Influencia de la intensidad de estimulación del catéter femoral sobre analgesia postoperatoria tras prótesis de rodilla / Influence of femoral catheter stimulation intensity on post-surgical analgesia after total knee replacement
Ortiz de la Tabla González, R; Martínez Navas, Á.
Affiliation
  • Ortiz de la Tabla González, R; Hospital Universitario de Valme. Sevilla. España
  • Martínez Navas, Á; Hospital Universitario de Valme. Sevilla. España
Rev. esp. anestesiol. reanim ; 59(4): 187-196, abr. 2012.
Article in Spanish | IBECS | ID: ibc-100368
Responsible library: ES1.1
Localization: BNCS
RESUMEN
Introducción. Nuestro objetivo fue comprobar si distintas intensidades de neuroestimulación con el catéter estimulador a nivel del nervio femoral, influyen en la adecuación de la analgesia postoperatoria durante las primeras 48h del postoperatorio tras prótesis total de rodilla. Los catéteres estimuladores permiten posicionar la punta del catéter en la proximidad del nervio y, por tanto, reducir la cantidad de anestésico local necesaria para un bloqueo con éxito. En la actualidad, está debatida cuál es la intensidad de estimulación a la que se deben colocar para proporcionar analgesia adecuada, aunque parece ser que si se obtiene con 1mAmp o menos, el bloqueo es más efectivo. Material y métodos. Estudio comparativo, prospectivo y aleatorizado en pacientes intervenidos de prótesis total de rodilla. Tras la cirugía con anestesia subaracnoidea, se realizó un bloqueo femoral continuo con un catéter estimulador a una intensidad de neuroestimulación de entre 0,2 y 0,5mAmp en el grupo 1, entre 0,6 y 1mAmp en el grupo 2, igual o superior a 1,1mAmp en el grupo 3, y en el grupo 4 se introdujo el catéter entre 3-5cm sin buscar respuesta motora. Se administró a través del catéter ropivacaína 0,2% 0,4mL/kg y perfusión a 5mL/h, con bolos de 10mL/30min. En todos los pacientes se efectuó también un bloqueo del nervio ciático con 20ml de ropivacaína 0,5%. Se registraron los datos demográficos de los pacientes, características de la analgesia postoperatoria, bloqueo sensitivo y motor en cada territorio, bolos solicitados y administrados, analgesia de rescate y efectos indeseables a las 8, 16, 24, 36 y 48h. Resultados. Se incluyó a 124 pacientes, 32 en grupo 1 (25,8%), 21 en grupo 2 (16,9%), 31 en grupo 3 (25%) y 40 en grupo 4 (32,3%). Los 4 grupos fueron homogéneos respecto a edad, talla, peso y ASA. En el dolor postoperatorio no se encontraron diferencias estadísticamente significativas, excepto durante el movimiento a las 36h en el territorio femoral (p=0,032). También se encontraron diferencias estadísticamente significativas en el bloqueo sensitivo en territorio femoral a las 48h (p=0,019) y en el femorocutáneo a las 8 (p=0,049) y a las 24h (p=0,045). Con relación al bloqueo motor, tan solo se encontraron diferencias en el nervio obturador a las 24h (p=0,016). No hubo diferencias en la analgesia de rescate, bolos PCA solicitados y administrados, excepto en el número de bolos solicitados a las 16h, que fueron menores en el grupo 3 (p= 0,049). Tampoco hubo diferencias significativas en los efectos indeseables ni en el grado de satisfacción de los pacientes entre los 4 grupos. Conclusiones. En nuestro estudio, no se ha encontrado influencia de la intensidad de neuroestimulación a la que responde el sistema neuromuscular implicado cuando se coloca un catéter estimulador a nivel femoral sobre la analgesia que proporciona tras la cirugía protésica de rodilla(AU)
ABSTRACT
Introduction. Stimulating catheters allow the catheter point to be positioned near the nerve, thus reducing the amount of local anaesthetic required for a successful block. There is currently a debate on what is the stimulation intensity required to provide adequate analgesia, although it does seem that if it is obtained with 1mAmp or less the block is more effective. The objective of the study was to demonstrate whether different neurostimulation intensities with the stimulating catheter at femoral nerve level, had an influence on the adequacy of post-surgical analgesia during the 48h after total knee arthroplasty. Material and methods. A comparative, prospective and randomised study was conducted on patients subjected to total knee replacement. After surgery with subarachnoid anaesthesia, a continuous femoral block was performed with a stimulating catheter at a neurostimulation intensity 0.2 and 0.5mAmp in Group 1, between 0.6 and 1mAmp in Group 2, equal or higher than 1.1mAmp in Group 3, and in Group 4 the catheter was introduced between 3-5cm without looking for a motor response. A dose of 0.2% ropivacaine 0.4mL/kg and an infusion at 5mL/h, with boluses of 10mL/30min, was administered via the catheter. Sciatic nerve block was also performed on all patients with 20ml of 0.5% ropivacaine. The patient demographics were recorded, as well as, post-surgical analgesia details, sensory and motor block in each area, boluses requested, rescue analgesia, and undesirable effects at 8, 16, 24, 36 and 48h. Results. A total of 124 patients were included, 32 in Group 1 (25.8%), 21 in Group 2 (16.9%), 31 in Group 3 (25%), and 40 in group 4 (32.3%). The 4 groups were homogeneous as regards age, height, weight and ASA. There were no statistically significant differences found in the post-operative pain, except during movement in the femoral area at 36hours (p=.032). There were also no statistically significant differences found in the sensory block in the femoral area at 48hours (p=.019) and in the femoral cutaneous nerve block at 8hours (p=.049) or at 24hours (p=.045). As regards motor block, differences were only found in the obturator nerve at 24hours (p=.016). There were no differences in rescue analgesia, patient controlled analgesia (PCA) boluses requested or administered, except that the number of boluses requested at 16hours was less in Group 3 (p=.049). There were also no significant differences in undesirable effects or in the level of satisfaction of the patients between the four groups. Conclusions. In our study, no influence was found on the level of analgesia provided after knee replacement surgery with the neurostimulation intensity to which the neuromuscular system involved responded when a stimulating catheter is inserted at femoral level(AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Catheters / Implantable Neurostimulators / Analgesia / Knee Prosthesis Type of study: Controlled clinical trial / Observational study Limits: Female / Humans / Male Language: Spanish Journal: Rev. esp. anestesiol. reanim Year: 2012 Document type: Article Institution/Affiliation country: Hospital Universitario de Valme/España
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Catheters / Implantable Neurostimulators / Analgesia / Knee Prosthesis Type of study: Controlled clinical trial / Observational study Limits: Female / Humans / Male Language: Spanish Journal: Rev. esp. anestesiol. reanim Year: 2012 Document type: Article Institution/Affiliation country: Hospital Universitario de Valme/España
...