Your browser doesn't support javascript.
loading
Fiabilidad y correlación en la evaluación de la movilidad de rodilla mediante goniómetro e inclinómetro / Reliability and correlation of knee range of motion measurements using goniometer and inclinometer
Gil Fernández, M; Zuil Escobar, JC.
Affiliation
  • Gil Fernández, M; Residencia de la Tercera Edad Vital Centro. s. c. España
  • Zuil Escobar, JC; Universidad CEU-San Pablo. Facultad de Medicina. Departamento de Fisioterapia. Madrid. España
Fisioterapia (Madr., Ed. impr.) ; 34(2): 73-78, mar.-abr. 2012.
Article in Spanish | IBECS | ID: ibc-111225
Responsible library: ES1.1
Localization: BNCS
RESUMEN
Objetivo El objetivo del presente estudio ha sido evaluar la fiabilidad intrasesión e intersesión, así como la correlación entre las medidas de flexión y extensión de rodilla realizadas mediante goniómetro e inclinómetro. Material y métodos Se ha realizado un estudio de fiabilidad y correlación con una muestra compuesta por 20 sujetos jóvenes y sin patología en el miembro inferior. Se han medido la flexión y la extensión de rodilla, tanto activas como pasivas, empleando goniómetro e inclinómetro. Dichas mediciones se realizaron en tres días distintos, con un margen de una semana entre la primera y la última medición. En cada tiempo de medición se realizaron tres test por medida evaluada. La fiabilidad y la correlación se estudiaron mediante coeficiente de correlación intraclase. Resultados La fiabilidad intrasesión presenta coeficientes de correlación intraclase superiores a 0,89 para los dos instrumentos. En cuanto a la fiabilidad intersesión, los coeficientes de correlación intraclase son superiores a 0,90 en ambos casos. La correlación entre el goniómetro y el inclinómetro presenta valores superiores a 0,812.ConclusionesEl goniómetro y el inclinómetro son instrumentos fiables para la medición de la movilidad articular de la flexión y la extensión de rodilla, presentando, además, una correlación elevada (AU)
ABSTRACT
Aim The aim of the present study was to assess the intra-session and inter-session reliability and correlation between knee flexion and extension measures using a goniometer and an inclinometer. Materials and methods A reliability and correlation study was conducted with a sample of 20 young individuals with no lower limb injuries. Active and passive knee flexion and extension were measured using a goniometer and an inclinometer. Measurements were made during three different days, with one week period between the first and the last session. Three trials were made for each measurement. Reliability and correlation were evaluated using intraclass correlation coefficient. ResultsIntra-session and inter-session reliability showed intraclass correlation coefficients higher than 0.89 and 0.90, respectively, for both instruments. The correlation between the goniometer and inclinometer showed values greater than 0.812.ConclusionsThe goniometer and inclinometer are reliable instruments to evaluate knee range of movement during flexion and extension, as well as showing a high correlation (AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Arthrometry, Articular / Knee / Knee Joint Limits: Humans Language: Spanish Journal: Fisioterapia (Madr., Ed. impr.) Year: 2012 Document type: Article Institution/Affiliation country: Residencia de la Tercera Edad Vital Centro/España / Universidad CEU-San Pablo/España
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Arthrometry, Articular / Knee / Knee Joint Limits: Humans Language: Spanish Journal: Fisioterapia (Madr., Ed. impr.) Year: 2012 Document type: Article Institution/Affiliation country: Residencia de la Tercera Edad Vital Centro/España / Universidad CEU-San Pablo/España
...