Monocyte Activation Test (MAT) as a possibility of replacement for the rabbit pyrogen test in hyperimmune sera
Utescher, Carla Lilian de Agostini; Buosi, Klariane Lais; Botosso, Viviane Fongaro; Quintilio, Wagner.
Affiliation
  • Utescher, Carla Lilian de Agostini; Instituto Butantan. Laboratório de Virologia.
  • Buosi, Klariane Lais; Instituto Butantan. Laboratório de Virologia.
  • Botosso, Viviane Fongaro; Instituto Butantan. Laboratório Especial de Biofármacos em Células Animais.
Braz. J. Pharm. Sci. ; 54(2): e17530, 2018.
Article in English | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: but-ib15417
Responsible library: BR78.1
Localization: BR78.1
ABSTRACT
The use of a commercial kit for the monocyte-activation test (MAT) was evaluated for assessing pyrogenic contamination of hyperimmune sera. Three batches of sera, two pyrogen free and one pyrogenic, were tested. Endotoxin spike recover indicated that sample dilutions from 1/2 to 1/10 are suitable. Kit transport and storage conditions were also evaluated, proving that an adequate cold chain must be assured to achieve good results. Furthermore, the commercial MAT kit seemed suitable to replace the rabbit pyrogen test (RPT) for pyrogen testing of hyperimmune sera, although further tests are needed to a full validation.
Full text: Available Collection: National databases / Brazil Database: Sec. Est. Saúde SP / SESSP-IBPROD Language: English Journal: Braz. J. Pharm. Sci. Year: 2018 Document type: Article