Your browser doesn't support javascript.
loading
Inserción de prótesis metálicas autoexpandibles totalmente recubiertas en patología biliar benigna / Insertion of fully covered self-expanding metal stents in benign biliary diseases
Omodeo, Mariana; Malaga, Ignacio; Manazzoni, Dante; Curvale, Cecilia; Maria, Julio de; Guidi, Martín; Matano, Raúl.
Affiliation
  • Omodeo, Mariana; Hospital El Cruce Dr. Néstor Carlos Kirchner. Servicio de Gastroenterología y Endoscopia. Florencio Varela. Argentina
  • Malaga, Ignacio; Hospital El Cruce Dr. Néstor Carlos Kirchner. Servicio de Gastroenterología y Endoscopia. Florencio Varela. Argentina
  • Manazzoni, Dante; Hospital El Cruce Dr. Néstor Carlos Kirchner. Servicio de Gastroenterología y Endoscopia. Florencio Varela. Argentina
  • Curvale, Cecilia; Hospital El Cruce Dr. Néstor Carlos Kirchner. Servicio de Gastroenterología y Endoscopia. Florencio Varela. Argentina
  • Maria, Julio de; Hospital El Cruce Dr. Néstor Carlos Kirchner. Servicio de Gastroenterología y Endoscopia. Florencio Varela. Argentina
  • Guidi, Martín; Hospital El Cruce Dr. Néstor Carlos Kirchner. Servicio de Gastroenterología y Endoscopia. Florencio Varela. Argentina
  • Matano, Raúl; Hospital El Cruce Dr. Néstor Carlos Kirchner. Servicio de Gastroenterología y Endoscopia. Florencio Varela. Argentina
Rev. esp. enferm. dig ; 110(1): 30-34, ene. 2018. ilus, tab
Article in Spanish | IBECS | ID: ibc-170051
Responsible library: ES1.1
Localization: BNCS
RESUMEN

Introducción:

las enfermedades biliares benignas se han tratado, tradicionalmente, mediante la colocación de prótesis plásticas. Sin embargo, en la actualidad, las prótesis metálicas autoexpandibles totalmente recubiertas están ganando aceptación para el tratamiento de dichas patologías.

Objetivo:

evaluar la eficacia y las complicaciones de la inserción endoscópica temporal de prótesis metálicas totalmente recubiertas para el tratamiento de patologías biliares benignas. Materiales y

métodos:

estudio retrospectivo y observacional realizado a partir de una base de datos prospectiva en un centro de tercer nivel entre marzo de 2012 y mayo de 2016. Se incluyeron pacientes a los que se les colocó una prótesis metálica totalmente recubierta por patología benigna de la vía biliar. Se documentaron las indicaciones, las tasas de resolución, las de éxito técnico y los eventos adversos.

Resultados:

se incluyeron 31 pacientes a los que se insertaron 34 prótesis. Las indicaciones fueron las siguientes 8 (25%) estenosis biliares poscolecistectomía, 11 (31%) coledocolitiasis de gran tamaño o múltiple, 3 (8,3%) fístulas biliares, 2 (6%) estenosis postrasplante hepático, 3 (8,3%) estenosis papilares, 2 (6%) perforaciones y 2 (6%) sangrados. La tasa de éxito global de resolución de la patológica fue del 88% 87,5% (7/8) en estenosis poscolecistectomía, 73% (8/11) en litiasis gigante, y 100% en el resto de las indicaciones. Se retiraron mediante endoscopia 33 de las 34 tras un promedio de 133 días (rango 10-180 días). No se registraron complicaciones.

Conclusión:

las prótesis metálicas autoexpandibles totalmente recubiertas son una alternativa efectiva y segura en la resolución de patologías biliares benignas (AU)
ABSTRACT

Introduction:

Benign biliary diseases are traditionally treated using plastic stents. However, fully covered self-expanding metal stents are currently gaining acceptance for the treatment of these pathologies.

Objective:

To assess the effectiveness and complications associated with the placement of temporary endoscopic fully covered self-expanding metal stents for the treatment of benign biliary diseases. Materials and

methods:

This was a retrospective and observational study using a prospective database from a tertiary care center from March 2012 to May 2016. Some patients that had a fully covered metal stent due to a benign biliary disease were also included. The indications, resolution, technical success rates and adverse events were documented.

Results:

31 patients were included with a total of 34 stents inserted. The indications were as follows 8 (25%) post cholecystectomy biliary stenoses, 11 (31%) large or multiple choledocholithiasis, 3 (8.3%) biliary fistulas, 2 (6%) post-liver transplant stenoses, 2 (8.3%) papillary stenoses, 2 (6%) perforations and 2 (6%) bleeds. The global resolution success rate of the stents for all pathologies was 88%, this included 87.5% (7/8) in post cholecystectomy stenoses, 73% (8/11) in large choledocholithiasis and 100% for the remaining indications. Thirty-three of 34 stents were removed after an average of 133 days (ranging from 10 to 180 days). No complications were registered.

Conclusion:

Fully covered self-expanding metal stents are an effective and reliable alternative for the resolution of benign biliary diseases (AU)
Subject(s)

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Biliary Tract Diseases / Drug-Eluting Stents / Self Expandable Metallic Stents Type of study: Observational study / Risk factors Limits: Adult / Aged / Female / Humans / Male Language: Spanish Journal: Rev. esp. enferm. dig Year: 2018 Document type: Article Institution/Affiliation country: Hospital El Cruce Dr. Néstor Carlos Kirchner/Argentina

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Biliary Tract Diseases / Drug-Eluting Stents / Self Expandable Metallic Stents Type of study: Observational study / Risk factors Limits: Adult / Aged / Female / Humans / Male Language: Spanish Journal: Rev. esp. enferm. dig Year: 2018 Document type: Article Institution/Affiliation country: Hospital El Cruce Dr. Néstor Carlos Kirchner/Argentina
...