Your browser doesn't support javascript.
loading
Determinación por cromatografía de líquidos y estudio farmacocinético del sulfato de salbutamol en el plasma de conejo / Liquid chromatographic determination and pharmacokinetics study of salbutamol sulphate in rabbit plasma
Sutariya, V. B; Mashru, R. C; Sankalia, M. G; Sankalia, J. M.
Affiliation
  • Sutariya, V. B; The M.S. University of Baroda. Center of relevance and excellence in NDDS. G.H. Patel building. Gujarat. India
  • Mashru, R. C; The M.S. University of Baroda. Center of relevance and excellence in NDDS. G.H. Patel building. Gujarat. India
  • Sankalia, M. G; The M.S. University of Baroda. Center of relevance and excellence in NDDS. G.H. Patel building. Gujarat. India
  • Sankalia, J. M; The M.S. University of Baroda. Center of relevance and excellence in NDDS. G.H. Patel building. Gujarat. India
Ars pharm ; 47(2): 185-197, 2006. ilus, tab
Article in Es | IBECS | ID: ibc-048974
Responsible library: ES1.1
Localization: ES1.1 - BNCS
RESUMEN
Desarrollar y validar un método de cromatografía de líquidos de alto rendimiento (HPLC) exacto, preciso, específico y sencillo con detección de UV para la determinación de sulfato de salbutamol en el plasma de conejo. Se agregó estándar interno (cloramfenicol) a 0,5 ml de plasma de conejo. Se extrajeron sulfato de salbutamol y cloramfenicol en 5 ml de di(2-etilhexil) fosfato 0,1 M en cloroformo. La fase de cloroformo se trató con ácido clorhídrico 0,5 M y se analizó una alícuota de fase acídica mediante un sistema de HPLC de fase inversa equipado con una columna analítica C18 de 4,6 × 250 mm i. d. y detección de UV (landa = 276 nm). La fase móvil consistió en agua (70%), metanol (20%) y acetonitrilo (10%), y su velocidad de flujo fue de 1,2 ml/min. No se detectaron picos de interferencia de componentes endógenos en los cromatogramas de plasma sin aditivos. El fármaco y el estándar interno se elucionaron a 3,0 y 15,4 minutos, respectivamente. La proporción del área pico fármaco/estándar fue lineal frente a la relación de concentración del fármaco que resultó ser lineal (r=0,992) sobre 100-1500 ng/ml. La eficacia de la extracción fue superior al 80,00% y la concentración de cuantifi cación mínima fue 100 ng/ml (CV<10%) basada en 500 ìl de plasma. El coeficiente intradía de variación (CV) osciló entre el 1,9 y el 6,2%, y el interdía osciló entre el 1,1 y el 8,9%. El porcentaje de recuperación de sulfato de salbutamol en plasma osciló entre el 98,97 y el 102,41%. El ensayo fue sencillo, sensible, preciso y exacto para su uso en estudios farmacocinéticos del sulfato de salbutamol en conejos. El método mencionado se utilizó para estudiar la farmacocinética de los comprimidos convencionales, los comprimidos de disolución rápida y el recubrimiento de sulfato de salbutamol de disolución rápida después de la administración oral a conejos
ABSTRACT
To develop and validate a simple, specifi c, precise and accurate HPLC method with UV detection for the determination of salbutamol sulphate in rabbit plasma. To 0.5 ml of rabbit plasma internal standard (chloramphenicol) was added. Salbutamol sulphate and chloramphenicol were extracted to 5 ml of 0.1 M-bis-(2 ethyl hexyl) phosphate in chloroform. The chloroform phase was treated with 0.5 M hydrochloric acid and an aliquot of the acidic phase was analyzed by a reverse phase HPLC system equipped with 4.6 × 250 mm i. d. C18 analytical column and UV detection landa = 276 nm). Mobile phase consisted of water (70%), methanol (20%) and acetonitrile (10%) and its fl ow rate was 1.2 ml/min. There were no interfering peaks from endogenous components in blank plasma chromatograms. The drug and internal standard eluted at 3.0 and 15.4 min, respectively. The peak drug/IS area ratio was linear versus drug concentration relationship was linear (r=0.992) over 100-1500ng/ml. The extraction efficiency was greater than 80.00% and minimum quantification concentration was 100 ng/ml (CV<10%) based on 500ìl of plasma. The intraday coefficient of variation (CV) ranged from 1.9 to 6.2% and interday varied from 1.1 to 8.9 %. The % recovery of salbutamol sulphate in plasma range from 98.97 to 102.41%. The assay was simple, sensitive, precise and accurate for the use in pharmacokinetic studies of salbutamol sulphate in the rabbit. The mentioned method was used to study the pharmacokinetics of conventional tablets, fast dissolving tablets and fast dissolving film of salbutamol sulphate after oral administration in rabbits
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Plasma / Chromatography / Chromatography, High Pressure Liquid / Albuterol Limits: Animals Language: Spanish Journal: Ars pharm Year: 2006 Document type: Article Institution/Affiliation country: The M.S. University of Baroda/India
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Plasma / Chromatography / Chromatography, High Pressure Liquid / Albuterol Limits: Animals Language: Spanish Journal: Ars pharm Year: 2006 Document type: Article Institution/Affiliation country: The M.S. University of Baroda/India
...