Your browser doesn't support javascript.
loading
Parámetros bioeléctricos in vitro e in vivo, estimados con los analizadores Bodystat® 1500-MDD y BioScan® 98 / Bioelectrical parameters in vitro and in vivo estimated with analyzers Bodystat® 1500-MDD and BioScan® 98
Universidad de Oriente; Universidad de Oriente; Hospital Infantil SurVerdecia Jarque, Manuel; Universidad de Oriente; Universidad de Oriente.
Affiliation
  • Universidad de Oriente; Universidad de Oriente. Centro Nacional de Electromagnetismo AplicadoLara Lafargue, Alcibíades. Santiago de Cuba. Cuba
  • Universidad de Oriente; Universidad de Oriente. Centro Nacional de Electromagnetismo AplicadoBergues Cabrales, Luis Enrique. Santiago de Cuba. Cuba
  • Hospital Infantil SurVerdecia Jarque, Manuel; Hospital Infantil SurVerdecia Jarque, Manuel. Santiago de Cuba. Cuba
  • Universidad de Oriente; Universidad de Oriente. Facultad de Eléctrica. Departamento de Ingeniería BiomédicaLaurencio Martínez, Yanetsy. Santiago de Cuba. Cuba
  • Universidad de Oriente; Universidad de Oriente. Centro Nacional de Electromagnetismo AplicadoOrtega Díaz, Yadenis. Santiago de Cuba. Cuba
Medisan ; 17(9)sept. 2013. ilus, tab
Article in Spanish | CUMED | ID: cum-54683
Responsible library: CU418.1
RESUMEN
Se efectuó un estudio comparativo de 2 analizadores comerciales de bioimpedancia eléctrica corporal (Bodystat® 1500-MDD y BioScan®98) en el Servicio de Oncopediatría del Hospital Infantil Sur de Santiago de Cuba, desde septiembre hasta octubre del 2009, para lo cual se realizó una simulación in vitro con los calibradores de cada equipo y un estudio in vivo de 32 adultos aparentemente sanos y 32 niños con diferentes afecciones. La resistencia eléctrica y la reactancia capacitiva se estimaron con ambos analizadores; además, se calcularon el módulo de impedancia y el ángulo de fase. La prueba t-student de 2 medias para muestras apareadas y el método de Bland-Altman fueron los criterios estadísticos usados. No existieron diferencias significativas entre ambos analizadores al introducir los factores de corrección para la resistencia eléctrica y la reactancia capacitiva; por tanto, es posible usarlos indistintamente para caracterizar bioeléctricamente a los individuos aparentemente sanos y pacientes con diferentes enfermedades(AU)
ABSTRACT
A controlled trial with 2 body electrical impedance commercial analyzers was carried out (Bodystat® 1500-MDD and BioScan®98) at the Pediatric Oncology Department of the Southern Children Hospital in Santiago de Cuba, from September to October 2009, for which an in vitro simulation with gauges of each device and an in vivo study in 32 apparently healthy adults and 32 children with different conditions were conducted. Electrical resistance and capacitive reactance were estimated with both analyzers, and impedance module and phase angle were also calculated. The two-means Student's t test for paired samples and the Bland-Altman method were used as statistical criteria. There were not significant differences between the two analyzers by introducing correction factors for electrical resistance and capacitive reactance; therefore, it is possible to use either to characterize bioelectrically apparently healthy individuals and patients with different conditions(AU)
Subject(s)

Full text: Available Collection: National databases / Cuba Database: CUMED Main subject: Bioelectric Energy Sources / Body Composition / Oncology Service, Hospital / Electric Impedance Type of study: Observational study Limits: Adult / Child / Female / Humans / Male Language: Spanish Journal: Medisan Year: 2013 Document type: Article Institution/Affiliation country: Hospital Infantil SurVerdecia Jarque, Manuel/Cuba / Universidad de Oriente/Cuba
Full text: Available Collection: National databases / Cuba Database: CUMED Main subject: Bioelectric Energy Sources / Body Composition / Oncology Service, Hospital / Electric Impedance Type of study: Observational study Limits: Adult / Child / Female / Humans / Male Language: Spanish Journal: Medisan Year: 2013 Document type: Article Institution/Affiliation country: Hospital Infantil SurVerdecia Jarque, Manuel/Cuba / Universidad de Oriente/Cuba
...