Diferencias entre la planificación del tratamiento endovascular de aneurismas de aorta abdominal con reconstrucción tridimensional vs tomografía computarizada y angiografía, y su impacto clínico / Differences between endovascular abdominal aortic aneurysm repair planning using three-dimensional reconstruction versus computed tomography and angiography
Angiología
; 66(4): 183-189, jul.-ago. 2014. tab, ilus
Article
in Spanish
| IBECS
| ID: ibc-125221
Responsible library:
ES1.1
Localization: BNCS
RESUMEN
OBJETIVO:
El objetivo es comparar la planificación del tratamiento endovascular de aneurismas de aorta abdominal (endovascular aneurysm repair [EVAR]) realizada mediante estudio tridimensional con la basada en tomografía computarizada (TC) y aortografía centimetrada. Analizar el impacto de la variabilidad de las mediciones en los resultados. MATERIAL YMÉTODOS:
Análisis retrospectivo de 35 casos de EVAR tratados entre 2006-2008 con información completa disponible (mediciones realizadas con TC y aortografía centimetrada). Se comparan dichas mediciones con las realizadas mediante estudio tridimensional (estación de trabajo 3Mensio(R)), mediante 2 modalidades con interpretación diferente línea luminal central pura (CLL) y CLL rectificada (estimando el trayecto de la endoprótesis en la aorta). Se analizó la variabilidad intra e interobservador, y la correlación entre los métodos de medición fue analizada utilizando el coeficiente de correlación intraclase (CCI). Se analizó la influencia de variables anatómicas y las relacionadas con el procedimiento, en la diferencias entre las diferentes técnicas, mediante χ2, test de Fischer y t de Student, considerando un valor de p < 0,05 estadísticamente significativo.RESULTADOS:
Se obtuvo elevada correlación entre las diferentes técnicas de medición, cercana a 0,9 para diámetros, y con CCI de 0,83, 0,75 y 0,76 para L1, L2 y L3, respectivamente (L1 longitud en milímetros desde el cuello aórtico a la bifurcación ilíaca, L2 y L3 longitud en milímetros del cuello aórtico a la zona de sellado en iliaca derecha e izquierda). La correlación intra e interobservador fue superior a 0,8 en todas las mediciones. El diámetro del aneurisma, la tortuosidad de las iliacas y la angulación del cuello influyeron en una mayor variabilidad (p < 0,05). El implante varió respecto al planificado (15%) y se registró una mayor duración de la intervención y tiempo de fluoroscopia en el grupo con variabilidad en medidas L2 y L3 (p < 0,05).CONCLUSIONES:
Aunque el método clásico se ha mostrado eficaz, y los resultados obtenidos con ambas técnicas de medida son comparables, en nuestra experiencia la reconstrucción tridimensional ofrece una mayor precisión en la planificación y aporta beneficios clínicos, sobre todo mediante el uso apropiado de las diferentes técnicas de medida en función de las características anatómicas del aneurismaABSTRACT
OBJECTIVES:
The primary endpoint of this study is to compare endovascular aneurysm repair (EVAR) planning using a three-dimensional study with the one based on computed axial tomography and calibrated aortography. The impact of the variability in the measurements on the clinical and technical outcomes was also analyzed. MATERIAL ANDMETHODS:
Retrospective and observational study of 35 EVAR procedures between the years 2006-2008. Measurements made with CT and calibrated aortography were collected and then compared with measurements made in a three-dimensional study. The CT studies were processed at a workstation using two techniques with two different interpretations pure central lumen line (CLL) and rectified CLL (estimating the path of the graft in the aorta). The correlation between the lengths and diameters were assessed. Intra- and inter-observer agreement and variability between measurement methods were analyzed using the intraclass correlation coefficient (ICC). The anatomical and technical variables associated with differences were also analyzed. χ2, Fischer, and Student-t tests were used for statistical analysis, considering P < 0.05as statistically significant.RESULTS:
The correlation between different measurement techniques was high, close to 0.9 ICC for diameters; and 0.83, 0.75 and 0.76 for L1, L2, and L3, respectively (L1 length in millimeters from the aortic neck to the iliac bifurcation; L2 and L3 length in millimeters from the aortic neck to the right and left iliac bifurcation). The intra- and inter-observer agreement was higher than 0.8 in all measurements. The aneurysm diameter, the tortuosity of the iliac vessels and aortic neck angulation, were associated with greater variability (P < .05). There was a longer surgery and fluoroscopy time, and a need for more limb extensions, and modifications of planned graft in the group with variability in length measurements.CONCLUSIONS:
In our experience the classical method is effective, and the results obtained with both measurement techniques are comparable. Additionally, the three-dimensional study provides greater accuracy in planning, gives more knowledge of the anatomical characteristics of the aneurysm, and provides clinical and technical benefits
Full text:
Available
Collection:
National databases
/
Spain
Database:
IBECS
Main subject:
Aortic Aneurysm, Abdominal
/
Angioplasty, Balloon
/
Endovascular Procedures
Type of study:
Observational study
/
Risk factors
Limits:
Humans
Language:
Spanish
Journal:
Angiología
Year:
2014
Document type:
Article
Institution/Affiliation country: