Your browser doesn't support javascript.
loading
Resonancia magnética cardíaca de las cardiopatías congénitas en el adulto / Diffusion-weighted whole-body MRI (virtual PET) in screening for osseous metastases
Bastarrika Alemañ, G; Gavira Gómez, J. J; Zudaire Díaz-Tejeiro, B; Castaño Rodríguez, S; Romero Ibarra, C; Sáenz de Buruaga, J. D.
Affiliation
  • Bastarrika Alemañ, G; Universidad de Navarra. Clínica Universitaria. Pamplona. España
  • Gavira Gómez, J. J; Universidad de Navarra. Clínica Universitaria. Pamplona. España
  • Zudaire Díaz-Tejeiro, B; Universidad de Navarra. Clínica Universitaria. Pamplona. España
  • Castaño Rodríguez, S; Universidad de Navarra. Clínica Universitaria. Pamplona. España
  • Romero Ibarra, C; Hospital Virgen del Camino. Pamplona. España
  • Sáenz de Buruaga, J. D; Universidad de Navarra. Clínica Universitaria. Pamplona. España
Radiología (Madr., Ed. impr.) ; 49(6): 397-405, nov. 2007.
Article in Spanish | IBECS | ID: ibc-78993
Responsible library: ES1.1
Localization: BNCS
RESUMEN
Objetivo. Presentar nuestra experiencia preliminar en resonancia magnética de cuerpo entero (RMCE) en el cribado de metástasis óseas, añadiendo la secuencia de difusión de todo el cuerpo. Material y métodos. Veinticuatro pacientes con neoplasias malignas fueron estudiados con gammagrafía ósea (GO) y RM de cuerpo entero añadiendo secuencia de difusión. La RMCE se realizó con un equipo de 1.5 T en 3 estaciones en el plano coronal FSE T1 y STIR y plano sagital FSE T1 del raquis. Se añadió la secuencia de difusión (b 600 s/mm2) de RMCE en el plano axial en 5 estaciones diferentes y presentación iconográfica en reconstrucción en el plano coronal con inversión del contraste para obtener una imagen similar a la de la tomografía por emisión de positrones (PET) (PET virtual). Los hallazgos de la GO y la RM fueron comparados para la existencia o no de metástasis óseas, valorando al paciente tanto globalmente como por regiones óseas. Las lesiones metastásicas se confirmaron por biopsia o seguimiento en 6-8 meses Resultados. Globalmente, la RMCE con difusión fue superior a la GO, sensibilidad 100% (GO 71%), especificidad 90% (GO 80%) y fiabilidad 96% (GO 75%). Valorando por regiones óseas, la RM tuvo también unos resultados superiores a la GO sensibilidad 96% (GO 52%). En difusión las metástasis líticas fueron hiperintensas en todos los casos, con un valor ADC superior al hueso sano pero inferior a las lesiones con edema agudo de etiología benigna. La RMCE mostró, además, hallazgos extraóseos desconocidos relacionados con el tumor y en un 42% de los pacientes metástasis extraóseas. Conclusiones. La RMCE añadiendo la secuencia de difusión es un método eficaz para detectar metástasis óseas con fiabilidad superior a la gammagrafía; aportando además información sobre lesiones extraóseas. Las metástasis líticas se comportan de forma hiperintensa en difusión y tienen un valor ADC inferior al edema benigno (AU)
ABSTRACT
Objective. To present our preliminary experience in whole-body MRI with an added diffusion-weighted sequence in screening for osseous metastases. Material and methods. 24 patients with malignant neoplasms underwent bone scintigraphy and whole-body MRI with the addition of a diffusion-weighted sequence. Whole-body MRI was performed on a 1.5 T unit using a three-station protocol; coronal T1-weighted FSE and STIR sequences and sagittal T1-weighted FSE of the spine were acquired. A diffusion-weighted sequence (b 600 s/mm2) was added in the axial plane at five different stations and iconographic presentation in coronal-plane reconstructions with contrast inversion was used to obtain an image similar to that provided by PET (virtual PET). The findings at bone scintigraphy (BS) and MRI were compared for the presence of osseous metastases, evaluating the results for each patient both globally and for different osseous regions. Metastatic lesions were confirmed by biopsy or by six to eight months' follow-up. Results. Globally, whole-body MRI with diffusion-weighted sequences was superior to bone scintigraphy, with a sensitivity of 100% (BS 71%), specificity 90% (BS 80%), and reliability 96% (BS 75%). In the evaluation by osseous region, the results of MRI were also better than those of bone scintigraphy sensitivity 96% (BS 52%). In the diffusion-weighted sequence, lytic metastases were hyperintense in all cases, with an apparent diffusion coefficient (ADC) value higher than normal bone but lower than lesions with acute edema of benign etiology. Whole-body MRI also revealed unknown extraosseous findings related to the tumors and extraosseous metastases in 42% of the patients. Conclusions. Whole-body MRI with an added diffusion-weighted sequence is an efficacious method of detecting osseous metastases and is more reliable than bone scintigraphy. Moreover, whole-body MRI provides information about extraosseous lesions. Lytic metastases are hyperintense in diffusion-weighted sequences and have a lower ADC than benign edema (AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Aortic Valve Stenosis / Tetralogy of Fallot / Magnetic Resonance Imaging / Clinical Protocols / Constriction, Pathologic / Heart Defects, Congenital Type of study: Diagnostic study / Practice guideline / Screening study Limits: Adult / Female / Humans / Male Language: Spanish Journal: Radiología (Madr., Ed. impr.) Year: 2007 Document type: Article Institution/Affiliation country: Hospital Virgen del Camino/España / Universidad de Navarra/España
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Aortic Valve Stenosis / Tetralogy of Fallot / Magnetic Resonance Imaging / Clinical Protocols / Constriction, Pathologic / Heart Defects, Congenital Type of study: Diagnostic study / Practice guideline / Screening study Limits: Adult / Female / Humans / Male Language: Spanish Journal: Radiología (Madr., Ed. impr.) Year: 2007 Document type: Article Institution/Affiliation country: Hospital Virgen del Camino/España / Universidad de Navarra/España
...