Aplicación del test electrofisiológico de ejercicio en pacientes con miotonía congénita / Application of electrophysiological exercise test in patients with congenital myotonia
Acta pediatr. esp
; 74(2): 50-56, feb. 2016. ilus, tab, graf
Article
in Spanish
| IBECS
| ID: ibc-150593
Responsible library:
ES1.1
Localization: BNCS
RESUMEN
Introducción:
La miotonía congénita (MC) es la canalopatía muscular más frecuente, con una prevalencia que varía, según la región, entre 0,2 y 7,3 por cada 100.000 habitantes. Se debe a mutaciones en el gen CLCN1, localizado en el cromosoma 7q35, que codifica para la proteína CIC-1, y se caracteriza por presentar miotonía clínica y cambios electrofisiológicos en el potencial de acción muscular compuesto (PAMC), evidentes con el test de ejercicio. El objetivo de este estudio es describir los cambios electrofisiológicos de estos pacientes a partir del test electrofisiológico de ejercicio. Material ymétodos:
Estudio longitudinal y prospectivo. Se aplicó el test electrofisiológico de ejercicio largo y corto, descrito por Fournier y Streib, incluyendo una exploración con electrodo de aguja, a 5 pacientes con diagnóstico clínico previo de MC, 4 (80%) hombres y 1 (20%) mujer, con una media de edad de 22,17 años, previa estandarización del procedimiento con 10 controles sanos.Resultados:
En los 5 pacientes se asoció, en función del decremento significativo en la amplitud del PAMC en el test corto, un patrón de MC, es decir, el patrón electrofisiológico II (de los cinco descritos por Fournier).Conclusiones:
El estudio electrodiagnóstico confirmó en todos los casos los hallazgos clínicos de MC. A pesar de que el estudio genético confirma la mutación, considerándose el estándar de referencia diagnóstico, el test de ejercicio continúa siendo una herramienta útil para el diagnóstico, dada la escasa accesibilidad del estudio genético en nuestro medio (AU)ABSTRACT
Introduction:
Congenital myotonia (CM) is the most common muscular channelopathy with prevalence varies according to the region between 0.2 and 7.3 per 100,000 inhabitants is due to mutations in the CLCN1 gene located in the 7q35 chromosome coding for the CIC-1 protein manifested by clinical myotonia present and electrophysiological changes in the compound muscle action potential (CMAP) evident with exercise test. The objective of this study is to describe the electrophysiological changes of these patients from electrophysiological exercise test.Methods:
longitudinal prospective study. Electrophysiological test of long and short exercise described by Fournier and Streib, including scanning electrode needle in 5 patients with previous clinical diagnosis of CM, 4 (80%) men and 1 (20%) women, with a median age is applied 22.17 years, after standardization of the procedure with 10 healthy controls.Results:
In 5 patients, was associated, based on the significant decrease in the CMAP amplitude in the short test, a pattern of MC, ie electrophysiological Pattern II (the five described by Fournier).Conclusions:
The study confirmed electrodiagnosis in all cases the clinical findings of CM, and although genetic mutation study confirms considered the diagnostic gold standard, the test exercise continues to be a useful diagnostic tool, given the lack of accessibility genetic studies in our environment (AU)
Full text:
Available
Collection:
National databases
/
Spain
Database:
IBECS
Main subject:
Electrodiagnosis
/
Electrophysiology
/
Myotonia Congenita
Type of study:
Evaluation study
/
Observational study
/
Risk factors
Limits:
Child
/
Humans
Language:
Spanish
Journal:
Acta pediatr. esp
Year:
2016
Document type:
Article
Institution/Affiliation country:
CRIT Guerrero/México
/
Clínica del CRIT Guerrero/México
/
Instituto Nacional de Rehabilitación/México