Your browser doesn't support javascript.
loading
Electrocirugía y dispositivos electrónicos cardiacos implantables (marcapasos y desfibriladores) / Electrosurgery in Patients With Implantable Electronic Cardiac Devices (Pacemakers and Defibrillators)
García Bracamonte, B; Rodriguez, J; Casado, R; Vanaclocha, F.
Affiliation
  • García Bracamonte, B; Hospital Universitario 12 de Octubre. Servicio de Dermatología. Madrid. España
  • Rodriguez, J; Hospital Universitario 12 de Octubre. Servicio de Cardiología. Unidad de Marcapasos. Madrid. España
  • Casado, R; Hospital Universitario 12 de Octubre. Servicio de Anestesia. Madrid. España
  • Vanaclocha, F; Hospital Universitario 12 de Octubre. Servicio de Dermatología. Madrid. España
Actas dermo-sifiliogr. (Ed. impr.) ; 104(2): 128-132, mar. 2013. tab, ilus
Article in Es | IBECS | ID: ibc-109948
Responsible library: ES1.1
Localization: BNCS
RESUMEN
El electrobisturí es una herramienta muy útil y ampliamente utilizada en dermatología para el tratamiento de lesiones benignas y malignas cutáneas, y para la hemostasia durante la cirugía dermatológica. Su uso en pacientes con dispositivos electrónicos cardiacos implantables (marcapasos y desfibriladores) requiere tomar ciertas precauciones ya que puede producir interferencias electromagnéticas capaces de provocar su malfuncionamiento. Ante un paciente con uno de estos dispositivos se debe conocer el tipo de dispositivo que presenta y la dependencia del paciente, y valorar la localización tanto del dispositivo como de la lesión cutánea a tratar. El marcapasos en configuración bipolar es el más resistente a la interferencia. Se aconseja la monitorización adecuada del paciente y el uso de la pinza bipolar (AU)
ABSTRACT
The electrosurgical unit is a very useful tool widely used in dermatology to treat benign and malignant skin lesions and to achieve hemostasis during surgery. However, precautions are required when this technique is used in patients with implantable electronic cardiac devices (IECD), such as pacemakers and defibrillators, because electromagnetic interference produced by the tool may cause such devices to malfunction. Before using electrosurgery in patients with IECDs, it is essential to ascertain the type of implanted device and the patient’s level of dependence on it. The location of the skin lesion to be treated with respect to the device should also be assessed. Bipolar pacemakers are more resistant to interference. Appropriate monitoring and the use of bipolar forceps are recommended (AU)
Subject(s)
Search on Google
Collection: 06-national / ES Database: IBECS Main subject: Pacemaker, Artificial / Skin Diseases / Defibrillators, Implantable / Electrosurgery Type of study: Etiology_studies Limits: Humans Language: Es Journal: Actas dermo-sifiliogr. (Ed. impr.) Year: 2013 Document type: Article
Search on Google