Your browser doesn't support javascript.
loading
Calidad de la sedación con propofol administrada por personal no anestesiólogo en una unidad de endoscopia digestiva, resultados tras un año de implantación / Quality of sedation with propofol administered by non-anesthetists in a digestive endoscopy unit: the results of a one year experience
López Muñoz, Cristina; Sánchez Yagüe, Andrés; Canca Sánchez, José Carlos; Reinaldo Lapuerta, José Antonio; Moya Suárez, Ana Belén.
Affiliation
  • López Muñoz, Cristina; Agencia Sanitaria de la Costa del Sol. Unidad de Pruebas Funcionales Digestivas. Marbella. España
  • Sánchez Yagüe, Andrés; Agencia Sanitaria de la Costa del Sol. Departamento de Aparato Digestivo. Marbella. España
  • Canca Sánchez, José Carlos; Agencia Sanitaria de la Costa del Sol. Dirección de Enfermería. Marbella. España
  • Reinaldo Lapuerta, José Antonio; Agencia Sanitaria de la Costa del Sol. Área de Reanimación y Anestesia. Marbella. España
  • Moya Suárez, Ana Belén; Agencia Sanitaria de la Costa del Sol. Unidad de Enfermería de Digestivo. Marbella. España
Rev. esp. enferm. dig ; 110(4): 231-236, abr. 2018. tab
Article in Spanish | IBECS | ID: ibc-174596
Responsible library: ES1.1
Localization: BNCS
RESUMEN

Introducción:

existe evidencia de que un equipo formado por endoscopista y enfermera puede hacerse cargo de la sedación de un paciente con propofol de forma eficaz, segura y eficiente. Para ello, es fundamental una adecuada formación y entrenamiento específico que les otorgue las competencias necesarias. El objetivo principal de este estudio fue realizar, tras un año de implantación, una evaluación de la calidad del procedimiento de sedación administrada por personal no anestesiólogo en una unidad de endoscopia digestiva.

Métodos:

se realizó un estudio de cohortes prospectivo sobre los pacientes que recibieron sedación con propofol por personal no anestesiólogo. Posteriormente, se seleccionó una muestra aleatoria de registros clínicos para evaluar la adherencia de los profesionales a diferentes criterios de calidad, así como la aparición de eventos adversos relacionados con la sedación.

Resultados:

en el periodo de estudio se realizaron un total de 595 procedimientos bajo sedación con propofol. La tasa de eventos adversos fue del 2,4% (n = 507), principalmente episodios de hipotensión e hipoxemia. Los porcentajes de adherencia al procedimiento de sedación se situaron por encima del 80% en la mayoría de los criterios, aunque fue menor en la cumplimentación de la valoración del riesgo ASA.

Conclusión:

los resultados del estudio sugieren que el propofol puede ser administrado con seguridad y eficacia por un equipo cualificado de endoscopista y enfermera, en pacientes con un riesgo ASA I-II. Las auditorías sobre la adherencia de los profesionales al procedimiento permiten identificar necesidades de mejora para poder seguir trabajando sobre aspectos aún no consolidados
ABSTRACT

Introduction:

research has shown that an endoscopist-nurse clinical team can perform sedation with propofol effectively, safely and efficiently. To do so, it is essential to provide specific and appropriate training in the necessary skills. The main aim of the present study was to evaluate the quality of the sedation procedure administered by non-anesthetists in a digestive endoscopy unit, one year after its introduction.

Methods:

a prospective cohort study was performed in patients given propofol sedation by non-anesthetists. Subsequently, a random sample of clinical records was selected in order to evaluate the adherence of professionals to the quality criteria and to assess the rate of adverse events related to sedation.

Results:

a total of 595 procedures were performed under propofol sedation during the study period. The rate of adverse events was 2.4% (n = 507), mainly involving hypotension and hypoxemia. Adherence to the sedation procedure was above 80% for most of the applicable criteria, although it was lower for the completion of ASA risk evaluation.

Conclusions:

the results of the study suggest that propofol can be administered safely and effectively by a qualified endoscopist-nurse team, in patients with an ASA I-II risk. Audits of adherence by medical staff to the recommended procedure facilitate the identification of areas for improvement; further work is needed on the aspects that have not yet been consolidated
Subject(s)

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Propofol / Conscious Sedation / Endoscopy, Gastrointestinal / Hypnotics and Sedatives Type of study: Controlled clinical trial / Etiology study / Incidence study / Observational study / Prognostic study / Risk factors Limits: Adult / Aged / Female / Humans / Male Language: Spanish Journal: Rev. esp. enferm. dig Year: 2018 Document type: Article Institution/Affiliation country: Agencia Sanitaria de la Costa del Sol/España

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Propofol / Conscious Sedation / Endoscopy, Gastrointestinal / Hypnotics and Sedatives Type of study: Controlled clinical trial / Etiology study / Incidence study / Observational study / Prognostic study / Risk factors Limits: Adult / Aged / Female / Humans / Male Language: Spanish Journal: Rev. esp. enferm. dig Year: 2018 Document type: Article Institution/Affiliation country: Agencia Sanitaria de la Costa del Sol/España
...