Your browser doesn't support javascript.
loading
Efectividad y predictores de fracaso de la ventilación mecánica no invasiva en la insuficiencia respiratoria aguda / Effectiveness and predictors of failure of noninvasive mechanical ventilation in acute respiratory failure
Martín-González, F; González-Robledo, J; Sánchez-Hernández, F; Moreno-García, MN; Barreda-Mellado, I.
Affiliation
  • Martín-González, F; Hospital Universitario de Salamanca. Unidad de Cuidados Intensivos. Salamanca. España
  • González-Robledo, J; Hospital Universitario de Salamanca. Unidad de Cuidados Intensivos. Salamanca. España
  • Sánchez-Hernández, F; Universidad de Salamanca. Escuela de Enfermería y Fisioterapia. Salamanca. España
  • Moreno-García, MN; Universidad de Salamanca. Departamento de Informática y Automática. Salamanca. España
  • Barreda-Mellado, I; Universidad de Salamanca. Departamento de Estadística. Salamanca. España
Med. intensiva (Madr., Ed. impr.) ; 40(1): 9-17, ene.-feb. 2016. tab, graf
Article in Spanish | IBECS | ID: ibc-149335
Responsible library: ES1.1
Localization: BNCS
RESUMEN

OBJETIVO:

Evaluar la efectividad e identificar predictores de fracaso de la ventilación mecánica no invasiva en la insuficiencia respiratoria aguda.

DISEÑO:

Estudio retrospectivo, longitudinal y descriptivo. ÁMBITO Pacientes adultos con insuficiencia respiratoria aguda. PACIENTES Un total de 410 pacientes (muestra consecutiva) tratados mediante ventilación mecánica no invasiva en una unidad de cuidados intensivos de un hospital universitario terciario entre 2006 y 2011. INTERVENCIONES Ventilación mecánica no invasiva. VARIABLES PRINCIPALES DE INTERÉS Variables demográficas, clínicas y analíticas desde el inicio de la ventilación mecánica no invasiva y 2h después. Variables evolutivas durante el ingreso en la unidad y hasta el alta hospitalaria.

RESULTADOS:

El fracaso fue del 50%, y la mortalidad global del 33%. Un total de 156 pacientes presentaban insuficiencia respiratoria aguda hipoxémica, 87 insuficiencia respiratoria postextubación, 78 reagudización de enfermedad pulmonar obstructiva crónica, 61 insuficiencia respiratoria hipercápnica sin enfermedad pulmonar obstructiva crónica y 28 edema pulmonar agudo cardiogénico. El fracaso fue del 74, del 54, del 27, del 31 y del 21%, respectivamente. El tipo de insuficiencia respiratoria, la bilirrubina sérica al inicio, APACHEII, la existencia de hallazgos radiológicos, la necesidad de sedación para tolerarla y los cambios en el nivel de consciencia, ratio PaO2/FiO2, frecuencia respiratoria y frecuencia cardiaca entre el inicio y 2 h después se asociaron con el fracaso.

CONCLUSIONES:

La efectividad de la técnica varió dependiendo del tipo de insuficiencia respiratoria. Su uso en la insuficiencia respiratoria aguda hipoxémica y la insuficiencia respiratoria postextubación debería valorarse individualmente. Los predictores de fracaso podrían ser útiles para prevenir el retraso en la intubación orotraqueal
ABSTRACT

OBJECTIVE:

To assess the effectiveness and identify predictors of failure of noninvasive ventilation.

DESIGN:

A retrospective, longitudinal descriptive study was made.

SETTING:

Adult patients with acute respiratory failure. PATIENTS A total of 410 consecutive patients with noninvasive ventilation treated in an Intensive Care Unit of a tertiary university hospital from 2006 to 2011. PROCEDURES Noninvasive ventilation. MAIN VARIABLES OF INTEREST Demographic variables and clinical and laboratory test parameters at the start and two hours after the start of noninvasive ventilation. Evolution during admission to the Unit and until hospital discharge.

RESULTS:

The failure rate was 50%, with an overall mortality rate of 33%. A total of 156 patients had hypoxemic respiratory failure, 87 postextubation respiratory failure, 78 exacerbation of chronic obstructive pulmonary disease, 61 hypercapnic respiratory failure without chronic obstructive pulmonary disease, and 28 had acute pulmonary edema. The failure rates were 74%, 54%, 27%, 31% and 21%, respectively. The etiology of respiratory failure, serum bilirubin at the start, APACHEII score, radiological findings, the need for sedation to tolerate noninvasive ventilation, changes in level of consciousness, PaO2/FIO2 ratio, respiratory rate and heart rate from the start and two hours after the start of noninvasive ventilation were independently associated to failure.

CONCLUSIONS:

The effectiveness of noninvasive ventilation varies according to the etiology of respiratory failure. Its use in hypoxemic respiratory failure and postextubation respiratory failure should be assessed individually. Predictors of failure could be useful to prevent delayed intubation
Subject(s)

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Respiratory Insufficiency / Ventilator Weaning / Noninvasive Ventilation Type of study: Etiology study / Evaluation study / Observational study / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Med. intensiva (Madr., Ed. impr.) Year: 2016 Document type: Article Institution/Affiliation country: Hospital Universitario de Salamanca/España / Universidad de Salamanca/España

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Respiratory Insufficiency / Ventilator Weaning / Noninvasive Ventilation Type of study: Etiology study / Evaluation study / Observational study / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Med. intensiva (Madr., Ed. impr.) Year: 2016 Document type: Article Institution/Affiliation country: Hospital Universitario de Salamanca/España / Universidad de Salamanca/España
...