Your browser doesn't support javascript.
loading
Registro Español de Marcapasos. XI Informe Oficial de la Sección de Estimulación Cardiaca de la Sociedad Española de Cardiología (2013) / Spanish Pacemaker Registry. Eleventh Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2013)
Coma Samartín, Raúl; Cano Pérez, Óscar; Pombo Jiménez, Marta.
Affiliation
  • Coma Samartín, Raúl; Hospital Universitario 12 de Octubre. Madrid. España
  • Cano Pérez, Óscar; Hospital Universitari i Politècnic La Fe. Valencia. España
  • Pombo Jiménez, Marta; Hospital Costal de Sol. Marbella. España
Rev. esp. cardiol. (Ed. impr.) ; 67(12): 1024-1038, dic. 2014. tab, ilus
Article in Spanish | IBECS | ID: ibc-130170
Responsible library: ES1.1
Localization: BNCS
RESUMEN
Introducción y objetivos. Se describe el resultado del análisis de los implantes y recambios de marcapasos remitidos al Registro Español de Marcapasos en 2013, con especial referencia a selección de los modos de estimulación. Métodos. Se basa en el procesado de la información que aporta la Tarjeta Europea del Paciente Portador de Marcapasos. Resultados. Se recibió información de 118 centros hospitalarios, con un total de 12.831 tarjetas, el 35% de la actividad estimada. El consumo de generadores convencionales y dispositivos de resincronización fue de 755 y 58,1 unidades por millón de habitantes respectivamente. La media de edad de los pacientes que recibieron un implante era 77,4 años. El 59,5% de los implantes y el 56,6% de los recambios se realizaron en varones. La mayoría de los implantes y recambios de generadores se produjeron en la franja de los 80 años. Los cables endocavitarios utilizados son bipolares, el 78,7% con sistema de fijación activa. Se estimula en modo VVI/R pese a estar en ritmo sinusal al 24% de los pacientes con enfermedad del nódulo sinusal y el 25% de aquellos con bloqueo auriculoventricular. Conclusiones. Persiste la tendencia a aumentar del consumo de generadores marcapasos y dispositivos de resincronización por millón de habitantes. El sistema de fijación activa de los cables es mayoritario y un 20%, específico de protección de resonancia magnética. La edad y, en menor grado, el tipo de bloqueo auriculoventricular y el sexo son los factores que influyen en la adecuación del modo de estimulación. La monitorización domiciliaria de marcapasos aún dista mucho de generalizarse (AU)
ABSTRACT
Introduction and objectives. The present report summarizes the analysis of pacemaker implantation and replacement data sent to the Spanish Pacemaker Registry in 2013, with specific discussion of pacing mode selection. Methods. This study was based on information obtained from the European Pacemaker Patient Identification Card. Results. Information was received on 118 hospital centers, with a total of 12 831 cards, or 35% of the estimated activity. There were 755 and 58.1 conventional and resynchronization devices per million population, respectively. The mean age of patients receiving an implant was 77.4 years. Men received 59.5% of first implantations and 56.6% of replacements. Most implantations and generator replacements were performed in patients older than 80 years. Almost all endocardial leads used were bipolar, and 78.7% of leads had an active fixation mechanism. Despite being in sinus rhythm, 24% of patients with sick sinus syndrome and 25% of those with atrioventricular block were paced in VVIR mode. Conclusions. The use of pacemaker generators and resynchronization devices per million population continues to increase in Spain. Active fixation mechanisms predominate for leads but just 20% of leads are compatible with magnetic resonance imaging. The factors influencing the correct selection of pacing mode were age and, to a lesser extent, the type of atrioventricular block, and sex. Implementation of home monitoring of pacemakers remains low (AU)
Subject(s)

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Pacemaker, Artificial / Societies, Medical / Bradycardia / Cardiac Pacing, Artificial Type of study: Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2014 Document type: Article Institution/Affiliation country: Hospital Costal de Sol/España / Hospital Universitari i Politècnic La Fe/España / Hospital Universitario 12 de Octubre/España

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Pacemaker, Artificial / Societies, Medical / Bradycardia / Cardiac Pacing, Artificial Type of study: Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2014 Document type: Article Institution/Affiliation country: Hospital Costal de Sol/España / Hospital Universitari i Politècnic La Fe/España / Hospital Universitario 12 de Octubre/España
...