Your browser doesn't support javascript.
loading
Registro Español de Marcapasos. VI Informe Oficial de la Sección de Estimulación Cardiaca de la Sociedad Española de Cardiología (2008) / Spanish Pacemaker Registry. 6th Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2008)
Coma Samartín, Raúl; Martínez Ferrer, José; Sancho-Tello de Carranza, María José; Ruiz Mateas, Francisco; Leal del Ojo González, Juan.
Affiliation
  • Coma Samartín, Raúl; Hospital 12 de Octubre. Madrid. España
  • Martínez Ferrer, José; Hospital Txagurritxu. Vitoria. España
  • Sancho-Tello de Carranza, María José; Hospital Universitario La Fe. Valencia. España
  • Ruiz Mateas, Francisco; Hospital Costa del Sol. Málaga. España
  • Leal del Ojo González, Juan; Hospital Nuestra Señora de Valme. Sevilla. España
Rev. esp. cardiol. (Ed. impr.) ; 62(12): 1450-1463, dic. 2009. tab, ilus
Article in Spanish | IBECS | ID: ibc-75302
Responsible library: ES1.1
Localization: BNCS
RESUMEN
Introducción y objetivos. En este artículo se describe el resultado del análisis de los implantes y recambios de marcapasos remitidos en 2008 al Registro Español de Marcapasos. Métodos. La recogida de datos se basa en la información de la Tarjeta Europea del Paciente Portador de Marcapasos. Resultados. Se recibió información de 116 centros hospitalarios, con un total de 11.855 tarjetas que suponen el 36,3% de los marcapasos implantados. Se objetiva un notable aumento del número de unidades consumidas, alcanzando 708,3 por millón de habitantes. Existe una mayor incidencia de implantes de marcapasos y a una media de edad más baja en varones, correspondiendo a la década de los setenta el mayor número de implantes, con el 39,1% del total. Los bloqueos auriculoventriculares aparecen como la más frecuente de las indicaciones electrocardiográficas. En los cables utilizados, el empleo del sistema de fijación activa supone el 59,3% de los auriculares y el 37% de los ventriculares. Se observa una mejor selección del modo de estimulación, siendo la edad un factor determinante, como por ejemplo en la enfermedad del nódulo sinusal, en la que se utiliza el modo VVI/R en el 29% de pacientes mayores de 80 años frente al 14% en los de edad inferior. Conclusiones. La edad es un factor que se muestra influyente en la adecuación del modo de estimulación. Aumenta la selección del sistema de fijación activa, alcanzando el 44,5% de los cables utilizados. La estimulación auriculoventricular registra el más alto porcentaje de utilización de todos los años analizados (AU)
ABSTRACT
Introduction and objectives. This article describes the findings of an analysis of data on pacemaker implantations and replacements reported to the Spanish Pacemaker Registry during 2008. Methods. The data came primarily from information recorded on European Pacemaker Patient Identification Cards. Results. Data were received from 116 hospital units, which submitted a total of 11,855 identification cards representing 36.3% of all pacemakers implanted. There was a marked increase in the number of pacemaker units used, which rose to a rate of 708.3 per million inhabitants. The frequency of pacemaker implantation increased and the mean age of male patients decreased. The largest number of implantations were carried out in patients in their 70s, who comprised 39.1% of the total. The most frequent electrocardiographic indication was atrioventricular block. With regard to pacing leads, active fixation leads were used in the atrium in 59.3% of cases and in the ventricle in 37.9% of cases. There was an improvement in the choice of pacing mode, with age being a determining factor. For example, in sick sinus syndrome, the VVI/R mode was used in a 29% of patients aged over 80 years compared with 14% of those aged under 80 years. Conclusions. Age was found to be one factor influencing the selection of the most appropriate pacing mode. Active fixation leads were used more often, reaching 44.5% of leads implanted. Atrioventricular pacing was used in a greater percentage of cases than in any other time period covered by the pacemaker registry (AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Pacemaker, Artificial / Diseases Registries / Atrioventricular Block Type of study: Prognostic study Limits: Humans Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2009 Document type: Article Institution/Affiliation country: Hospital 12 de Octubre/España / Hospital Costa del Sol/España / Hospital Nuestra Señora de Valme/España / Hospital Txagurritxu/España / Hospital Universitario La Fe/España
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Pacemaker, Artificial / Diseases Registries / Atrioventricular Block Type of study: Prognostic study Limits: Humans Language: Spanish Journal: Rev. esp. cardiol. (Ed. impr.) Year: 2009 Document type: Article Institution/Affiliation country: Hospital 12 de Octubre/España / Hospital Costa del Sol/España / Hospital Nuestra Señora de Valme/España / Hospital Txagurritxu/España / Hospital Universitario La Fe/España
...