Análisis in vitro de la resistencia a la fractura de estructuras de fibra de carbono termocicladas / In vitro resistance to fracture testing of carbon fiber structures after thermal cycling
Cient. dent. (Ed. impr.)
; 13(2): 155-160, mayo-ago. 2016. ilus, tab
Article
in Spanish
| IBECS
| ID: ibc-155291
Responsible library:
ES1.1
Localization: BNCS
RESUMEN
Objetivos:
Comparar la resistencia a la fractura de estructuras de fibra de carbono con estructuras de cobalto-cromo, unidas a resina y tras termociclado. Materiales ymétodos:
se confeccionaron cinco probetas de fibra de carbono y cinco de cromo-cobalto y se unieron a resina acrílica. Ambas probetas se sometieron a 5000 ciclos de termociclado, permaneciendo durante 30 segundos en saliva artificial entre 5º y 55º C de temperatura entre cada ciclo. Posteriormente se realizó un ensayo por carga en tres puntos hasta producirse fractura de las probetas.Resultados:
Dos de las cinco probetas de fibra de carbono presentaron separación de los materiales tras el termociclado. El grupo de fibra de carbono obtuvo valores más bajos en la resistencia a la fractura (305,6 N), mientras que el grupo de cromo-cobalto alcanzó los 664,8 N de media (p=0,008).Conclusiones:
Dentro de los límites del estudio, la resistencia a la fractura de las probetas de fibra de carbono fue significativamente menor que la de las probetas de cromo-cobalto. Es necesario mejorar las estructuras para poder indicar este material como alternativa al cromo-cobalto en prótesis híbridas implantosoportadas (AU)ABSTRACT
Objective:
To compare the resistance to fracture of carbon fiber and acrylic resin structures and with cobalt-chromium alloy and acrilic resin structures after thermal cycling. Material andmethods:
Five carbon fiber reinforced acrylic resin and five cobalt-chromium alloy embebed in acrylic resin specimens were fabricated. All specimens were thermal cycled from 5º to 55ºC for 5000 cycles with a 30-s dwell time. A three point loading test until fracture of specimens was performed.Results:
In two of five specimens separation of carbon fiber from acrylic resin was observed after thermal cycling. The carbon fiber reinforced group presented lower resistance values (305,6 N) while cobalt-chromium group reached an average of 664,8 N (p=0.008).Conclusions:
Within the limitations of this study, the resistance to fracture of carbon fiber specimens were significantly lower than cobalt-chormium group. More studies and improvment of carbon fiber reinforced resins are necessary in order to be used as alternative material for implant-supported hybrid prosthesis (AU)
Full text:
Available
Collection:
National databases
/
Spain
Database:
IBECS
Main subject:
Carbon
/
Dental Materials
/
51660
Limits:
Humans
Language:
Spanish
Journal:
Cient. dent. (Ed. impr.)
Year:
2016
Document type:
Article
Institution/Affiliation country:
Universidad Rey Juan Carlos/España
/
Università Complutense di Madrid/España