Detección e identificación de cannabinoides sintéticos en muestras sólidas y biológicas / Detection and identification of synthetic cannabinoids in solid and biological samples
Martínez-Galdámez, ME; Llorente Ballesteros, MT; Urquía Grande, ML; López Colón, JL.
Affiliation
  • Martínez-Galdámez, ME; Instituto de Toxicología de la Defensa. Madrid. España
  • Llorente Ballesteros, MT; Instituto de Toxicología de la Defensa. Madrid. España
  • Urquía Grande, ML; Instituto de Toxicología de la Defensa. Madrid. España
  • López Colón, JL; Instituto de Toxicología de la Defensa. Madrid. España
Sanid. mil ; 75(1): 14-18, ene.-mar. 2019. ilus, graf
Article in Spanish | IBECS | ID: ibc-183700
Responsible library: ES1.1
Localization: BNCS
RESUMEN

Introducción:

Los cannabinoides sintéticos (CBS) son sustancias que imitan los efectos del delta-9-tetrahidrocannabinol (THC). Los CBS no dan positivo en los tests de cribado de drogas habituales, dado que no son detectables por las técnicas de identificación. La cromatografía de gases con espectrometría de masas (GC-MS) es la técnica de referencia para el análisis de los CBS. Presentamos un método de detección y cuantificación de metabolitos de CBS en orina mediante cromatografía líquida acoplada a espectrometría de masas de alta resolución (HPLC-HRMS).

Objetivos:

Identificación de CBS en muestras solidas mediante GC-MS y optimización e implementación de un método para la detección de CBS en orina por HPLC-HRMS. Material y

métodos:

Análisis de 8 muestras sólidas de compuestos herbales y de 30 muestras de orina de consumidores sospechosos de CBS remitidas al ITOXDEF para su identificación y confirmación.

Resultados:

Se han identificado 8 CBS en los 8 compuestos herbales mediante GC-MS y dos CBS (UR-144 y JWH-018) en las muestras de orina.

Conclusiones:

En el Instituto de Toxicología de Defensa se ha puesto en marcha un método analítico para la detección de cannabinoides sintéticos en orina, empleando como técnica analítica instrumental un equipo de cromatografía líquida de alta resolución (HPLC) acoplada a espectrometría de masas de alta resolución (HRMS). Se considera que el método analítico ha sido desarrollado satisfactoriamente, dado que los datos obtenidos en los estudios realizados demuestran que el método es apto para su uso previsto. En el futuro se podrán analizar también los CBS en líquidos biológicos como son pelo y saliva, con las ventajas siguientes disminuye tiempo de análisis, es más sensible y más exacto, y es menos invasivo
ABSTRACT

Introduction:

Synthetic cannabinoids (SC) are substances that mimic the effects of delta-9-tetrahydrocannabinol (THC). SCs do not cause a positive drug test for marijuana or other illegal drugs, since they are not detectable in standard drug tests. Gas chromatography-mass spectrometry (GC-MS) is one of the most commonly used techniques for analysis of synthetic cannabinoids. We present a method for the detection and quantitation of several urinary synthetic cannabinoids metabolites by high-performance liquid chromatography coupled with high resolution mass spectrometry (HPLC-HRMS).

Objectives:

Identification of SC in suspicious solid samples by GC.MS, and optimization and implementation of an analytical method for the detection of SC in urine, using HPLC tandem with HRMS. Material and

methods:

Analysis of solid samples A total of eight samples received were analyzed for identification and confirmation. Urine

analysis:

We analyzed a total of 30 urine samples with possible suspicion of having used synthetic cannabis.

Results:

In the present project, synthetic cannabinoids were identified 8 in 8 herbal incense products by employing GC-MS and 2 were determined in 30 urine samples by HPLC.

Conclusions:

Like all other drugs of abuse, the confirmation analysis is based on GC-MS. We have optimized and implemented an analytical method for the detection of SCs in urine, using a HPLC tandem with HRMS as an analytical technique. The analytical method is believed to have been satisfactorily developed which is proved by the data gathered from the studies carried out proving thus its adequacy to the previewed use. Further research might include the analysis of the CBS in biological liquids (hair, saliva) which presents added advantages such as the reduction of the procedure time, its less invasive character and greater precision
Subject(s)

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Cannabinoids / Urinalysis / Gas Chromatography-Mass Spectrometry Limits: Adolescent / Humans Language: Spanish Journal: Sanid. mil Year: 2019 Document type: Article Institution/Affiliation country: Instituto de Toxicología de la Defensa/España

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Cannabinoids / Urinalysis / Gas Chromatography-Mass Spectrometry Limits: Adolescent / Humans Language: Spanish Journal: Sanid. mil Year: 2019 Document type: Article Institution/Affiliation country: Instituto de Toxicología de la Defensa/España
...