Your browser doesn't support javascript.
loading
Valor de los signos de cápsula interna en la estimulación del núcleo subtalámico de la enfermedad de Parkinson / The value of the internal capsule signs in the stimulation of the subthalamic nucleus in Parkinson’s disease
Escamilla, F; Mínguez, A; Jouma-Katati, M; Meersmans Sánchez-Jofré, M; Arnáiz-Urrutia, A; Martín-Linares, J. M ; Ortega-Moreno, A; Arjona-Morón, V.
Affiliation
  • Escamilla, F; Hospital Universitario Virgen de las Nieves. Granada. España
  • Mínguez, A; Hospital Universitario Virgen de las Nieves. Granada. España
  • Jouma-Katati, M; Hospital Universitario Virgen de las Nieves. Granada. España
  • Meersmans Sánchez-Jofré, M; Hospital Universitario Virgen de las Nieves. Granada. España
  • Arnáiz-Urrutia, A; Hospital Universitario Virgen de las Nieves. Granada. España
  • Martín-Linares, J. M ; Hospital Universitario Virgen de las Nieves. Granada. España
  • Ortega-Moreno, A; Hospital Universitario Virgen de las Nieves. Granada. España
  • Arjona-Morón, V; Hospital Universitario Virgen de las Nieves. Granada. España
Rev. neurol. (Ed. impr.) ; 41(4): 193-197, 16 ago., 2005. tab, graf
Article in Es | IBECS | ID: ibc-040672
Responsible library: ES1.1
Localization: ES1.1 - BNCS
RESUMEN
Introducción. La eficacia de la estimulación del núcleo subtalámico (ECP-NST) en la enfermedad de Parkinson (EP) avanzada depende en gran medida de la correcta implantación de los electrodos. Como la región sensitivomotora del NST está junto a la cápsula interna (CI), pensamos que la eficacia motora de ECP-NST podría relacionarse con el umbral de estimulación en el que aparecen signos de CI (umbral de CI). Pacientes y métodos. En 17 pacientes consecutivos con EP avanzada intervenidos mediante ECP-NST bilateral (uno unilateral) determinamos la mejoría motora en cada lado del cuerpo (n = 33) y el consumo de energía un año después de la cirugía en función del umbral de CI obtenido durante la programación. Resultados. Hubo una mejoría de un 45% en la UPDRS III en off y un 24% de descenso en la dosis equivalente de levodopa con la ECP-NST bilateral. Cuando consideramos los electrodos hubo una mejoría estadísticamente significativa que era dependiente del umbral de CI. El consumo energético difirió significativamente entre los electrodos con un umbral de CI 3-7 voltios (1,5 ± 1,2 mW) y aquéllos con un umbral de CI > 7 voltios (8,3 ± 9,4 mW). Conclusión. Durante la fase de estimulación y tras una correcta localización del NST, mediante registro neurofisiológico, el umbral de CI tiene implicaciones pronósticas en la eficacia motora a medio-largo plazo y en el consumo de la batería del generador (AU)
ABSTRACT
The effectiveness of stimulating the subthalamic nucleus (DBS-STN) in advanced Parkinson’s disease (PD) largely depends on the correct placement of the electrodes. Since the sensory-motor region of the STN lies beside the internal capsule (IC), we believe that the motor effectiveness of DBS-STN could be related to the stimulation threshold in which IC signs appear (IC threshold). Patients and methods. An examination of 17 consecutive patients with advanced PD who had been submitted to bilateral DBS-STN (one case was unilateral) was carried out to determine the motor improvement on each side of the body (n = 33) and the energy consumption one year after surgery according to the IC threshold obtained during the programming. Results. A 45% improvement was observed in the UPDRS III in off and there was a 24% reduction in the equivalent dose of levodopa with bilateral DBS-STN. When the electrodes were considered, there was a statistically significant improvement that depended on the IC threshold. Energy consumption differed significantly between electrodes with an IC threshold of 3-7 V (1.5 ± 1.2 μW) and those with an IC threshold > 7 V (8.3 ± 9.4 μW). Conclusions. During the stimulation phase and following the correct location of the STN, which was achieved by neurophysiological recording, the IC threshold has prognostic implications in mediumlong term motor effectiveness and in the consumption of the battery in the generator (AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Parkinson Disease / Electric Stimulation Therapy Type of study: Diagnostic study Aspects: Patient-preference Limits: Humans Language: Spanish Journal: Rev. neurol. (Ed. impr.) Year: 2005 Document type: Article Institution/Affiliation country: Hospital Universitario Virgen de las Nieves/España
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Parkinson Disease / Electric Stimulation Therapy Type of study: Diagnostic study Aspects: Patient-preference Limits: Humans Language: Spanish Journal: Rev. neurol. (Ed. impr.) Year: 2005 Document type: Article Institution/Affiliation country: Hospital Universitario Virgen de las Nieves/España
...