado deste estudo confirmou que existe uma distorção no sentido vertical antes e depois do ciclo de cocção da porcelana e a barra transversal conteve as tensões das estruturas submetidas aos ciclos de cocção, principalmente no sentido horizontal, aumentando após o corte da mesma.
ABSTRACT
It still a great challenge for the clinicians that works on the osseointegration field, to pursue the best fitting between the metal framework and the prothetics components of a implant supported. This goal became an important factor of a long term success in the treatment, because the integrity of the system, perimplant tissues and prosthesis depend on the passivity of the prosthetics components. However, so as to reach the best results, it should be aware of the distortion that might occur during the clinical and laboratory phases. This study aimed to evaluate the distortion that occurred at the framework after the porcelain firing thermal cycle. It were used 6 based alloy Ni-Cr full arch frameworks divided in two groups 3 one-piece and 3 with four solder joints. They were analysed in terms of vertical and horizontal discrepancies. It was also used as stabilizing bar soldered in the framework to compare its influence factor on the distortion of the frameworks after the porcelain firing thermal cycle. It was used an optical microscope to read the discrepancies of the frameworks. The data were submitted to a statistical analysis by variance analysis (ANOVA) p<0.05. This test showed statistical difference in the vertical measurements before and after thermal cycles. In the group of four solder joints was found statistical difference among groups before, after, bar before, bar after and after cutting. This study confirms the vertical distortion that occurs in the prosthetic framework after the porcelain firing thermal cycle. The transversal bar connected at the framework is capable to support the distortion that occurred before and after the porcelain firing thermal cycle, however when the bar was cut it showed a discrepancy on the horizontal plane.
Subject(s)

Search on Google
Collection: National databases Database: BBO - Dentistry Main subject: Materials Testing / Dental Marginal Adaptation / Dental Prosthesis, Implant-Supported / Dental Porcelain Language: Portuguese Journal: Rev. dental press periodontia implantol Year: 2007 Document type: Article Institution/Affiliation country: Universidade do Sagrado Coração/BR
Search on Google
Collection: National databases Database: BBO - Dentistry Main subject: Materials Testing / Dental Marginal Adaptation / Dental Prosthesis, Implant-Supported / Dental Porcelain Language: Portuguese Journal: Rev. dental press periodontia implantol Year: 2007 Document type: Article Institution/Affiliation country: Universidade do Sagrado Coração/BR
...