Cambios en la selección e impacto potencial de los inhibidores de neprilisina y del receptor de la angiotensina en los pacientes sometidos a reparación mitral percutánea borde a borde / Temporal trend and potential impact of angiotensin receptor neprilysin inhibitors on transcatheter edge-to-edge mitral valve repair
Barrero, Alejandro; Carrasco-Chinchilla, Fernando; Benito-González, Tomás; Pascual, Isaac; Arzamendi, Dabit; Estévez-Loureiro, Rodrigo; Nombela-Franco, Luis; Pani, Manuel; Freixa, Xavier; Trillo-Nouche, Ramiro.
Affiliation
  • Barrero, Alejandro; Hospital Clínico Universitario de Valladolid. Departamento de Cardiología. Valladolid. España
  • Carrasco-Chinchilla, Fernando; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV). España
  • Benito-González, Tomás; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV). España
  • Pascual, Isaac; Hospital Universitario Central de Asturias. Departamento de Cardiología. Asturias. España
  • Arzamendi, Dabit; Hospital Sant Pau. Departamento de Cardiología. Barcelona. España
  • Estévez-Loureiro, Rodrigo; Hospital Álvaro Cunqueiro. Departamento de Cardiología. Pontevedra. España
  • Nombela-Franco, Luis; Hospital Clínico San Carlos. Departamento de Cardiología. Madrid. España
  • Pani, Manuel; Hospital Reina Sofía. Departamento de Cardiología. Córdoba. España
  • Freixa, Xavier; Hospital Clinic. Departamento de Cardiología. Barcelona. España
  • Trillo-Nouche, Ramiro; Hospital Universitario de Santiago de Compostela. Departamento de Cardiología. Santiago de Compostela. España
Rev. esp. cardiol. (Ed. impr.) ; 75(12): 1001-1010, dic. 2022. tab, graf, ilus
Article in Spanish | IBECS | ID: ibc-212933
Responsible library: ES1.1
Localization: ES15.1 - BNCS
RESUMEN
Introducción y

objetivos:

En insuficiencia cardiaca persistente con insuficiencia mitral (IM) secundaria se debe considerar la reparación transcatéter borde-a-borde (TEER) de la válvula mitral. Los inhibidores de neprilisina (ARNIs) demostraron mejorar el pronóstico en insuficiencia cardiaca. Nuestro objetivo fue evaluar el impacto de los ARNIs en la selección y resultados.

Métodos:

La población del registro nacional de TEER (marzo/2012-enero/2021) se dividió en 2 grupos a) TEER pre-ARNI (n=450) y b) TEER una vez que los ARNIs se recomendaron en guías europeas (n=639), teniendo en cuenta si se prescribieron (n=52) o no (n=587).

Resultados:

Un total de 1.089 pacientes consecutivos se sometieron a TEER para el tratamiento de la IM. Presentaron menor tamaño ventricular izquierdo (100 frente a 82mL, p=0,025) y mejor función (35 frente a 38%, p=0,011) en la era ARNI. A los 2 años, la mortalidad (10,6 frente a 17,3%, p <0,001) y los ingresos por insuficiencia cardiaca (16,6 frente a 27,8%, p <0,001) fueron menores, pero no la recurrencia de IM. En la era ARNI, la mortalidad fue comparable independientemente de la prescripción de ARNIs, pero tuvieron menor tasa de muerte+re-hospitalización a 2 años (OR=0,369, IC95%, 0,137-0,992, p=0,048), mejor NYHA y menor recurrencia de IM (1,9 frente al 14,3%, p=0,011).

Conclusiones:

Se observó una mejor selección y resultados en candidatos a TEER en la era ARNI y su prescripción se asoció a una reducción significativa de eventos globales, mejor NYHA y menor recurrencia de la IM.(AU)
ABSTRACT
Introduction and

objectives:

Transcatheter edge-to-edge repair (TEER) should be considered in patients with heart failure and secondary mitral regurgitation (MR). Angiotensin receptor-neprilysin inhibitors (ARNIs) have been demonstrated to improve prognosis in heart failure. We aimed to evaluate the impact ARNIs on patient selection and outcomes.

Methods:

The population of the Spanish TEER prospective registry (March 2012 to January 2021) was divided into 2 groups a) TEER before the ARNI era (n=450) and b) TEER after the recommendation of ARNIs by European Guidelines (n=639), with further analysis according to intake (n=52) or not (n=587) of ARNIs.

Results:

A total of 1089 consecutive patients underwent TEER for secondary MR. In the ARNI era, there was a reduction in left ventricle dilation (82mL vs 100mL, P=.025), and better function (35% vs 38%, P=.011). At 2 years of follow-up, mortality (10.6% vs 17.3%, P <.001) and heart failure readmissions (16.6% vs 27.8%, P <.001) were lower in the ARNI era, but not recurrent MR. In the ARNI era, 1- and 2-year mortality were similar irrespective of ARNI intake but patients on ARNIs had a lower risk of readmission+mortality at 2 years (OR, 0.369; 95%CI, 0.137-0.992; P=.048), better NYHA class, and lower recurrence of MR III-IV (1.9% vs 14.3%, P=.011).

Conclusions:

Better patient selection for TEER has been achieved in the last few years with a parallel improvement in outcomes. The use of ARNIs was associated with a significant reduction in overall events, better NYHA class, and lower MR recurrence.(AU)
Subject(s)

Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Receptors, Angiotensin / Neprilysin / Heart Failure / Mitral Valve / Mitral Valve Insufficiency Limits: Female / Humans / Male Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2022 Document type: Article Institution/Affiliation country: Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV)/España / Hospital Clinic/España / Hospital Clínico San Carlos/España / Hospital Clínico Universitario de Valladolid/España / Hospital Reina Sofía/España / Hospital Sant Pau/España / Hospital Universitario Central de Asturias/España / Hospital Universitario de Santiago de Compostela/España / Hospital Álvaro Cunqueiro/España
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Receptors, Angiotensin / Neprilysin / Heart Failure / Mitral Valve / Mitral Valve Insufficiency Limits: Female / Humans / Male Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2022 Document type: Article Institution/Affiliation country: Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV)/España / Hospital Clinic/España / Hospital Clínico San Carlos/España / Hospital Clínico Universitario de Valladolid/España / Hospital Reina Sofía/España / Hospital Sant Pau/España / Hospital Universitario Central de Asturias/España / Hospital Universitario de Santiago de Compostela/España / Hospital Álvaro Cunqueiro/España
...