Eficacia y seguridad de un hemostático local de tercera generación y precursores en cirugía vascular. Revisión de la literatura / Efficacy and safety of a third generation local haemostatic and precursors in vascular surgery: A review of the literature
Angiología
; 64(6): 239-246, nov.-dic. 2012. tab
Article
in Spanish
| IBECS
| ID: ibc-107727
Responsible library:
ES1.1
Localization: BNCS
RESUMEN
El control de la hemostasia y el sellado tisular son 2 aspectos cruciales en cualquier proceso quirúrgico. Los hemostáticos locales selladores de fibrina contribuyen a disminuir el riesgo de sangrado favoreciendo la coagulación y además, agentes como TachoSil® (TS), poseen propiedades sellantes que refuerzan las suturas quirúrgicas, especialmente las vasculares, cuando las técnicas estándar son insuficientes. El objetivo principal de este trabajo es recoger la evidencia científica actual sobre la utilización de TS en procesos quirúrgicos relacionados con la cirugía vascular. Para ello, se llevó a cabo una búsqueda en Medline hasta marzo de 2011. Tras las lecturas críticas, fueron incluidos 5 estudios preclínicos y 10 clínicos con diferentes grados de evidencia. El resultado de esta revisión demuestra que TS presenta propiedades hemostáticas y de refuerzo de suturas vasculares y es de utilidad su uso en cirugía con riesgo de hemorragia y que precise sellado de estructuras(AU)
ABSTRACT
The control of haemostasis and tissue sealing are two essential aspects in any surgical procedure. The local haemostatic fibrin sealants help to reduce the risk of bleeding by favouring coagulation. Furthermore, agents such as TachoSil® (TS) have sealant properties that strengthen surgical sutures, particularly vascular, when standard techniques are insufficient. The main objective of this work is to review current scientific evidence on the use of TS in surgical procedures related to vascular surgery. For this purpose, a literature search was conducted using Medline for articles published from January 1987 until March 2011. After methodological evaluation, five preclinical studies and ten clinical studies were included, according to scientific evidence levels. The result of this review shows that TS has haemostatic and vascular suture reinforcement properties. For these reasons, it is useful in surgical procedures with a risk of bleeding and which may require sealing structures(AU)
Search on Google
Collection:
National databases
/
Spain
Database:
IBECS
Main subject:
Vascular Surgical Procedures
/
Hemostatics
Limits:
Humans
Language:
Spanish
Journal:
Angiología
Year:
2012
Document type:
Article
Institution/Affiliation country:
Hospital Universitario de Salamanca/España
/
Medical Affairs, Salutis Research SL/España