Ultrasonic method of microvibration detection: part II - additional processing method and applications
Costa Júnior, José Francisco Silva; Machado, João Carlos.
Affiliation
  • Costa Júnior, José Francisco Silva; Federal University of Rio de Janeiro. Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia. Biomedical Engineering Program. Rio de Janeiro. BR
  • Machado, João Carlos; Federal University of Rio de Janeiro. Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia. Biomedical Engineering Program. Rio de Janeiro. BR
Res. Biomed. Eng. (Online) ; 33(3): 218-228, Sept. 2017. tab, graf
Article in En | LILACS | ID: biblio-896186
Responsible library: BR1178.1
ABSTRACT
Abstract Introduction In the last 28 years, the scientific community has been using elastography to evaluate the mechanical properties of biological tissue. The aim of this work was the optimization of the UDmV method, presented in Part I of the series, by means of modifying the technique employed to generate the reference sine and cosine functions, used for phase-quadrature demodulation, and determining how this modification improved the performance of the method. Additionally, the UDmV was employed to characterize the acoustic and mechanical properties of a 7% gelatin phantom. Methods A focused transducer, T F, with a nominal frequency of 2.25 MHz, was used to induce the shear waves, with frequency of 97.644 Hz. Then, the modified UDmV method was used to extract the phase and quadrature components from ultrasonic RF echo-signals collected from four positions along the propagation path of the shear wave, which allowed the investigation of the medium vibration caused by wave propagation. The phase velocity, c s, and attenuation, α s, of the phantom were measured and employed in the calculation of shear modulus, μ, and viscosity, η. Results The computational simulation demonstrated that the modification in UDmV method resulted in more accurate and precise estimates of the initial phases of the reference sinusoidal functions used for phase-quadrature demodulation. The values for c s and μ of 1.31 ± 0.01 m·s-1 and 1.66 ± 0.01 kPa, respectively, are very close to the values found in the literature (1.32 m·s-1 and 1.61 kPa) for the same material. Conclusion The UDmV method allowed estimating of the acoustic and viscoelastic parameters of phantom.
Key words

Full text: 1 Collection: 01-internacional Database: LILACS Type of study: Diagnostic_studies Language: En Journal: Res. Biomed. Eng. (Online) Journal subject: Engenharia Biom‚dica Year: 2017 Document type: Article Affiliation country: Brazil Country of publication: Brazil

Full text: 1 Collection: 01-internacional Database: LILACS Type of study: Diagnostic_studies Language: En Journal: Res. Biomed. Eng. (Online) Journal subject: Engenharia Biom‚dica Year: 2017 Document type: Article Affiliation country: Brazil Country of publication: Brazil