Your browser doesn't support javascript.
loading
Estudio prospectivo aleatorizado sobre la influencia del bloqueo distal del clavo Gamma 3 en el tratamiento de las fracturas pertrocantéreas de fémur / Randomized prospective study on the influence distal block and Gamma 3 nail on the treatment of intertrochanteric fractures of femur
López-Vega, M; Gil-Monzó, E. R; Rodrigo-Pérez, J. L; López-Valenciano, J; Salanova-Paris, R. H; Peralta-Nieto, J; Morales-Suárez, M. M.
Affiliation
  • López-Vega, M; Hospital Universitario Doctor Peset. Valencia. España
  • Gil-Monzó, E. R; Hospital Universitario Doctor Peset. Valencia. España
  • Rodrigo-Pérez, J. L; Universidad de Valencia. Hospital Universitario Doctor Peset. Valencia. España
  • López-Valenciano, J; Hospital de Manises. Manises. España
  • Salanova-Paris, R. H; Hospital Universitario Doctor Peset. Valencia. España
  • Peralta-Nieto, J; Hospital Universitario Doctor Peset. Valencia. España
  • Morales-Suárez, M. M; Universidad de Valencia. Valencia. España
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 59(1): 26-35, ene.-feb. 2015. tab, ilus
Article in Spanish | IBECS | ID: ibc-132375
Responsible library: ES1.1
Localization: BNCS
RESUMEN
Objetivo. El propósito de este estudio es valorar la necesidad de bloquear distalmente los clavos Gamma 3 (Stryker. Mahwah, New Jersey. USA) en fracturas pertrocantéreas de fémur 31-A1 y 31-A2 de la AO. Material y métodos. Desde junio de 2011 hasta enero de 2013 se recoge una muestra formada por 177 pacientes con fractura pertrocantérea de fémur tratados en nuestro centro mediante osteosíntesis con clavo Gamma 3 estándar. Es un estudio prospectivo y aleatorizado según el año de nacimiento de cada paciente, par con bloqueo o impar sin bloqueo distal del clavo, formando dos grupos de 90 y 87 fracturas respectivamente. Resultados. En los pacientes intervenidos mediante clavo con bloqueo distal se observó una mayor incidencia de complicaciones médicas, una menor incidencia de complicaciones biomecánicas y un aumento en el colapso del foco de fractura en comparación con el grupo control, siendo estas diferencias estadísticamente significativas (p < 0,05). También se observa en el grupo con bloqueo distal un mayor requerimiento transfusional y una mayor tasa de éxitus presentando diferencias estadísticamente significativas (p < 0,05), sin embargo esta significación desaparece al ajustar los resultados por otras características relacionadas con los pacientes. Conclusiones. Basándonos en los resultados hallados en este trabajo, el uso del tornillo de bloqueo distal en los clavos Gamma 3 debe restringirse a fracturas pertrocantéreas inestables tras reducción donde se requiera una estabilidad adicional al clavo intramedular, pudiendo así disminuir el riesgo de complicaciones derivadas de su uso (AU)
ABSTRACT
Objective. The purpose of this study is to assess the need to lock the Gamma 3 nail (Stryker, Mahwah New Jersey USA) distally for intertrochanteric fractures of femur 31-A1 and 31-A2 of the AO. Material and methods. Details were recorded on a sample of 177 patients with intertrochanteric femoral fractures treated in our hospital by a standard Gamma nail between June 2011 and January 2013. A prospective study was conducted by randomizing patients by year of birth, even numbers with, or odd number without, distal locking, forming two groups of 90 and 87 fractures, respectively. Results. The patients treated with a distal locking nail had an increased incidence of medical complications, a lower incidence of biomechanical complications, and an increase in the fracture collapse compared with the control group, with statistical significance (p < 0 .05). It is also observed in the group with distal locking increased transfusion requirement and a higher death rate, with statistically significant differences (p < 0 .05), but this significance disappears when adjusting for other patient-related characteristics. Conclusions. Based on the results found in this work, the use of distal locking screw in the Gamma 3 nails should be restricted to unstable trochanteric fractures after reduction where additional stability to the intramedullary nail is required, and may decrease the risk of complications from use (AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Bone Nails / Orthopedic Procedures / Fracture Fixation, Internal / Hip Fractures Type of study: Controlled clinical trial / Etiology study / Incidence study / Observational study / Risk factors Limits: Aged / Female / Humans / Male Language: Spanish Journal: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Year: 2015 Document type: Article Institution/Affiliation country: Hospital Universitario Doctor Peset/España / Hospital de Manises/España / Universidad de Valencia/España
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Bone Nails / Orthopedic Procedures / Fracture Fixation, Internal / Hip Fractures Type of study: Controlled clinical trial / Etiology study / Incidence study / Observational study / Risk factors Limits: Aged / Female / Humans / Male Language: Spanish Journal: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Year: 2015 Document type: Article Institution/Affiliation country: Hospital Universitario Doctor Peset/España / Hospital de Manises/España / Universidad de Valencia/España
...