RESUMEN

Objetivo:

Comparar los distintos métodos de estimación del poder refractivo de la córnea para el cálculo la lente intra-ocular (LIO) para la cirugía de cataratas después de cirugía refractiva corneal.

Método:

Revisión de la literatura médica y de series de casos clínicos.

Resultados:

Para el cálculo más exacto de la LIO necesitamos la queratométría previa (Kpre) y posterior (Kpost) a la cirugía refractiva si utilizamos una fórmula de 3.ª generación o solamente la Kpost si optamos por una fórmula de 4.ª generación.

Conclusiones:

Previamente a la cirugía refractiva es conveniente registrar la refracción y queratometría (K y método). Se recomienda utilizar fórmulas de 3.ª generación con la corrección doble-k de Aramberri o fórmulas de 4.ª generación
ABSTRACT

Purpose:

To compare various methods of estimating corneal power for IOL calculation for cataract surgery after corneal refractive surgery.

Methods:

Review of the medical literature and case reports.

Results:

For more accurate IOL power calculations we need pre- (Kpre) and post-treatment keratometry records (Kpost) if using 3rd generation formulae, or Kpost records when using 4th generation formulae.

Conclusions:

Prior to performing a keratorefractive procedure it is advisable to have pre-treatment refraction and keratometry (K and method) registered. 3rd generation formulae with Aramberri’s double-K correction, or 4th generation formulae are recommended
Subject(s)
Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Optics and Photonics / Lenses, Intraocular Limits: Humans Language: Spanish Journal: Arch. Soc. Esp. Oftalmol Year: 2005 Document type: Article Institution/Affiliation country: Hospital Universitari Bellvitge/España
Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Optics and Photonics / Lenses, Intraocular Limits: Humans Language: Spanish Journal: Arch. Soc. Esp. Oftalmol Year: 2005 Document type: Article Institution/Affiliation country: Hospital Universitari Bellvitge/España
...