Punción biopsia hepática percutánea en pacientes con trastornos de hemostasia. Nueva técnica. / [Percutaneous hepatic biopsy puncture in patients with hemostasis disorders. A new technique]
Bruno, M A; Rodríguez Fuchs, C; Gallo, J; González Boix, J.
Affiliation
  • González Boix, J; División Gastroenterología, Policlínica Bancaria, Buenos Aires, Argentina..
Acta gastroenterol. latinoam ; Acta gastroenterol. latinoam;20(1): 25-30, 1990.
Article in Es | BINACIS | ID: bin-51739
Responsible library: AR40.1
ABSTRACT
In order to avoid the inconveniences of the trans-jugular liver biopsy, a modified percutaneous liver biopsy with embolization has been performed in 27 patients with chronic hepatic diseases with or without hemostatic disorders. By means of a sheath and a Menghini or Tru Cut needle type, an embolization of the needle tract was carried out utilising coagulations factors (I, IIa and XIII). All procedures were laparoscopically visualised and the [quot ]Hepatic bleeding time[quot ] measured. With or without embolization, the [quot ]Hepatic bleeding time[quot ] found was 0-6 seconds and 2-6 minutes, respectively. This modified technic is a safe and effective method for high risk bleeding patients and no hemorrhagic complications postprocedure observed.