Your browser doesn't support javascript.
loading
Implantes cortos y extracortos e inserción. Estudio retrospectivo con un seguimiento de 1 a 7 años / Short and extra-short implants in the maxilla and mandible with low insertion torque. Retrospective study with a follow-up of 1 to 7 years
Anitua, Eduardo.
Affiliation
  • Anitua, Eduardo; Clínica Eduardo Anitua. Vitoria. España
Cient. dent. (Ed. impr.) ; 20(1): 7-13, feb.-mar. 2023. graf, ilus
Article in Spanish | IBECS | ID: ibc-220168
Responsible library: ES1.1
Localization: ES15.1 - BNCS
RESUMEN

Introducción:

La realización de implantes cortos y extracortos en situaciones de extrema reabsorción maxilar y mandibular supone que la colocación del implante se realiza en condiciones de escaso volumen óseo residual y, por lo tanto. puedeser posible que el torque de inserción que se logre sea menor que en otras situaciones. En el presente artículo se investiga la posible relación que puede tener este bajo torque de inserción con la supervivencia del implante y la pérdida ósea crestal. Material y

método:

Fueron revisadas historias clínicas de forma retrospectivade los implantes insertados en el segundo semestre del año 2015 y primer trimestre del año 2021, para identificar implantes cortos y extracortos con torque de inserción < 20 N/cm. El implante fue la unidadde análisis para la estadística descriptiva en cuanto a la localización, dimensiones del implante, y mediciones radiográficas. El paciente fue la unidad de medida para el análisis de la edad, sexo y la historia médica. Las variables cualitativas se describieron mediante un análisis de frecuencias y las cuantitativas mediante media ydesviación estándar. La supervivencia de los implantes se calculó mediante el método de Kaplan-Meier.

Resultados:

Fueron reclutados 36 pacientes en los que se insertaron 40 implantes que cumplieron los criterios de inclusión marcados para el estudio. El torque de inserción de los implantes reclutados varió entre 5 y 15 Ncm, siendo 5 Ncm en el 37,5% de los casos, 10 Ncm en el 30% de los casos y 15 Ncm en el 32,5 % restante...(AU)
ABSTRACT

Introduction:

The use of short, extrashort implants in situations of extrememaxillary and mandibular resorptionmeans that the implant is placed inconditions of low residual bone volumeand therefore it is possible that theinsertion torque achieved may be lowerthan in other situations. This article investigates the possible relationship thatthis low insertion torque may have with implant survival and crestal bone loss.

Methods:

Medical records of implants inserted in the second half of 2015 and first quarter of 2021 were retrospectively reviewed to identify short, extra-short implants with insertion torque < 20 N/cm.The implant was the unit of analysis for descriptive statistics in terms of location, implant dimensions, and radiographic measurements. The patient was the unit of measurement for the analysis ofage, sex and medical history. Qualitative variables were described by frequency analysis and quantitative variables by mean and standard deviation. Implant survival was calculated using the Kaplan Meier method.

Results:

Thirty-six patients were recruited and 40 implants were inserted that met the inclusion criteria for the study. The insertion torque of the recruited implants...(AU)
Subject(s)

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Dental Implants / Periodontal Attachment Loss / Dental Implantation / Epithelial Attachment Limits: Adult / Aged / Female / Humans / Male Language: Spanish Journal: Cient. dent. (Ed. impr.) Year: 2023 Document type: Article Institution/Affiliation country: Clínica Eduardo Anitua/España
Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Dental Implants / Periodontal Attachment Loss / Dental Implantation / Epithelial Attachment Limits: Adult / Aged / Female / Humans / Male Language: Spanish Journal: Cient. dent. (Ed. impr.) Year: 2023 Document type: Article Institution/Affiliation country: Clínica Eduardo Anitua/España
...