Cambios en el espesor de la capa de fibras nerviosas tras cirugía de cataratas medidos con OCT: un estudio piloto / Retinal nerve fiber layer changes after cataract surgery measured by OCT: a pilot study
Arch. Soc. Esp. Oftalmol
; 84(6): 305-310, jun. 2009. tab
Article
in Es
| IBECS
| ID: ibc-75598
Responsible library:
ES1.1
Localization: BNCS
RESUMEN
Objetivos: Analizar cambios en el espesor de lacapa de fibras nerviosas de la retina (CFNR) peripapilartras cirugia de cataratas.Metodos: Medicion del espesor medio de laCFNR de pacientes sometidos a cirugia de cataratasutilizando tomografia de coherencia optica(OCT) III StratusR antes de la cirugia, un dia despuesde la intervencion y transcurrido un mes. Losdatos fueron analizados mediante el programainformatico SPSS 12.0. Los resultados fueroncomparados empleando el test pareado de doscolas t de Student.Resultados: El grupo de estudio estaba compuestode 74 ojos de 74 pacientes. El espesor medio de laCFNR antes de la cirugia de cataratas (AVGT0) fue90,71 Êm (DE: 19,93), el dia despues de la cirugia(AVGT1) fue 88,30 Êm (DE: 20,59); y un mes despues(AVGT2) 97,45 Êm (DE: 14,30). No se encontrarondiferencias estadisticamente significativasentre AVGT0 y AVGT1 (P=0,37); sin embargo,dicha diferencia si se encontro entre AVGT1 yAVGT2 (P= 0,002). Tambien se encontro diferenciaestadísticamente significativa en la calidad de señalde la señal entre AVGT0 y AVGT2 (P=0,0001).Conclusiones: El espesor medio de la capa defibras nerviosas experimenta un incremento cuandoes medido mediante OCT III Stratus® un mes tras lacirugía de cataratas. Este fenómeno se acompaña deuna mejoría en la calidad de la señal(AU)
ABSTRACT
Purpose: To analyze changes in peripapillary retinalnerve fiber layer (RNFL) after cataract surgery.Methods: The average RFNL thickness of patientswho underwent cataract surgery was measuredusing the optical coherence tomography (OCT) IIIStratusR before surgery, the day after and onemonth later. The data were analyzed using the SPSS12.0 software. We used paired two tail studentLs ttest for comparisons.Results: The study group was composed by 74 eyesof 74 patients. The RNFL thickness average was90.71 Êm (SD: 19.93), 88.30 Êm (SD: 20.59) and97.45 Êm (SD: 14.30), before cataract surgery(AVGT0), the day after surgery (AVGT1) and onemonth later (AVGT2) respectively. We did not findstatistically significant difference between AVGT0and AVGT1 (P=0.37); however, statistically significantdifference between AVGT1 and AVGT2 (P=0.002) as well as in the image signal quality betweenAVGT0 and AVGT2 (P= 0.0001).Conclusions: The RNFL average thickness measuredby OCT III StratusR showed an increase one month after cataract surgery. This phenomenon isaccompanied with an improvement in signal quality(AU)
Full text:
1
Collection:
06-national
/
ES
Database:
IBECS
Main subject:
Optic Nerve
/
Cataract
/
Cataract Extraction
/
Glaucoma
/
Tomography, Optical Coherence
Type of study:
Observational_studies
/
Prognostic_studies
Limits:
Adolescent
/
Adult
/
Aged
/
Child
/
Child, preschool
/
Female
/
Humans
/
Male
Language:
Es
Journal:
Arch. Soc. Esp. Oftalmol
Year:
2009
Document type:
Article