Monitorización intratraqueal de gases en anestesia / Intratracheal gases monitoring in anaesthesia
Actual. anestesiol. reanim
; 18(2): 41-45, abr.-jun. 2008.
Article
in Es
| IBECS
| ID: ibc-67330
Responsible library:
ES15.1
Localization: ES15.1 - BNCS
RESUMEN
Los avances tecnológicos en el análisis de gases y su incorporación a todas las máquinas actuales de anestesia han permitido la monitorización de los agentes halogenados en la anestesia inhalatoria. El primer descubrimiento de la monitorización intratraqueal encontró que el ETCO2 intratraqueal era muy similar a los valores alveolares de ETCO2 porque sus valores eran casi los mismos que los valores arteriales. Además estos eran diferentes a los valores extratraqueales aunque existía una buena correlación. Sin embargo, las diferencias intra- y extratraqueales de los gases halogenados y el N2O no fueron estudiados. Recientemente se han descubierto diferencias significativas en la monitorización intratraqueal de gases. Este tipo de monitorización puede ser muy útil en el futuro en pacientes críticos, pediátricos y ofrecer un buen control del Et de los vapores halogenados cuando no se dispone de sistemas de monitorización de hipnosis. Son analizadas las ventajas e inconvenientes de este tipo novedoso de monitorización intratraqueal con un prometedor futuro (AU)
ABSTRACT
Technology advantages in gases analyse and their supply inmost anaesthesia machines have improved halogenated agents monitoring in inhaled anaesthesia. The first discovering about endotracheal monitoring found intratracheal ETCO2 were very similar to alveolar ETCO2 because their values were almost the same to arterial values. Moreover these ones are different to extratracheal values but there were good correlation level. However, intra and extratracheal differences of halogenated gases and N2O were not studied. Lately, it has discovered significant differences in intratracheal gases monitoring during paediatric anaesthesia. This kind of monitoring can be very useful in the future in critical, paediatric patients and offers a good control of Et halogenated vapors when we dont have hypnosis monitoring. Advantages and disadvantages are studied of this new intratracheal monitoring system with a promised future (AU)
Search on Google
Collection:
National databases
/
Spain
Database:
IBECS
Main subject:
Monitoring, Intraoperative
/
Anesthesia, Inhalation
/
Anesthesia, Endotracheal
Limits:
Humans
Language:
Spanish
Journal:
Actual. anestesiol. reanim
Year:
2008
Document type:
Article
Institution/Affiliation country:
Hosiptal General Universitario Gregorio Marañón/España
/
Hospital Infanta Leonor/España
/
Hospital Infanta Sofía/España
/
Universidad Autónoma de Madrid/España