Fractura de cuello femoral en trauma de alta energía: ¿podemos confiar en la tomografía computarizada multicorte? caso clínico / High energy femoral neck fracture: can we trust the computerized tomography scan? case report
Rev. chil. ortop. traumatol
; 57(3): 95-100, sept.-dic. 2016. ilus
Article
in Es
| LILACS
| ID: biblio-909776
Responsible library:
CL1.1
RESUMEN
Las fracturas asociadas de diáfisis y cuello femoral son lesiones infrecuentes. A pesar de ser una asociación conocida, es pasada por alto entre un 19-31% de las veces. A continuación presentamos un caso de una fractura de diáfisis femoral en la cual la tomografía computarizada inicial no evidenció ningún rasgo a nivel del cuello femoral; sin embargo, este rasgo se hizo presente en las imágenes de control. Existen diversos exámenes para reconocer las fracturas de cuello femoral asociadas a diáfisis femoral, como la radiografía y la tomografía computarizada. Sin embargo, a pesar de estas imágenes, pueden no ser diagnosticadas. Con este caso reafirmamos la necesidad del uso de imágenes preoperatorias e intraoperatorias en pacientes con fracturas de diáfisis femoral de alta energía y que la tomografía computarizada multicorte de ingreso puede no evidenciar fracturas mínimamente desplazadas del cuello femoral.
ABSTRACT
Simultaneous fractures of the neck and shaft of the femur are uncommon injuries. Despite it being a known combination, it is overlooked in between 19 and 31% of cases. This case report describes a femoral shaft fracture in which the initial computed tomography did not show the femoral neck fracture, although it was present in the follow-up images. There are different imaging techniques to recognise femoral neck fractures associated with femoral shaft fractures, such as radiography and computed tomography. However, despite these images, they cannot be diagnosed. This case re-affirms the need for using imaging techniques before and during the operation in patients presenting with high energy femoral shaft fractures, in order to look for an associated femoral neck fracture. Although the use of fine-cut computed tomography scan may improve the diagnostic accuracy of this test, some femoral neck fractures will still go under-diagnosed.
Key words
Full text:
1
Collection:
01-internacional
Database:
LILACS
Main subject:
Tomography, X-Ray Computed
/
Femoral Neck Fractures
Limits:
Adolescent
/
Female
/
Humans
Language:
Es
Journal:
Rev. chil. ortop. traumatol
Journal subject:
ORTOPEDIA
/
TRAUMATOLOGIA
Year:
2016
Document type:
Article
Affiliation country:
Chile
Country of publication:
Chile