Estudio experimental sobre la repercusión anatómica de la zónula de Zinn tras la introducción de un anillo endocapsular en ojos de cerdo / Anatomical repercusion on the zonular apparatus after a capsular tension ring insertion in swine eyes
Colomé-Campos, J; Ortega-Usobiaga, J; Shahin, M; Forcadell, M; Pino, A; Forteza, T; Baubí, C.
Affiliation
  • Colomé-Campos, J; Hospital de Tortosa Verge de la Cinta. Tortosa. España
  • Ortega-Usobiaga, J; Clínica Baviera. Bilbao. España
  • Shahin, M; Hospital de Tortosa Verge de la Cinta. Tortosa. España
  • Forcadell, M; Hospital de Tortosa Verge de la Cinta. Tortosa. España
  • Pino, A; Hospital de Tortosa Verge de la Cinta. Tortosa. España
  • Forteza, T; Hospital de Tortosa Verge de la Cinta. Tortosa. España
  • Baubí, C; Hospital de Tortosa Verge de la Cinta. Tortosa. España
Arch. Soc. Esp. Oftalmol ; 83(10): 589-594, oct. 2008. ilus
Article in Es | IBECS | ID: ibc-68073
Responsible library: ES15.1
Localization: ES15.1 - BNCS
RESUMEN

Objetivos:

Valorar experimentalmente la integridad morfológica de los ligamentos suspensorios de la zónula de Zinn (LSZZ) tras la introducción de un anillo de distensión capsular (ADC) mediante un estudio descriptivo.

Métodos:

Se utilizaron siete ojos de cerdo a los cuales se realizó una extracción extracapsular de cristalino transparente. A cuatro se introdujo un ADC con pinzas y al quinto con inyector. Los otros dos se utilizaron como control. Se examinó la integridad anatómica y la nueva configuración de los LSZZ con un microscopio electrónico de barrido.

Resultados:

No se observaron alteraciones en la integridad de los LSZZ. Los LSZZ adoptan tras la introducción de un ADC una nueva trayectoria de repliegue consecuencia de la nueva disposición del saco capsular.

Conclusiones:

En un modelo experimental conojos de cerdo no se encontraron lesiones en los LSZZ por lo que parece que, en cápsulas elásticas y de gran diámetro, la inserción de un ADC no produce roturas en los LSZZ
ABSTRACT

Purpose:

To carry out an experimental and descriptive study that exhibits the anatomical repercussions on the zonular apparatus after a capsular tensionring (CTR) is inserted.

Methods:

CTRs were inserted in five swine eyes (four with forceps, one with an injector). Two additional eyes were left untouched for control purposes.The integrity of the suspensory ligament was examined by scanning electron microscopy.

Results:

We did not observe alterations in the integrity of the zonular apparatus. The suspensory ligaments adopted a new fold configuration.

Conclusions:

CTR insertion is a safe therapeutic tool to maintain the integrity of the lens zonules inelastic, large diameter capsular bags
Subject(s)
Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Swine / Microscopy, Electron, Scanning / Models, Animal / Lens Capsule, Crystalline / Lens, Crystalline / Ocular Physiological Phenomena Limits: Animals Language: Spanish Journal: Arch. Soc. Esp. Oftalmol Year: 2008 Document type: Article Institution/Affiliation country: Clínica Baviera/España / Hospital de Tortosa Verge de la Cinta/España
Full text: Available Collection: National databases / Spain Database: IBECS Main subject: Swine / Microscopy, Electron, Scanning / Models, Animal / Lens Capsule, Crystalline / Lens, Crystalline / Ocular Physiological Phenomena Limits: Animals Language: Spanish Journal: Arch. Soc. Esp. Oftalmol Year: 2008 Document type: Article Institution/Affiliation country: Clínica Baviera/España / Hospital de Tortosa Verge de la Cinta/España
...