Comprobación de la posición del tubo endotraqueal mediante ecografía clínica / Assessment of endotracheal tube positioning by point- of-care ecography
Díaz Águila, Héctor R.
Affiliation
  • Díaz Águila, Héctor R; Hospital Provincial Docente Mártires del 9 de Abril.Sagua la Grande.Villa Clara.Cuba. Villa Clara. CU
Gac. méd. espirit ; 19(1): 80-86, ene.-abr. 2017.
Article in Spanish | CUMED | ID: cum-73680
Responsible library: CU1.1
RESUMEN
Fundamento La intubación traqueal es el segundo procedimiento invasivo más utilizado en pacientes graves. Se han utilizado varios métodos para la comprobación de la intubación traqueal de forma satisfactoria, entre ellas la auscultación pulmonar, la capnografía, estudio radiológico y ecografía. Presentación de caso Se presentó un caso que acudió al servicio de urgencias, por disnea intensa, se requirió atención en terapia intensiva y se realizó intubación rápida orotraqueal guiada por ecografía, método no utilizado habitualmente en Cuba y de que no se ha encontrado publicación alguna con anterioridad en revistas médicas cubanas. Se describió la técnica de intubación orotraqueal guiada por ecografía.

Conclusiones:

La intubación orotraqueal guiada por ecografía es un procedimiento seguro, fiable y repetible, además de verificar la correcta permanencia y posición adecuada del tubo endotraqueal.
ABSTRACT

Background:

The tracheal intubation is the second invasive procedure used in critical patients. Several methods have been used for the confirmation of the tracheal intubation, among them the lung auscultation, capnography, radiological study and echography Presentation of the case A case was assisted in the emergency room complaining of intense dyspnea, intensive care was needed and a rapid orotracheal intubation guided by ecography was performed, this method was not habitually carried out in Cuba where no records in publication were found previously in Cuban medical magazines. The technique of orotracheal intubation guided by ecography was carried out.

Conclusions:

The technique of orotracheal intubation guided by ecography is a safe, reliable and repeatable procedure, it also verifies the correct permanence and adequate position of orotracheal tube.
Subject(s)

Full text: Available Collection: National databases / Cuba Database: CUMED Main subject: Intubation, Intratracheal Type of study: Diagnostic study Limits: Humans Language: Spanish Journal: Gac. méd. espirit Year: 2017 Document type: Article Institution/Affiliation country: Hospital Provincial Docente Mártires del 9 de Abril.Sagua la Grande.Villa Clara.Cuba/CU
Full text: Available Collection: National databases / Cuba Database: CUMED Main subject: Intubation, Intratracheal Type of study: Diagnostic study Limits: Humans Language: Spanish Journal: Gac. méd. espirit Year: 2017 Document type: Article Institution/Affiliation country: Hospital Provincial Docente Mártires del 9 de Abril.Sagua la Grande.Villa Clara.Cuba/CU
...