Dureza e grau de conversão de resinas polimerizadas por halógeno e LED / Hardness and degree of conversion of composite polymerized with halogen and LED
Full dent. sci
; 8(32): 90-95, 2017. tab, graf
Article
in Pt
| BBO
| ID: biblio-916257
Responsible library:
BR1264.1
RESUMO
Este estudo objetivou determinar a dureza Vickers e o grau de conversão de uma resina composta polimerizadas por halógeno e LED em diferentes profundidades (2,0 e 3,0 mm). Foram utilizados os aparelhos XL3000 (halógeno - 3M) e Bright Lec (LED - MM Optics). Os corpos de prova mediam 2 e 3 mm de altura e foram divididos em 4 grupos (n=8). G1 2 mmhalógeno; G2 2 mm-LED; G3 3 mm-halógeno e G4 3 mm-LED. Os corpos de prova foram submetidos ao teste de dureza Vickers, sendo que cada amostra recebeu cinco indentações (200 g durante 6 segundos), e foi medido o grau de conversão com o espectrômetro de infravermelho (Fourier). A média dos resultados da dureza Vickers (G1 33,64; G2 26,60; G3 22,71; e G4 15,46) foi submetida à análise estatística (ANOVA), e não apresentaram diferença estatisticamente significante na profundidade de 2 mm. Na profundidade de 3 mm a tecnologia halógena apresentou resultado estatisticamente superior à tecnologia LED (p<0,05). Os dados obtidos no espectrômetro de infravermelho foram submetidos à análise estatística (testes T). Os resultados do grau de conversão não diferiram estatisticamente. As médias de grau de conversão foram G1 65,9%; G2 66,0%; G3 68,4% e G4 67,5%. Assim, conclui-se que a dureza diminuiu com o aumento da profundidade para as diferentes tecnologias emissoras de luz, e na profundidade de 3,0 mm o aparelho halógeno apresentou resultado superior ao aparelho LED. O grau de conversão não foi afetado pela profundidade e pela emissão de luz (AU).
ABSTRACT
This study aimed to evaluate the Vickers hardness and the degree of conversion of a resin composite cured by two polymerized with different technology of emission of light (halogen and LED) in different depth (2 and 3 mm). Devices were used XL3000 (halogen - 3Mâ) and Bright Lec (LED - MM Optics). The specimens measured 2 and 3 mm in height and were divided into 4 groups (n = 8). G1 2 mm-halogen; G2 2 mm-LED; G3 3 mm-halogen; and G4 3 mm-LED. The samples were submitted to Vickers hardness test, each sample received five indentations (200 g for 6 seconds), and measured the degree of conversion with the infrared spectrometer (Fourier). The average of the results of Vickers hardness (G1 33.64; G2 26.60; G3 22.71; and G4 15.46) was subjected to statistical analysis (ANOVA) and showed no statistically significant difference at a depth of 2 mm. In the depth of 3 mm halogen technology presented was statistically superior to LED (p <0.05). Data from the infrared spectrometer have been subjected to statistical analysis (T test). The results of the degree of conversion did not differ statistically. The average degree of conversion was G1 65.9%; G2 66.0%; G3 68.4%; and G4 67.5%. It was concluded that the hardness decreased with increasing depth for the different technologies emitting light, and 3.0 mm in depth of the halogen unit provides results superior to the LED device. The degree of conversion was not affected by the depth and light emission (AU).
Key words
Full text:
1
Collection:
06-national
Database:
BBO
Main subject:
Composite Resins
/
Light-Curing of Dental Adhesives
/
Hardness
Country/Region as subject:
America do sul
/
Brasil
Language:
Pt
Journal:
Full dent. sci
Year:
2017
Document type:
Article