Ultrassom à beira do leito como ferramenta prática para avaliação da massa muscular / Bedside ultrasound is a practical measurement tool for assessing muscle mass
Toledo, Diogo Oliveira; Silva, Débora Carneiro de Lima e; Santos, Dyaiane Marques dos; Freitas, Branca Jardini de; Dib, Rogério; Cordioli, Ricardo Luiz; Figueiredo, Evandro José de Almeida; Piovacari, Silvia Maria Fraga; Silva J, João Manoel.
Affiliation
  • Toledo, Diogo Oliveira; Hospital Israelita Albert Einstein. Unidade de Terapia Intensiva. São Paulo. BR
  • Silva, Débora Carneiro de Lima e; Hospital Israelita Albert Einstein. Unidade de Terapia Intensiva. São Paulo. BR
  • Santos, Dyaiane Marques dos; Hospital Israelita Albert Einstein. Unidade de Terapia Intensiva. São Paulo. BR
  • Freitas, Branca Jardini de; Hospital Israelita Albert Einstein. Unidade de Terapia Intensiva. São Paulo. BR
  • Dib, Rogério; Hospital Israelita Albert Einstein. Unidade de Terapia Intensiva. São Paulo. BR
  • Cordioli, Ricardo Luiz; Hospital Israelita Albert Einstein. Unidade de Terapia Intensiva. São Paulo. BR
  • Figueiredo, Evandro José de Almeida; Hospital Israelita Albert Einstein. Unidade de Terapia Intensiva. São Paulo. BR
  • Piovacari, Silvia Maria Fraga; Hospital Israelita Albert Einstein. Unidade de Terapia Intensiva. São Paulo. BR
  • Silva J, João Manoel; Hospital Israelita Albert Einstein. Unidade de Terapia Intensiva. São Paulo. BR
Rev. bras. ter. intensiva ; 29(4): 476-480, out.-dez. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-899543
Responsible library: BR1.1
RESUMO
RESUMO

Objetivo:

Avaliar a intra e interconfiabilidade, e a facilidade de medir a espessura muscular do quadríceps, usando ultrassom à beira do leito.

Métodos:

Trata-se de um estudo prospectivo, observacional. A avaliação da espessura muscular do quadríceps foi realizada em dois pontos de referência e quantificada com ultrassom portátil em modo B em dois voluntários saudáveis. Para padronização das medidas e validação das coletas das imagens, foi realizada capacitação da equipe por meio de treinamentos com aulas teóricas e práticas, com carga horária de 6 horas.

Resultados:

Foram examinadas 112 imagens pelo treinador e comparadas com os alunos. A correlação de Person encontrou excelente relação entre o treinador e todos os alunos (R2 > 0,90). A melhor associação foi entre o treinador e os nutricionistas (R2 0,99; p < 0,001), e a pior, entre o treinador e alunos médicos (R2 0,92; p < 0,001). Quanto à comparação de Bland-Altman, a maior porcentagem de erro encontrada entre treinador e alunos foi de 5,12% (IC95% 3,64 - 12,37) e a menor, 1,01% (IC95% 0,72 - 2,58); o maior viés dos valores descrito foi -0,12 ± 0,19, e o menor, -0,01 ± 0,04.

Conclusão:

Os dados analisados mostraram boa correlação entre as medidas feitas pelo instrutor e alunos, mostrando que o ultrassom de músculo quadríceps é uma ferramenta viável e de fácil aplicabilidade.
ABSTRACT
ABSTRACT

Objective:

To evaluate the intra- and inter-reliability and the ease of measuring the quadriceps muscle thickness using bedside ultrasound.

Methods:

This is a prospective, observational study. The assessment of quadriceps muscle thickness was performed at two reference points and was quantified using portable B-mode ultrasound in two healthy volunteers. For standardization of measurements and validation of image collections, the team was trained through theoretical and practical classes, with a 6-hour workload.

Results:

A total of 112 images were examined by the coach and compared with the trainees. Pearson's correlation analysis found an excellent relationship between the coach and all trainees (R2 > 0.90). The best association was between the coach and the dietitians (R2 0.99; p < 0.001), and the worst association was between the coach and the medical trainees (R2 0.92; p < 0.001). In the Bland-Altman comparison, the highest error rate found between coach and trainees was 5.12% (95% confidence interval [CI] 3.64-12.37), and the lowest was 1.01% (95%CI 0.72 - 2.58); the highest bias of the values described was -0.12 ± 0.19, and the lowest was -0.01 ± 0.04.

Conclusion:

The data analyzed showed a good correlation between the measurements made by the coach and trainees, indicating that ultrasound of the quadriceps muscle is a viable and easily applicable tool.
Subject(s)


Full text: Available Collection: International databases Database: LILACS Main subject: Ultrasonography / Point-of-Care Systems / Quadriceps Muscle Type of study: Diagnostic study / Observational study / Risk factors Limits: Adult / Female / Humans / Male Language: Portuguese Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2017 Document type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Israelita Albert Einstein/BR

Full text: Available Collection: International databases Database: LILACS Main subject: Ultrasonography / Point-of-Care Systems / Quadriceps Muscle Type of study: Diagnostic study / Observational study / Risk factors Limits: Adult / Female / Humans / Male Language: Portuguese Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2017 Document type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Israelita Albert Einstein/BR
...