Ablación con catéter no guiada por fluoroscopia. Resultados de un registro prospectivo multicéntrico / Nonfluoroscopic catheter ablation. results from a prospective multicenter registry
Álvarez, Miguel; Bertomeu-González, Vicente; Arcocha, M Fe; Moriña, Pablo; Tercedor, Luis; Ferrero de Loma, Ángel; Pachón, Marta; García, Amaya; Pardo, Mónica; Datino, Tomás; Alonso, Concepción; Osca, Joaquín.
Affiliation
  • Álvarez, Miguel; Complejo Hospitalario Universitario de Granada. Departamento de Cardiología. Granada. España
  • Bertomeu-González, Vicente; Hospital Universitario San Juan de Alicante. Departamento de Cardiología. San Juan de Alicante. España
  • Arcocha, M Fe; Hospital de Basurto. Departamento de Cardiología. Bilbao. España
  • Moriña, Pablo; Hospital Juan Ramón Jiménez. Departamento de Cardiología. Huelva. España
  • Tercedor, Luis; Complejo Hospitalario Universitario de Granada. Departamento de Cardiología. Granada. España
  • Ferrero de Loma, Ángel; Hospital Clínico de Valencia. Departamento de Cardiología. Valencia. España
  • Pachón, Marta; Hospital Virgen de la Salud. Departamento de Cardiología. Toledo. España
  • García, Amaya; Hospital General de Alicante. Departamento de Cardiología. Alicante. España
  • Pardo, Mónica; Hospital do Meixoeiro. Departamento de Cardiología. Vigo. España
  • Datino, Tomás; Hospital General Universitario Gregorio Marañón. Departamento de Cardiología. Madrid. España
  • Alonso, Concepción; Hospital de la Santa Creu i Sant Pau. Departamento de Cardiología. Barcelona. España
  • Osca, Joaquín; Hospital La Fe. Departamento de Cardiología. Valencia. España
Rev. esp. cardiol. (Ed. impr.) ; 70(9): 699-705, sept. 2017. graf, tab
Article in Spanish | IBECS | ID: ibc-166496
Responsible library: ES1.1
Localization: BNCS
RESUMEN
Introducción y

objetivos:

La ablación con catéter sin guía fluoroscópica es factible en la mayoría de los casos. El objetivo de nuestro registro es evaluar la factibilidad y la seguridad de la ablación no guiada por fluoroscopia en varios centros españoles.

Métodos:

Once hospitales incluyeron prospectivamente a, al menos, 20 pacientes afectados de un sustrato arrítmico cuyo procedimiento de ablación, a juicio de cada operador, se podía abordar sin fluoroscopia durante todo el procedimiento. No se incluyó a pacientes portadores de dispositivos intracardiacos. Electrofisiólogos de plantilla, becarios y residentes participaron en cada procedimiento de forma habitual.

Resultados:

Se incluyó a un total de 247 pacientes (n = 247). Se realizó ablación en 235 casos (95,2%), y en 2 casos que no se incluyeron en el análisis la fluoroscopia se utilizó como primera intención. En el 99,15% (231/233) de los procedimientos analizados el sustrato arrítmico abordado se localizaba en cavidades derechas. Se requirió fluoroscopia en 24 (10,3%), se obtuvo éxito en el 96,4% de los procedimientos y hubo complicaciones graves en 2 pacientes (0,85%). Las variables relacionadas con la necesidad de fluoroscopia fueron el centro realizador (máximo, 33,3%; mínimo, 0; p = 0,001) y el fracaso del procedimiento (el 13 frente al 2,4%; p < 0,05).

Conclusiones:

El registro multicéntrico muestra que la ablación sin escopia de sustratos localizados en cavidades derechas es factible en la mayoría de los procedimientos. Se necesitan estudios aleatorizados para confirmar su seguridad. La necesidad de fluoroscopia es mayor en los procedimientos sin éxito y es variable en los centros realizadores (AU)
ABSTRACT
Introduction and

objectives:

Nonfluoroscopic catheter ablation is feasible in most procedures. The aim of our registry was to evaluate the safety and feasibility of a zero-fluoroscopic approach to catheter ablation in several Spanish centers.

Methods:

Eleven centers prospectively included a minimum of 20 patients. Patients with an arrhythmic substrate deemed suitable by the operator for a zero-fluoroscopic approach throughout the procedure were recruited. Patients with intracardiac devices were not included. Attending electrophysiologists, fellows, and resident physicians participated in each procedure, as in usual care.

Results:

The study included 247 patients. Ablation was performed in 235 patients (95.2%). In 2 patients, who were not included in the analysis, fluoroscopy was performed as the first-line treatment. The arrhythmic substrate was located in the right chambers in most of the procedures (231 of 233 [99.15%]). Fluoroscopy was used in 24 procedures (10.3%). Catheter ablation was successful in 96.4% of the procedures and severe complications occurred in 2 patients (0.85%). Two variables were related to the need for fluoroscopy the performing center (minimum 0% vs maximum 30.3%; P = .001) and procedural failure (13% vs 2.4%; P < .05).

Conclusions:

The Spanish multicenter registry reveals that a zero-fluoroscopic approach is feasible in most right-sided catheter ablation procedures. Randomized trials are necessary to confirm the safety of this approach. The need for fluoroscopy was related to procedural failure, with significant differences among performing centers (AU)
Subject(s)

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Arrhythmias, Cardiac / Catheter Ablation Type of study: Controlled clinical trial / Practice guideline Limits: Humans Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2017 Document type: Article Institution/Affiliation country: Complejo Hospitalario Universitario de Granada/España / Hospital Clínico de Valencia/España / Hospital General Universitario Gregorio Marañón/España / Hospital General de Alicante/España / Hospital Juan Ramón Jiménez/España / Hospital La Fe/España / Hospital Universitario San Juan de Alicante/España / Hospital Virgen de la Salud/España / Hospital de Basurto/España / Hospital de la Santa Creu i Sant Pau/España

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Arrhythmias, Cardiac / Catheter Ablation Type of study: Controlled clinical trial / Practice guideline Limits: Humans Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2017 Document type: Article Institution/Affiliation country: Complejo Hospitalario Universitario de Granada/España / Hospital Clínico de Valencia/España / Hospital General Universitario Gregorio Marañón/España / Hospital General de Alicante/España / Hospital Juan Ramón Jiménez/España / Hospital La Fe/España / Hospital Universitario San Juan de Alicante/España / Hospital Virgen de la Salud/España / Hospital de Basurto/España / Hospital de la Santa Creu i Sant Pau/España
...