Your browser doesn't support javascript.
loading
Crossense em paciente portador de marcapasso por hipersensibilidade do seio carotídeo / Far-field in patient with pacemaker due to carotid sinus hypersensitivity
Melgar, Maykyol Avaroma; Duarte, Carlos Eduardo; Galvão Filho, Silas dos Santos; De Mello, Sônia Lúcia.
Affiliation
  • Melgar, Maykyol Avaroma; Centro Avançado de de Ritmologia e Eletrofisiologia (CARE). Cardiologia. São Paulo - SP. BR
  • Duarte, Carlos Eduardo; Centro Avançado de de Ritmologia e Eletrofisiologia (CARE). Eletrofisiologia Invasiva. São Paulo - SP. BR
  • Galvão Filho, Silas dos Santos; Eletrofisiologia Invasiva. São Paulo - SP. BR
  • De Mello, Sônia Lúcia; Centro Avançado de de Ritmologia e Eletrofisiologia (CARE). Métodos Gráficos. São Paulo - SP. BR
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 30(4): f:162-l:166, out.-dez. 2017. ilus
Article in Pt | LILACS | ID: biblio-879946
Responsible library: BR44.1
Localization: BR44.1
RESUMO
Relata-se o caso de um paciente portador de marcapasso dupla-câ- mara, implantado por hipersensibilidade do seio carotídeo, que, em consulta ambulatorial, manifestou reaparecimento tardio dos sintomas que apresentava antes do implante do dispositivo. Após descartar alterações de limiares, sensibilidade ou impedância do sistema de estimulação cardíaca, foi realizada massagem do seio carotídeo e evidenciada inibição inadequada da estimulação ventricular. A radiografia de tórax revelou tratar-se de cabo-eletrodo ventricular posicionado em região látero-basal do ventrículo esquerdo via seio coronário. O problema foi corrigido com ajustes dos parâmetros, devidamente comprovado com a não reprodutibilidade do evento
ABSTRACT
We report the case of a patient with a dual-chamber pacemaker for carotid sinus hypersensitivity who, at an outpatient visit, presented a late resumption of the symptoms observed before the implantation of the device. After discarding threshold, sensitivity or impedance changes of the cardiac stimulation system, carotid sinus massage was performed and inadequate ventricular pacing inhibition was evidenced. A chest X-ray showed the ventricular lead had been placed at the laterobasal region of left ventricle through the coronary sinus. The problem was corrected by adjusting the parameters, and this was confirmed by a discontinuation of the event
Subject(s)
Collection: 01-internacional Database: LILACS Main subject: Pacemaker, Artificial / Carotid Sinus / Electrodes, Implanted / Hypersensitivity Type of study: Diagnostic_studies / Etiology_studies / Risk_factors_studies Limits: Aged / Humans / Male Language: Pt Journal: RELAMPA, Rev. Lat.-Am. Marcapasso Arritm Journal subject: CARDIOLOGIA Year: 2017 Document type: Article Affiliation country: Brazil Country of publication: Brazil
Collection: 01-internacional Database: LILACS Main subject: Pacemaker, Artificial / Carotid Sinus / Electrodes, Implanted / Hypersensitivity Type of study: Diagnostic_studies / Etiology_studies / Risk_factors_studies Limits: Aged / Humans / Male Language: Pt Journal: RELAMPA, Rev. Lat.-Am. Marcapasso Arritm Journal subject: CARDIOLOGIA Year: 2017 Document type: Article Affiliation country: Brazil Country of publication: Brazil