Your browser doesn't support javascript.
loading
Kathon CG y Dermatología Laboral. Actualización / Kathon CG and Occupational Dermatology. An update
Rodrigues Barata, Ana Rita; Rodríguez Espinosa, Jesús; Heras Mendaza, Felipe; Conde-Salazar Gomèz, Luis.
Affiliation
  • Rodrigues Barata, Ana Rita; Hospital Universitario Virgen Macarena. Departamento de Dermatología y Venereología. Sevilla. España
  • Rodríguez Espinosa, Jesús; Fraternidad Muprespa. Ciudad Real. España
  • Heras Mendaza, Felipe; Pabellón 8 Universidad Complutense. Instituto de Salud Carlos III. Unidad de Dermatología Laboral. Madrid. España
  • Conde-Salazar Gomèz, Luis; s.af
Med. segur. trab ; 58(228): 237-245, jul.-sept. 2012. ilus
Article in Spanish | IBECS | ID: ibc-109261
Responsible library: ES1.1
Localization: BNCS
RESUMEN
El Kathon CG constituye el nombre comercial de una mezcla de isotiazolinas Metilcloroisotiazolinona y Metilisotiazolinona. Es un conservante muy utilizado, sobre todo en la industria cosmética, aunque en los últimos años también se ha impuesto su presencia en productos de limpieza de uso doméstico y actualmente a concentraciones más altas en preparados de uso industrial como aceites de corte, emulsiones de látex, pinturas al temple, aceites para motores Diesel, etc. Por su alto poder sensibilizante y amplia utilización, constituye actualmente una de las causas más frecuentes de alergia de contacto por preservativos, tanto en nuestra vida privada, como en el ámbito profesional.

Objetivos:

Estudiar la capacidad sensibilizante del Kathon CG y su relación con el desarrollo de eczema de contacto alérgico de origen profesional.

Métodos:

Estudio observacional descriptivo, a través de la revisión de las historias clínicas de los pacientes vistos en el Servicio de Dermatología Laboral del Instituto Nacional de Medicina y Seguridad en el Trabajo durante los años 2008-2012; 1520 pacientes fueron evaluados y estudiados mediante pruebas epicutáneas para descartar una posible dermatosis profesional. Se registraron los casos de sensibilización al Kathon CG y se analizaron las siguientes variables genero, edad, grupo profesional, localización de las lesiones cutáneas, relevancia y relación profesional. El análisis estadístico se realizó con el programa SPSS 15.0.

Resultados:

Se observó sensibilización al Kathon CG en 88 pacientes (5,8%), correspondiendo un 42% a sensibilizaciones de origen profesional.

Conclusiones:

La alergia de contacto profesional por Kathon CG constituye actualmente es un problema de alta prevalencia. Ante un paciente con positividad a este alérgeno hay que interrogar siempre por su profesión (AU)
ABSTRACT
Kathon CG is the tradename for a mixture of isothiazolines methylchloroisothiazolinone and methylisothiazolinone. It is a widely used preservative, especially in the cosmetic industry, although in recent years is presence have also been imposed in cleaning products for household use and, at higher concentrations in industrial preparations such as cutting oils, latex emulsions, paints, oils for diesel engines, etc. Because of its high sensitizing power and widespread use, is currently one of the most common causes of allergic contact dermatitis, both in our private lives, as in the occupational field.

Objectives:

To study the sensitizing capacity of Kathon CG and its relation to the development of allergic contact dermatitis of occupational origin.

Methods:

We performed a retrospective study by reviewing the medical records of patients seen at the Department of Occupationsal Dermatology at the Instituto Nacional de Medicina y Seguridad en el Trabajo, during the years 2008-2012. In that period, 1520 patients were evaluated and studied by patch testing, to rule out an occupational skin condition. We recorded cases of sensitization to Kathon CG and analyzed the following data gender, age, occupational group, location of skin lesions, relevance and occupational origin. Statistical analysis was performed using SPSS 15.0.

Results:

We observed sensitization to Kathon CG in 88 patients (5.8%), and 42% were of occupational origin.

Conclusions:

Occupational contact allergy to Kathon CG is currently a problem of high prevalence. In patients with sensitization to this allergen, we should always ask about their occupation (AU)
Subject(s)

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Preservatives, Pharmaceutical / Dermatitis, Contact / Additives in Cosmetics Type of study: Etiology study / Observational study / Risk factors Limits: Adolescent / Adult / Female / Humans / Male Language: Spanish Journal: Med. segur. trab Year: 2012 Document type: Article Institution/Affiliation country: Fraternidad Muprespa/España / Hospital Universitario Virgen Macarena/España / Pabellón 8 Universidad Complutense/España

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Preservatives, Pharmaceutical / Dermatitis, Contact / Additives in Cosmetics Type of study: Etiology study / Observational study / Risk factors Limits: Adolescent / Adult / Female / Humans / Male Language: Spanish Journal: Med. segur. trab Year: 2012 Document type: Article Institution/Affiliation country: Fraternidad Muprespa/España / Hospital Universitario Virgen Macarena/España / Pabellón 8 Universidad Complutense/España
...