Your browser doesn't support javascript.
loading
Valor diagnóstico del cociente de cadenas ligeras libres de inmunoglobulinas en suero en las gammapatías monoclonales de significado incierto / Diagnostic value of serum immunoglobulin free light chains ratio in monoclonal gammopathies of undetermined significance
Bermudo, Carmen; Cárdenas, M. Cruz; Cortés, Mariano; Fernández, María; Martínez-Brú, Cecília; Pérez Surribas, David; Rodríguez, Teresa; Valldecabres, Carmen; Viedma, José Antonio; Zapico, Edgar.
Affiliation
  • Bermudo, Carmen; Hospital Universitario Virgen Macarena. Sevilla. España
  • Cárdenas, M. Cruz; Hospital Clínico San Carlos. Madrid. España
  • Cortés, Mariano; Hospital Universitari Santa Creu i Sant Pau. Barcelona. España
  • Fernández, María; Hospital Carmen y Severo Ochoa. España
  • Martínez-Brú, Cecília; Hospital Universitari Santa Creu i Sant Pau. Barcelona. España
  • Pérez Surribas, David; Laboratori Pasteur. Andorra la Vella. Andorra
  • Rodríguez, Teresa; Hospital Universitario Gran Canaria Dr. Negrín. Las Palmas de Gran Canaria. España
  • Valldecabres, Carmen; Hospital Universitario La Ribera. Alzira. España
  • Viedma, José Antonio; Hospital General y Universitario de Elche. Elche. España
  • Zapico, Edgar; Hospital Universitari Santa Creu i Sant Pau. Barcelona. España
Rev. lab. clín ; 5(3): 111-115, jul.-sept. 2012. tab, ilus
Article in Spanish | IBECS | ID: ibc-105598
Responsible library: ES1.1
Localization: BNCS
RESUMEN
Introducción. La medida de la concentración de las cadenas ligeras libres de inmunoglobulinas en suero proporciona información clínicamente relevante en el diagnóstico, pronóstico y monitorización de pacientes con mieloma múltiple (MM) y con gammapatías monoclonales de significado incierto (GMSI). En este trabajo se ha calculado el valor predictivo negativo (VPN) del cociente kappa/lambda libres (kappa/lambda) en un suero incluido dentro del rango diagnóstico (0,26-1,65), además de establecer unos nuevos valores discriminantes con un VPN del 100% en el grupo de pacientes estudiado. Material y métodos. La medida de la concentración de cadenas ligeras libres en suero se realizó por nefelometría en 157 muestras de pacientes diagnosticados de MM o GMSI y se calculó el cociente kappa/lambda libres. Resultados. El área bajo la curva de rendimiento diagnóstico para el cociente kappa/lambda libres fue de 0,885 en los pacientes con gammapatías con isotipo kappa y 0,879 en pacientes con gammapatías con isotipo lambda. El VPN para un cociente kappa/lambda libres entre 0,26 y 1,65 fue del 92%. Utilizando un intervalo de 0,36-1,0 se alcanzó un VPN del 100%. Conclusiones. La modificación del rango diagnóstico de 0,26-1,65 del cociente kappa/lambda libres por el comprendido entre 0,36 y 1,0, podría ser útil para obviar la realización de un aspirado de médula ósea en pacientes con criterios clínicos y analíticos de GMSI (AU)
ABSTRACT
Background. Measurement of immunoglobulin free light chains provides relevant clinical information for the diagnosis, prognosis and monitoring of multiple myeloma (MM) and monoclonal gammopathies of undetermined significance (MGUS). We evaluated the negative predictive value (NPV) of a serum free kappa to lambda (kappa/Lambda) ratio included within the described reference range (0.26-1.65) and also set cut-off points for the ratio in order to ensure a 100% NPV. Methods. Serum concentration of free light chains was measured by nephelometry in 157 individuals diagnosed as having MM or MGUS, and the free kappa/Lambda ratio was calculated. Results. The area under the curve of the free kappa/lambda ratio was 0.885 in the kappa type gammopathies subgroup, and 0.879 for the lambda subgroup. The NPV for a free kappa/lambda ratio between 0.26 and 1.65 was 92%. Using cut-off points of 0.36 and 1.0 for the ratio, achieved a 100% NPV. Conclusions. A change from the cut-off point 0.26-1.65 to 0.36-1.0 for the free kappa/lambda ratio could be useful in order to avoid performing a bone marrow aspirate in patients with MGUS clinical and laboratory criteria (AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Paraproteinemias / Predictive Value of Tests / Immunoglobulin kappa-Chains / Immunoglobulin Light Chains / Nephelometry and Turbidimetry Type of study: Diagnostic study / Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Rev. lab. clín Year: 2012 Document type: Article Institution/Affiliation country: Hospital Carmen y Severo Ochoa/España / Hospital Clínico San Carlos/España / Hospital General y Universitario de Elche/España / Hospital Universitari Santa Creu i Sant Pau/España / Hospital Universitario Gran Canaria Dr. Negrín/España / Hospital Universitario La Ribera/España / Hospital Universitario Virgen Macarena/España / Laboratori Pasteur/Andorra
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Paraproteinemias / Predictive Value of Tests / Immunoglobulin kappa-Chains / Immunoglobulin Light Chains / Nephelometry and Turbidimetry Type of study: Diagnostic study / Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Rev. lab. clín Year: 2012 Document type: Article Institution/Affiliation country: Hospital Carmen y Severo Ochoa/España / Hospital Clínico San Carlos/España / Hospital General y Universitario de Elche/España / Hospital Universitari Santa Creu i Sant Pau/España / Hospital Universitario Gran Canaria Dr. Negrín/España / Hospital Universitario La Ribera/España / Hospital Universitario Virgen Macarena/España / Laboratori Pasteur/Andorra
...