Your browser doesn't support javascript.
loading
PET-TAC: captación pulmonar focal de FDG sin alteracion estructural en TAC / PET/CT: Focal lung uptake of 18F-fluordeoxiglucose on PET but no structural alterations on CT
Sánchez-Sánchez, R; Rodríguez-Fernández, A; Ramírez-Navarro, A; Gómez-Río, M; Ramos-Font, C; Llamas-Elvira, J. M.
Affiliation
  • Sánchez-Sánchez, R; Hospital Universitario Virgen de las Nieves. Granada. España
  • Rodríguez-Fernández, A; Hospital Universitario Virgen de las Nieves. Granada. España
  • Ramírez-Navarro, A; Hospital Universitario Virgen de las Nieves. Granada. España
  • Gómez-Río, M; Hospital Universitario Virgen de las Nieves. Granada. España
  • Ramos-Font, C; Hospital Universitario Virgen de las Nieves. Granada. España
  • Llamas-Elvira, J. M; Hospital Universitario Virgen de las Nieves. Granada. España
Rev. esp. med. nucl. (Ed. impr.) ; 29(3): 131-134, mayo-jun. 2010. ilus
Article in Spanish | IBECS | ID: ibc-79413
Responsible library: ES1.1
Localization: BNCS
RESUMEN
La combinación de la tomografía por emisión de positrones (PET) y la tomografía computarizada (TAC) en un único equipo (PET/TAC) supone una potente herramienta diagnóstica que abre nuevos horizontes en el diagnóstico por imagen. Para la correcta interpretación de los estudios PET/TAC, es necesario conocer la biodistribución de la 18F-fluorodeoxiglucosa, las variables fisiológicas así como los posibles artefactos ante los que nos podemos encontrar. Presentamos cuatro casos en los cuales en el contexto de seguimiento/diagnóstico de un proceso oncológico se realiza un estudio 18F-fluorodeoxiglucosa-PET/TAC. Dicho estudio mostró en todos los casos captación focal en el parénquima pulmonar en el estudio de la PET en ausencia de alteraciones estructurales en las imágenes de la TAC. La extravasación de radiotrazador en tres de ellos así como una modificación reciente de la técnica de inyección utilizada hicieron pensar en la existencia de un artefacto responsable de dichas discordancias(AU)
ABSTRACT
The combination of positron emission tomography (PET) and computed tomography (CT) in a single device (PET/CT) offers a powerful diagnostic tool that opens up new horizons for imaging diagnosis. In order to correctly interpret PET/CT studies, knowledge of the biodistribution of 18F-fluorodeoxyglucose (FDG), the physiological variants as well as the pitfalls, including artefacts, which may be found, is necessary. We report four cases performed during the follow-up diagnostic context of an oncology study performed with 18F-FDG-PET/CT. In every case, this study showed focal uptake in the lung parenchyma in the PET study with no structural lesions being found on the CT scan. Radiotracer extravasation in three of these patients and a recent change in the injection protocol used suggest that an artefact was responsible for these discrepancies(AU)
Subject(s)
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Tomography, X-Ray Computed / Fluorodeoxyglucose F18 / Positron-Emission Tomography Type of study: Diagnostic study / Practice guideline Limits: Adult / Aged / Female / Humans / Male Language: Spanish Journal: Rev. esp. med. nucl. (Ed. impr.) Year: 2010 Document type: Article Institution/Affiliation country: Hospital Universitario Virgen de las Nieves/España
Search on Google
Collection: National databases / Spain Database: IBECS Main subject: Tomography, X-Ray Computed / Fluorodeoxyglucose F18 / Positron-Emission Tomography Type of study: Diagnostic study / Practice guideline Limits: Adult / Aged / Female / Humans / Male Language: Spanish Journal: Rev. esp. med. nucl. (Ed. impr.) Year: 2010 Document type: Article Institution/Affiliation country: Hospital Universitario Virgen de las Nieves/España
...