Your browser doesn't support javascript.
loading
Avaliação comparativa da precisão de adaptação de dois tipos de infra-estruturas para prótese protocolo antes e após aplicação de carga cíclica / Comparative evaluation of the accuracy of adapting two types of infrastructures for prosthetic protocol before and after application of cyclic loading
Campinas; s.n; 2008. 101 p. ilus.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-866516
Responsible library: BR1354.1
Localization: BR1354.1; D D762, 5616
RESUMO
Desde as primeiras próteses protocolo realizadas por Branemark et al. a passividade das infra-estruturas metálicas, tem merecido especial atenção de clínicos e pesquisadores. O objetivo deste estudo foi realizar uma análise comparativa da precisão de adaptação entre duas infra-estruturas metálicas de uma prótese total mandibular implanto suportada, a fim de observar a alteração da passividade de assentamento antes e após a aplicação de cargas de flexão, sendo uma soldada a laser e outra fundida. Para que este estudo fosse realizado foram confeccionadas duas barras, uma utilizando-se cilindros de titânio para mini-pilares cônicos unidos por solda a laser a uma barra de secção circular também de titânio e outra, utilizando-se uma barra fundida, também de secção circular, em cromo-cobalto e então aderida com cimento resinoso em cilindros de titânio para mini-pilares cônicos. As barras foram confeccionadas em modelos de resina acrílica, de alta resistência mecânica, que foram obtidos a partir da duplicação do modelo de um caso real, onde as angulações dos implantes não são exatamente paralelas. Utilizaram-se análogos de mini-pilares cônicos, confeccionados em titânio em ambas as infra-estruturas. Os modelos foram então levados a uma máquina de ensaios universal, EMIC 2000, para aplicação das cargas cíclicas compressivas na região do cantilever, esta região foi escolhida por ser biomecanicamente a mais requisitada neste tipo de estrutura. Após as barras serem fixadas ao modelo, com um torque de 10 N/cm, foram aplicadas cargas cíclicas simulando a mastigação, 54 ciclos a uma força constante de 12 Kgf, alternando-se lados direito e esquerdo com o reaperto dos parafusos entre as aplicações da carga num primeiro momento e sem o reaperto num segundo momento. Após a coleta dos dados e execução dos cálculos estatísticos foi realizada a comparação das desadaptações ocorridas em cada uma das barras e a observação de seu estado após a aplicação das mesmas... .
ABSTRACT
Since the first protocol prostheses made by Branemark et al. the passivity of infrastructure metal, has received special attention of clinicians and researchers. The objective of this study carried out a comparative analysis of the precision of adaptation between the components of the system and observed the alteration of the passivity after the application of loads of flexing in two types of infrastructures for total inferior prosthesis on implants. So that this study was taken to term, two bars were made, one when cylinders of titanium are used for conical mini-pillars joined by solder to laser circulating a bar of section also of titanium, and other one, when a fused bar is used, also of circular section, in Chrome-cobalt and then cemented with resinous cement for attachments in cylinders of titanium for conical mini-pillars (microunit). The bars were made in models of acrylic resin of high mechanical resistance, which were obtained from the duplication of the model of a real case, where the angulations of the implants are not exactly parallel as they were done in a model of laboratory. Was used analogous of conical mini-pillars made in titanium of in both infrastructures. The models were taken then to a machine of tests universal EMIC 2000 to check his capacity of receiving cyclical compressive loads in the region of the cantilever, this region was chosen because of being biomechanicaly the made a request one in this type of structure. Firstly cyclical loads were applied simulating to mastication (54 cycles of each side, to a constant strength of 12 Kgf tight the screws again after each cycle of compressions in the axial sense and then measuring the misfit occurred through an optical microscope). After the repressure of the screws, there were applied more 54 cycles of load of each side, to put without proceeding to the repressure of the screws, and after this, it was then fulfilled to mensuration of the desadaptações when... .
Subject(s)

Full text: Available Collection: National databases Database: BBO - Dentistry Main subject: Dental Implants / Dental Prosthesis, Implant-Supported Type of study: Practice guideline Language: Portuguese Year: 2008 Document type: Thesis
Full text: Available Collection: National databases Database: BBO - Dentistry Main subject: Dental Implants / Dental Prosthesis, Implant-Supported Type of study: Practice guideline Language: Portuguese Year: 2008 Document type: Thesis
...