Your browser doesn't support javascript.
loading
Factores que afectan la estabilidad de los implantes dentales según la medición del coeficiente de estabilidad del implante (ISQ). Una revisión sistemática de la literatura / Factors affecting dental implants stability as measured by the implant stability quotient (ISQ). A systematic review of the literature
Chiriboga Malo, José Antonio; Ramírez Freire, Valeria Dennis; Velazco Dávila, Jorge Andrés; Tabares Acevedo, Yancy Alejandra; Moreno Abello, Gloria Cristina.
Affiliation
  • Chiriboga Malo, José Antonio; Universidad San Francisco de Quito. Ecuador
  • Ramírez Freire, Valeria Dennis; Pontificia Universidad Javeriana. Bogotá. Colombia
  • Velazco Dávila, Jorge Andrés; Pontificia Universidad Javeriana. Bogotá. Colombia
  • Tabares Acevedo, Yancy Alejandra; Pontificia Universidad Javeriana. Bogotá. Colombia
  • Moreno Abello, Gloria Cristina; Pontificia Universidad Javeriana. Bogotá. Colombia
Rev. esp. cir. oral maxilofac ; 45(3): 107-120, 2023. tab, graf
Article in Spanish | IBECS | ID: ibc-228814
Responsible library: ES1.1
Localization: ES15.1 - BNCS
RESUMEN
Antecedentes La estabilidad en los implantes dentales colocados en los huesos alveolares es un parámetro importante para el éxito del tratamiento y su oseointegración. Los factores que pueden afectar la estabilidad son densidad ósea, el macrodiseño/microdiseño de los implantes, el diseño quirúrgico, la carga y el sexo; estos se pueden evaluar mediante la obtención de valores del análisis de frecuencia de resonancia (RFA) interpretados como el coeficiente de estabilidad del implante (ISQ).

Objetivo:

Evaluar los factores que pueden afectar la estabilidad de los implantes mediante valores ISQ medidos con el dispositivo Osstell. Materiales y

métodos:

Para esta revisión sistemática se realizó una búsqueda en bases de datos PubMed, Scopus, EBSCO, Science-direct y Cochrane de artículos publicados entre enero del 2015 y diciembre del 2021. Se realizó la elección de estudios clínicos aleatorizados, revisiones sistemáticas y metanálisis basados en el manual de Cochrane. Un total de 26 artículos cumplían con los criterios de inclusión y exclusión.

Resultados:

Fueron evaluados un total de 3047 implantes en 1367 pacientes. Los factores estudiados fueron densidad ósea, macrodiseño/microdiseño del implante, técnica quirúrgica, carga y sexo. La densidad ósea es el factor que más afecta la estabilidad primaria de un implante, mientras que el microdiseño es el factor que más influye para la estabilidad secundaria.

Conclusiones:

Tanto la estabilidad primaria y secundaria de un implante dependen de la interacción de varios factores. Es importante individualizar cada caso y analizar cada uno de los factores con el fin de tomar decisiones acertadas y basadas en evidencia que permitan obtener resultados predecibles. (AU)
ABSTRACT

Background:

Dental implants stability placed on the alveolar ridge is considered an important factor to evaluate the treatment success and its osseointegration. Factors that seem to affect the stability are bone density, implant macro/micro design, surgical protocol, loading and sex. These factors may be evaluated by the measurement of resonance frequency analysis (RFA) resulting as the Implant Stability Quotient (ISQ).

Objective:

To review the literature on the factors that can affect the stability of dental implants considering the ISQ values measured with the Osstell device. Materials and

methods:

A systematic search of the literature was carried out in the following databases PubMed, Scopus, EBSCO, Science direct y Cochrane of articles published between January 2015 and December 2021. Randomized controlled trials, systematic reviews and metanalysis were selected based on the Cochrane handbook for systematic reviews. A total of 26 articles were selected and analyzed based on our inclusion and exclusion criteria.

Results:

In the 26 articles selected, 3047 implants were evaluated placed in 1367 patients. The most studied factors were bone density, implant macro design, implant micro design, surgical technique, implant loading and genre. Bone density is the factor that influence the most when studying primary stability. For secondary stability, implant micro design has a direct relationship according to resonance frequency analysis (RFA).

Conclusions:

Primary and secondary stability depends on many factors. It is important to individualize each patient and evaluate each factor for decision making based on evidence and have a more predictable outcome when placing dental implants. (AU)
Subject(s)


Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Dental Implants / Denture Retention Limits: Humans Language: Spanish Journal: Rev. esp. cir. oral maxilofac Year: 2023 Document type: Article Institution/Affiliation country: Pontificia Universidad Javeriana/Colombia / Universidad San Francisco de Quito/Ecuador

Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Dental Implants / Denture Retention Limits: Humans Language: Spanish Journal: Rev. esp. cir. oral maxilofac Year: 2023 Document type: Article Institution/Affiliation country: Pontificia Universidad Javeriana/Colombia / Universidad San Francisco de Quito/Ecuador
...