Modulación del crecimiento de columnas escolióticas en animales de experimentación mediante el uso de barras de metal inteligente / Modulation of scoliotic spine growth in experimental animals using intelligent metal bars
Rev. esp. cir. ortop. traumatol. (Ed. impr.)
; 57(5): 310-317, sept.-oct. 2013.
Article
in Spanish
| IBECS
| ID: ibc-116039
Responsible library:
ES1.1
Localization: BNCS
RESUMEN
Objetivo. Creación de un modelo experimental de escoliosis estructurada en ratas para evaluar la eficacia de los metales con memoria de forma para corregir gradualmente la deformidad a lo largo del tiempo. Material y método. Se generó una escoliosis experimental en ratas de 3 semanas mediante una sutura entre escápula y pelvis izquierdas durante 8 semanas, tras lo cual fueron aleatorizadas en 2 grupos control, en los que se cortó la sutura, y nitinol, en los que además se implantó un alambre recto con memoria de forma anclado a la columna. Se realizaron radiografías seriadas para determinar la eficacia del nitinol en la corrección de la escoliosis. En un segundo tiempo, evaluamos los cambios histológicos a nivel del cuerpo vertebral apical y discos adyacentes pre y poscorrección. Resultados. Se indujo una cifoescoliosis progresiva media de 81,5°. En el grupo control, tras cortar la sutura, se produjo una reducción inicial de la deformidad pero luego permaneció estable a lo largo del tiempo (54° a las 2 semanas). En el grupo nitinol se observó una reducción progresiva del valor angular de la escoliosis, hasta 8,7° de media a las 2 semanas. El acuñamiento del cuerpo vertebral apical y de los discos adyacentes se corregía parcialmente tras 2 semanas de corrección de la deformidad. Conclusión. En este modelo de escoliosis, un alambre recto de nitinol anclado a la columna ha demostrado eficacia para la corrección gradual de la cifoescoliosis, y de los cambios estructurales asociados a la misma (AU)
ABSTRACT
Objective:
To create an experimental structural scoliosis model in mice to evaluate the efficacy of shape-memory metals to gradually correct the deformity over time. Material andmethod:
Experimental scoliosis was generated in 3 week-old mice by means of a suture between the left scapula and pelvis for 8 weeks. They were then randomised into two groups a control group, in which the suture was cut, and another, in those that also had a Nitinol straight memory-wire implant fixed to the column. Serial X-rays were performed to determine the efficacy of the Nitinol in the correction of the scoliosis. In a second time, the histological changes at apical vertical body level and the adjacent discs were evaluated preand post-correction.Results:
A mean 81.5◦ kyphoscoliosis was gradually induced. In the control group, after cutting the suture, an initial reduction in the deformity was observed, but later it remained stable throughout the time (54◦ at two weeks). In the Nitinol group, a gradual reduction was observed in the scoliosis angle value, to a mean of 8.7◦ at two weeks. The curvature of the apical vertebral body and adjacent discs were partially corrected after two weeks of correcting the deformity.Conclusion:
This scoliosis model has demonstrated the efficacy of a straight Nitinol wire fixed to the spinal column in the gradual correction of kyphoscoliosis and in the changes in its adjacent structures (AU)
Search on Google
Collection:
National databases
/
Spain
Database:
IBECS
Main subject:
Scoliosis
/
Chlorhexidine
/
Antibiotic Prophylaxis
/
Models, Animal
/
Lordosis
Type of study:
Prognostic study
Limits:
Animals
Language:
Spanish
Journal:
Rev. esp. cir. ortop. traumatol. (Ed. impr.)
Year:
2013
Document type:
Article
Institution/Affiliation country:
Hospital Universitario La Paz/España